Laserfiche WebLink
BOOTH EXTERIOR BOOTH INTERIOR <br /> BOOTH INTERIOR BOOTH EXTERIOR <br /> � — BOOTH INTERIOR BOOTH EXTERIOR HEADER GIRT, PER STRUCTURAL 4"THERMALSAFE METAL PANEL <br /> 4" THERMALSAFE METAL PANEL � �--r HEADER GIRT, PER STRUCTURAL _ <br /> � 4"THERMALSAFE METAL PANEL � �-- HEADER GIRT, PER STRUCTURAL COLUMN (BEYOND), PER STRUCTURAL THERMALSAFE METAL PANEL GORNER <br /> THERMALSAFE METAL PANEL � ( � COLUMN (BEYOND), PER STRUCTURAL � � � EDGE TRIM, PER MANUFACTURER <br /> EDGE TRIM, PER MANUFACTURER THERMALSAFE METAL PANEL COLUMN (BEYOND), PER STRUCTURAL THERMALSAFE <br /> � - � STEEL PLATE WELDED TO CHANNEL EDGE TRIM, PER MANUFACTURER METAL PANEL <br /> SECURE BOTH FRAMES INTO GIRT, PER STRUCTURAL I CORNER EDGE TRIM, <br /> STEEL PLATE W/ HARDWARE � � SEAL FRAME ALL AROUND PER MANUFACTURER —��� <br /> FROM WINDOW MANUFACTURER ---��\ � JAMB GIRT, PER STRUCTURAL REFER � � � i-f- _ <br /> TO ELEVATIONS FOR LOCATIONS DOOR SLAB AND FRAME, ; ' <br /> TGP DESIGNER SERIES FRRME W/ , � PER SCHEDULE 4 a . � <br /> �, - � <br /> 3/16" STANDARD FIRELITE OV�R ;' � I TGP DESIGNER SERiES FRAMES W/ 1/4° �\ � A <br /> �� P P G S O L A R B A N 6 0 L O W-E T E M P E R E D <br /> 3/16° STANDARD FIRELITE � � � � <br /> INSULATED GLASS UNIT (IGU) ; i - } GLASS OVER 1/4"CLEAR TEMPERED '� <br /> ', , I ( INSULATED GLASS UNIT (IGU) <br /> �� i <br /> P2P - BOOTH WINDOW - HEAD � P2P - BOOTH DOOR HEAD �. P2P - BOOTH H4SE REEL HEAD 7 <br /> SCALE: 1 1/2" = 1'-0° A600-22 A600-7� SCALE: 1 1/2° = 1'-0° <br /> A600-71 SCALE: 1 1/2"= 1'-0" A600-22 A600-71 <br /> BOOTH EXTERIOR BOOTH INTERIOR <br /> BOOTH INTERIOR BOOTH EXTERIOR <br /> BOOTH INTERIOR BOOTH EXTERIOR JAMB GIRT, PER STRUCTURAL. REFER 4"THERMALSAFE METAL PANEL <br /> 4" THERMALSAFE METAL PANEL JAMB GIRT, PER STRUCTURAL. REFER TO ELEVATIONS FOR LOCATIONS � <br /> � TO ELEVATIONS FOR LOCATIONS 4° THERMALSAFE METAL PANEL r STRUCTURAL GIR7, PER STRUCTURAL �� I � THERMALSAFE METAL PRNEL CORNER <br /> THERMALSAFE METAL PANEL � I —� THERMALSAFE METAL � EDGE TRIM, PER MANUFACTURER <br /> EDGE TRIM, PER MANUFACTURER i STEEL PLATE WELDED TO CHANNEL � PANEL CORNER EDGE \ <br /> THERMALSAFE METAL PANEL � - JAMB GIRT, PER STRUCTURAL. REFER TRIM, PER � <br /> � GIRT, PER STRUCTURA� EDGE TRIM, PER MANUFACTURER TO ELEVATIONS FOR LOCATIONS MANUFACTURER <br /> SECURE BOTH FRAMES INTO � ���� <br /> STEEL PLATE W/ HARDWARE STRUCTURAL GIRT, PER STRUCTURAL SEAL FRAME A�L AROUND �, � STEEL PLATE WELDED TO CHANNEL <br /> FROM WINDOW MANUFACTURER —�,�\ � �� _ GIRT, PER STRUCTURAL <br /> - TGP DESIGNER SERIES FRAMES W/1/4° �OOR SLAB AND FRAME, a. . - � <br /> PPG SOLARBAN 60 LOW-E TEMPERED PER SCHEDULE ° - � � <br /> TGP DESIGNER SERIES FRAME W/ , i ; GLASS C7VER 1/4" CLEAR TEMPERED \\ - ° - � <br /> 3/16° STANDARD FIRELITE OVER ; i � <br /> I INSULATED GLASS UNIT (�GU) .� <br /> 3/16"STANDARD FIRELITE , ' I � i � � <br /> WSULATED GLASS UNIT (IGU) ; ; � � ; <br /> ! <br /> P2P - BO�TH WIND�W - JAMB 2 P2P - BOOTH DODR JAMB 6 P2P - BOOTH HOSE REEL JAMB 8 <br /> SCALE: 1 1/2" = 1'-0° A600-72 A600-71 SCALE: 1 1/2" = 1'-0" A600-71 SCALE: 1 1/2"= 1'-0" A600-71 <br /> BOOTH INTERIOR BOOTH EXTERIOR BOOTH INTERIOR BOOTH EXTERIOR BOOTH EXTERIOR BOOTH INTERIOR <br /> � � DOOR SLAB AND FRAME, COLUMN (BEYOND), PER THERMALSAFE - 4"THERMALSAFE METAL PANEL <br /> - TGP DESIGNER SERIES FRAME W/ I � I TGP DESIGNER SERIES FRAMES W/ 1/4° <br /> PER SCHEDULE STRUCTURAL METAL PANEL <br /> 3/16" STANDARD FIRELITE OVER ; PPG SOLARBAN 60 LOW-E TEMPERED —� I <br /> 3/16"STANDARD FIRELITE '; ; � � GLASS OVER 1/4"CLEAR TEMPERED \� CORNER EDGE TRIM, THERMALSAFE METAL PANEL CORNER <br /> INSULATED GLASS UNIT IGU ' � WSULATEp GLASS UNIT IGU DOOR THRESHOLD �� ' CONCRETE SLAB, PER STRUCTURAL PER MANUFACTURER -- / <br /> � � � ) `� ; , T- -r EDGE TRIM, PER MANUFACTURER <br /> � <br /> SECURE BOTH FRAMES INTO i JAMB GIRT, PER STRUCTURAL. REFER STEEL ANGLE, PER STRUCTURAL ' - <br /> TO ELEVATIONS F�R LOCATIONS <br /> STEEL PLATE W/ HARDWARE ( <br /> FROM WINDOW MANUFACTURER STEEL PLATE WELDED TO CHANNEL. SLOPEQ CONCRETE SLAB, ; <br /> ��� � � GIRT, PER STRUCTURAL PER STRUCTURAL � � <br /> THERMALSAFE METAL PANEL R,,_4 G. ;.; ., ^ . , .. I <br /> EDGE TRIM, PER MANUFACTURER i �� ' - .. =°" a-' ' ;' . .a, :° : , =d- <br /> � I �`� STRUCTURAL GIRT, PER STRUCTURAL , a ,-� � .' � �a� �° °� `� �-pv.'._. °e . - � a: v . �a _ �=" � ;�° COLUMN (BEYOND), PER STRUCTURAL - <br /> � � a .° . �'.-. a .. <br /> 4"THERMALSAFE METAL PANEL '"d G�� '.� - . - : - � . d -° ` " , -� " -" a =a ,." - ` <br /> � �— COLUMN (BEYOND}, PER STRUCTURAL ' . � x-. � ad-�,4�o,�._9�_ c- - � � �.-��.I�- � ° , °�: `°� a°�_,��� ;--� HEADER GIRT, PER STRUCTURAL <br /> I I I ' , .- , ' A ' , , - , <br /> __ _ , , A . . <br /> . . ,Q , ; G ; . . _ e. � . `a •. .. 'q ' . <br /> a�. <br /> P2P - BOOTH WINDCJW - SILL 3 P2P - BOOTH DOOR THRESHOLD 5 P2P - B40TH HOSE REEL SILL 9 <br /> SCALE: 1 1/2" = 1'-0" A600-22 A600-71 SCALE: 1 1/2" = 1'-0" A600-71 SCALE: 1 1!2"= 1'-0" A600-22 A600-71 <br /> . <br /> BOOTH INTERIOR <br /> THERMALSAFE METAL PANEL <br /> EDGE TRIM, PER MANUFACTURER � <br /> BOOTH INTERIOR BOOTH EXTERIOR BOOTH INTERIOR <br /> 5 1 " <br /> THRU WALL BOLTS � �� <br /> _ THERMALSAFE METAL PANEL _� <br /> � � EDGE TRlM, PER MANUFACTURER �� <br /> THERMALSAFE METAL �'�_ � - <br /> PANEL EDGE TRIM, PER ,�� ; _ � _ 18 GA. INTERIOR CHANNEL �� p�R <br /> MANUFACTURER - � =' � �/� �R <br /> ` ' `r PERIMETER OF PANEL BINDER <br /> 'v -r � � <br /> rn � _`- <br /> � 14 GA. CAPPING CHANNEL <br /> � - � � 3 PERIMETER QF DOOR BOOTH EXTERIOR <br /> SLIDING DOOR, PER — P�P - S L I D I N� D00 R JAM B 2 <br /> SCHEDULE —�,` FRONT BINDER CORE ,)2 <br /> � SCALE: 1 1/2"= 1'-0" <br /> — BOX TRACK BOOTH EXTERIOR A600-71 <br /> � <br /> i �\670 REGISTERED <br /> ARCHITECT <br /> . . � Pa'ter'Lago a�ino <br /> P2P - SLIDING DOQR HEAD �o P2P - SLIDING DOOR JAMB 1 � � � �'� P ���N�1,�" <br /> SCALE: 1 1/2" = 1'-0° A600-71 SCALE; 1 1/2" = 1'-0° . STATE O WA INGTON <br /> A600-71 900 SW 1 bth Street Su1te 307 <br /> -�------__— <br /> Renton, Washington 98057 � <br /> � <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 'N A s`\ ACCEPTABILITY °�'WN DATE SUBTITLE CURRENT REVISION SYMBOL DATE ,��, <br /> �`� �E —y'^�� CNECKED 12l22115 W2548317 12/22/15 �'. <br /> 0 ISSUEFORCONSTRUCTION CXJ PJL 12i22/15 P r THISDESIGNANDIOR DETAILS - P2P PAINT OPERATIONS O � <br /> � � � SPECIFICATION IS APPROVED <br /> PJL �ZIZZI'I 5 SHEET u, <br /> � �� O 6RPHARCHITECTS - ENGINEER TITLE BOEING 777X CWC BUILDING � <br /> A600 7 � N <br /> ENciNEERSINc. APPROVED BY DEPT. DATE PJL 12/22J15 0 <br /> No.31s1 CHECKED � N <br /> `� BUILDING 40-58 <br /> �P�`�� o APPROVED JOB NO. COMP NO. � <br /> � ��qT�— ��tiP�` 40-58-A600-71 � <br /> -- �E OF AUTN� APPROVED ARCHITECTURAL MASTER EVERETT, WA owc No. 40-58-A600-71 <br />