Laserfiche WebLink
� i Buiiding Control System Point Summary Buiiding Control System Point Summary <br /> �` System Name: Qty. System Name: qty; <br /> Process Exhaust Fan 2 Paint Mixing, Primer/Paint Storage 5 <br /> Description: anaiog Description: ana►o � <br /> Inputs Analog Outputs Digital inputs Digital Outputs Network Alarms R@111aCkS lnputs Analog Outputs Digital lnputs Digital Outputs Network Alarms Remarks <br /> Typical of Each Typical of Each <br /> Exhaust Fan Sta�/Stop 4 Room Temperature � <br /> Sensor <br /> Exhaust Fan Proof 4 4 Current Sensing <br /> Relay Room Occupancy Sensor 1 <br /> Speed, plus add'I info <br /> Exhaust Fan VSD 4 4 4 via gateway • <br /> Exhaust Airflow Monitoring 4 System Name: Qty: <br /> Unit . <br /> General Exhaust Fan 2 : <br /> Exhaust Air Temperature 1 <br /> Description: Analo <br /> Differential Pressure 2 Inputs Analog Outputs Digitaf Inputs Digital Outputs Network Alarms Remarks <br /> Difference Across Fan Typical of Each <br /> Exhaust Air Damper 2 Exhaust Fan Sta�IStop � <br /> Exhaust Fan Proof 1 � Current Sensing � <br /> System Name: Qt ; Relay 4 <br /> y Speed, plus add'I info <br /> Exhaust Fan VSD 1 1 1 via gateway <br /> Plenum Level 2 . <br /> Description: Exhaust Airflow Monitoring � <br /> Analog �nit <br /> Inputs Analog Outputs Digital Inputs Digital Outputs Network Alarms R2ma1'kS <br /> Typical of Each Exhaust Air Temperature 1 <br /> High, Mid & Low Levei Exhaust Air Damper 1 <br /> Door Position 3 in Spray Booth, Mid — <br /> Level in Automation Filter Pressure Differentiai 2 2 <br /> Garage <br /> Door Lock Control 3 Located Mid Level <br /> High, Mid & Low Level System Name: Qty; <br /> in Spray Booth, Mid Control Room Air Handlin Unit <br /> Door Access Controf 2 Level in Automation g � <br /> � Garage Description: anaiog <br /> Inputs Analog Outputs Digital Inputs Digital Outputs Network Alarms Remarks <br /> Door Access Light 2 Located Mid Level Typical of Each <br /> Differential Pressure Supply Fan Start/Stop � <br /> Sensor 3 3 ,. <br /> Differential Pressure Located across final Supply Fan Proof � � Current Sensing T <br /> Switch � filters Relay <br /> Supply Fan VSD � � � Speed, plus add'I info <br /> via gateway <br /> System Name: Qty; Supply Airfiow Monitoring <br /> Unit � <br /> Automation Garage Make-up Air Handiing Unit � Supply Air Temperature 1 <br /> Description: anaiog Return Fan Start/Sto <br /> Inputs Analog Outputs Digital Inputs Digital Outputs Network Alarms Remarks P 1 <br /> Typical of Each � <br /> Su I Fan Start/Sto Return Fan Proof 1 � Relaent Sensing <br /> pP Y p 1 Y <br /> Supply Fan Proof � � Current Sensing Return Fan VSD 1 1 � Speed, plus add'i info <br /> Relay via gateway <br /> Speed, plus add'i info Return Air Temperature 1 <br /> Supply Fan VSD 1 1 � via gateway Return Air Enthalpy <br /> Supply Airflow Monitoring � Sensor � <br /> Unit Return Air Carbon Dioxide <br /> Supply Air Temperature 1 Sensor � ; <br /> Outside Air Temperature 1 <br /> Outside Air Temperature 1 . <br /> Freeze Stat 1 1 Hardwired Shutdown Outside Air Enthalpy � <br /> Sensor <br /> Heating Coil Control Valve 1 Freeze Stat 1 1 Hardwired Shutdown <br /> Filter Pressure Differential 1 � Cooling Coil Control Valve 1 <br /> Outside Air Damper � Heating Coil Controi Valve 1 <br /> Filter Pressure Differential 1 1 <br /> System Name: Qty; Smoke Detector 1 1 Hardwired Shutdown T <br /> Automation Garage General Exhaust Fan � Outside Air Damper 1 <br /> Description: Exhaust Air Damper 1 <br /> Analog Analog Outputs Digital Inputs Digital Outputs Neiwork Alarms Remarks <br /> Inputs <br /> Typical of Each Outside AirlMixed Air � <br /> Damper Hardwired Shutdown <br /> Exhaust Fan Sta�IStop � <br /> Exhaust Fan Proof � � Current Sensing <br /> Relay <br /> Speed, plus add'I info <br /> Exhaust Fan VSD 1 1 � via gateway <br /> Exhaust Airflow Monitoring � <br /> Unit <br /> Exhaust Air Temperature 1 . <br /> Exhaust Air Damper � <br /> Filter Pressure Differential 2 2 <br /> 900 SW 16th Street Suite 307 FSi consulting engineers <br /> Renton, Washington 98057 Solutions & Service � ' <br /> � <br /> � <br /> SYM REVISIUtd BY APPROVED DATE SYM REVISION BY APPROVED DATE ORAWN DATE SUBTITLE CURRENT REVISION SYMeOL DATE o � <br /> DA ACCEPTABILITY NJH 12122i15 CONTROLS POINTS LIST o <br /> 0 ISSUED FOR CONSTRUCTION FSi 12122115 � E'� y��� W2548317 Q 12/22/15 <br /> � THIS DESIGN AND/OR CHECKED cv <br /> W4�,��-'�ti `�'�. � SPECIFICATION ISAPPROVED RED 12122/15 SHEET u'> <br /> � BOE,��� a � Bsc NEER ��22��5 T�T�E BOEING 777X CWC BUILDING � <br /> APPROVED BY DEPT. DATE n A � I ■ /� � <br /> � CHECKED I V ' I <br /> �F°�Qti� ��� BUILDING40-58 � � <br /> � <br /> �,�: �STER `� APPROVED JOB NO. COMP NO. � <br /> Fss�otin+. E�'G Approver <br /> 40-Q58-M1i.1 ¢ <br /> APPROVED DWG NO. <br /> �z�2z��5 MECHANICAL MASTER EVERETT, WA 40-058-M1i.1 ' , <br />