My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12011 19TH AVE SE 2019-07-25
>
Address Records
>
19TH AVE SE
>
12011
>
12011 19TH AVE SE 2019-07-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2019 9:21:22 AM
Creation date
7/25/2019 9:21:10 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
12011
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NVL Laboratories, Inc. ' <br /> . <br /> 4708 Aurora Ave N,Seattle,WA 98103 INICLI <br /> p 206.5470100 I f 206.634.1936 I www.nvllabs_com LABS <br /> Asbestos And Other Fibers Analysis <br /> by Phase Contrast Microscopy <br /> Client:Alexander's Demo Abatement LLC Batch #: 1824435.00 <br /> Addres:704 145th St SW Method: NIOSH 7400 <br /> Lynnwood, WA 98087 Client Project#:49 <br /> Date Received: 12/11/2U1,8 <br /> Samples Received: 'F <br /> Attention:Mr.Wilmar Ramirez Samples Analyzed: 1 <br /> Project Location:12011 19th Ave SE Everett,WA 98208 <br /> N <br /> (Lab ID: 18125938 Client's Sample#: E#26 <br /> Date sampled:12/11/2018 <br /> Time Flow Rate Sample type:Clearance <br /> Start 01:10 PM 12.00 Location:Upstairs work area <br /> End 02:50 PM 12.00 Activity:Demo wallboard with texture <br /> Worker:Wilmar Ramirez <br /> Minutes 100 Ave.12.00 Comments: r Fibers/cc <br /> 1 <br /> LOQ fibers/cc Fibers/fids Fibers/mm2 RL f/cc <0.002 <br /> Liters Pump ID �7.0 0.002 <br /> � 1200 20 min 0.032 max 0.417 .5/100 <br /> Blank ave.(ftmm0)0,0 Micro.field area(mm2)0.00785 Effe.filtration area(mm2)385 __. <br /> .r- <br /> Sampled by: Client <br /> Analyzed by: Matthew McCallum Date Analyzed:12/11/2018 .;;- <br /> Reviewed by: Nick Ly Date issued:12/12/2018 Nick Ly,Technical Director <br /> *Samples are analyzed in accordance with the NIOSH 7400(Issue 2: 15 August 1994). If the samples were not collected by NVL Laboratories,then <br /> the accuracy of the results is limited by the methodology and acuity of the sample collector. The LOQ, Limits of Quantification, are the fiber <br /> concentrations, for the given volume of the sampled air, above and below which the results may be unreliable. The RL, Reporting'Limit defined in <br /> Method 7400 as LOD,is the fibers/cc below which the results may not be confidently distinguished from background levels. This report relates only to <br /> the items tested.It shall not be reproduced,except in full,without written approval of NVL Laboratories,Inc. . Unless otherwise indicated,the condition <br /> of all samples was acceptable at time of receipt.Intralaboratoy(Sr)Values will be provided upon request. <br /> r,..1no 1 n#4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.