Laserfiche WebLink
NVL Laboratories, Inc. IN` IL. <br /> U <br /> 170$A ,r ra Ave N Seanle WA 9R1C3 ��1 1 <br /> p 206';‘,,0100 I 7206 674.1331: I vnvivov tans L ABS <br /> Bulk Asbestos Fibers Analysis <br /> By Polarized Light Microscopy <br /> Client: NVL Field Services Division Batch #: 1808924.00 <br /> Address:4708 Aurora Ave. N. Client Project#:2018-0363 <br /> Seattle,WA 98103 Date Received: 5/10/2018 <br /> Samples Received:42 <br /> Attention: Mr.Jason Lindhal Samples Analyzed: 38 <br /> Project Location: 12011 19th Ave SE Everett, WA 98208 Method: EPA/600/R-93/116 <br /> & EPA/600/M4-82-020 <br /> Lab ID: 18046802 Client Sample#: 2018-0363-1-1 <br /> Location: 12011 19th Ave SE Everett,WA 98208 <br /> Layer 1 of 2 Description: White compacted powdery material with paint <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Calcareous binder, Calcareous particles, Paint Cellulose 2% None Detected ND <br /> Layer 2 of 2 Description: White chalky material with paper <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: 70 <br /> Gypsum/Binder Cellulose 26% None Detected ND <br /> Glass fibers 5% <br /> Lab ID: 18046803 Client Sample#: 2018-0363-1-2 <br /> Location: 12011 19th Ave SE Everett,WA 98208 <br /> Layer 1 of 2 Description: White compacted powdery material with paint <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Calcareous binder, Calcareous particles, Paint Cellulose 2% None Detected ND <br /> Layer 2 of 2 Description: White chalky material with paper <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Gypsum/Binder Cellulose 26% None Detected ND <br /> Glass fibers 6% <br /> Lab ID: 18046804 Client Sample#: 2018-0363-1-3 <br /> Location: 12011 19th Ave SE Everett,WA 98208 <br /> Layer 1 of 2 Description: White compacted powdery material with paint <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Calcareous binder, Calcareous particles, Paint Cellulose 2% None Detected ND <br /> Sampled by: Client <br /> Analyzed by:William Minor Date:05/14/2018 <br /> Reviewed by: Nick Ly Date:05/15/2018 Nick Ly,Technical Director <br /> Note: If samples are not homogeneous, then subsamples of the components were analyzed separately, All bulk samples are analyzed using both EPA <br /> 600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported%Asbestos(1%=0-3%,5%=1-9%, 10%=5-15%, <br /> 20%=10-30%,50%=40-60%),This report relates only to the items tested. If sample was not collected by NVL personnel,then the accuracy of the results is <br /> limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL <br /> Laboratories,Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government <br /> page 2 of 21 <br />