Laserfiche WebLink
NVL Laboratories, Inc. LI <br /> 4708 Aua <br /> io1rr Ave N.Ssttie'1JAF E03 NVI <br /> p2066070120 ([06.614:1935 v.tvw,nvE b'.mm L A B.... S <br /> Bulk Asbestos Fibers Analysis <br /> By Polarized Light Microscopy <br /> Client: NVL Field Services Division Batch#: 1808924.00 <br /> Address: 4708 Aurora Ave. N. Client Project#: 2018-0363 <br /> Seattle, WA 98103 Date Received: 5/10/2018 <br /> Samples Received:42 <br /> Attention: Mr.Jason Lindhal Samples Analyzed: 38 <br /> Project Location: 12011 19th Ave SE Everett,WA 98208 Method: EPA/600/R-93/116 <br /> &EPA/600/M4-82-020 <br /> Glass fibers 5% <br /> Lab ID: 18046807 Client Sample#: 2018-0363-1-6 Sample Status: Not Analyzed <br /> Lab ID: 18046808 Client Sample#: 2018-0363-1-7 Sample Status: Not Analyzed <br /> Lab ID: 18046809 Client Sample#: 2018-0363-2-1 <br /> Location: 12011 19th Ave SE Everett,WA 98208 <br /> Layer 1 of 3 Description: White woven fibrous material <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Calcareous binder, Calcareous particles Cellulose 98% None Detected ND <br /> Layer 2 of 3 Description: White woven fibrous material <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Calcareous binder, Calcareous particles Glass fibers 97% None Detected ND <br /> Layer 3 of 3 Description: White powdery material <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Calcareous binder, Calcareous particles, Fine particles Cellulose 2% Amosite 4% <br /> Glass debris <br /> Lab ID: 18046810 Client Sample#: 2018-0363-2-2 Sample Status: Not Analyzed <br /> Lab ID: 18046811 Client Sample#: 2018-0363-2-3 Sample Status: Not Analyzed <br /> Lab ID: 18046812 Client Sample#: 2018-0363-3-1 <br /> Location: 12011 19th Ave SE Everett, WA 98208 <br /> Sampled by: Client ,> . - <br /> Analyzed by: William Minor Date:05/14/2018 _,'' <br /> Reviewed by: Nick Ly Date:05/15/2018 Nick Ly, Technical Director <br /> Note: If samples are not homogeneous, then subsamples of the components were analyzed separately.All bulk samples are analyzed using both EPA <br /> 600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported%Asbestos(1%=0-3%,5%=1-9%, 10%=5-15%, <br /> 20%=10-30%,50%=40-60%).This report relates only to the items tested. If sample was not collected by NVL personnel,then the accuracy of the results is <br /> limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL <br /> Laboratories,Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government <br /> page 4 of 21 <br />