Laserfiche WebLink
NVL Laboratories, Inc. INIL <br /> 4705 Aurora Ave N,SrapJe V24 05168 <br /> p 206.04?0,00 I r 206 604 1636 i•rx.v,nvilans.com L A BS <br /> Bulk Asbestos Fibers Analysis <br /> By Polarized Light Microscopy <br /> Client: NVL Field Services Division Batch #: 1808924.00 <br /> Address: 4708 Aurora Ave. N. Client Project#:2018-0363 <br /> Seattle,WA 98103 Date Received: 5/10/2018 <br /> Samples Received:42 <br /> Attention: Mr.Jason Lindhal Samples Analyzed: 38 <br /> Project Location: 12011 19th Ave SE Everett,WA 98208 Method: EPA/600/R-93/116 <br /> &EPA/600/M4-82-020 <br /> Layer 3 of 4 Description: Gray vinyl <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Vinyl/Binder, Fine particles None Detected ND None Detected ND <br /> Layer 4 of 4 Description: Black soft asphaltic material on wood <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Asphalt/Binder, Fine particles, Wood flakes Cellulose 5% Chrysotile 3% <br /> Lab ID: 18046820 Client Sample#: 2018-0363-3-9 <br /> Location: 12011 19th Ave SE Everett,WA 98208 <br /> Layer 1 of 1 Description: Brown flat hard compressed fibrous material with surface <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Adhesive/Binder, Binder/Filler, Wood flakes Cellulose 97% None Detected ND <br /> Lab ID: 18046821 Client Sample#: 2018-0363-3-10 <br /> Location: 12011 19th Ave SE Everett,WA 98208 <br /> Layer 1 of 4 Description: Brown sheet vinyl <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Vinyl/Binder, Synthetic foam None Detected ND None Detected ND <br /> Layer 2 of 4 Description: Gray fibrous backing with white firm mastic <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Binder/Filler, Mastic/Binder Cellulose 39% None Detected ND <br /> Glass fibers 24% <br /> Layer 3 of 4 Description: Gray ceramic tile <br /> Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: % <br /> Ceramic/Binder None Detected ND None Detected ND <br /> Sampled by: Client <br /> Analyzed by: William Minor Date:05/14/2018 — <br /> Reviewed by: Nick Ly Date:05/15/2018 mm Nick Ly,Technical Director <br /> Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA <br /> 600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported%Asbestos(1%=0-3%, 5%=1-9%, 10%=5-15%, <br /> 20%=10-30%,50%=40-60%).This report relates only to the items tested. If sample was not collected by NVL personnel,then the accuracy of the results is <br /> limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL <br /> Laboratories,Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government <br /> page 8 of 21 <br />