Laserfiche WebLink
Cover Plate Finishesco Table H <br /> Standard Finishes Special Application Finishes <br /> White Polyester Off White Paint Black Paint Raw Brass <br /> Chrome Plated Bright Brass Finished Bronze Black Plated <br /> Satin Chrome Stainless Steel Custom Color <br /> Clad(3) Paint(2) <br /> Notes: <br /> 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. <br /> 2. Custom color paint is semi-gloss,unless specified otherwise. <br /> 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side.Cover plates <br /> are not listed or approved as corrosion resistant.Stainless steel clad cover plates are not available perforated. <br /> Installation Dimensions Table J <br /> Recommended Min.to Min.to Max. <br /> Cover Plate Cover Plate Max.Face Dropped Deflector <br /> Cover Hole Diameter Cover Plate <br /> Sprinkler Diameter Adjustment of Fitting to Distance below <br /> Model Plate inch in Ceiling inch Ceiling�'� Ceiling Temperature <br /> Model inch Rating <br /> (mm) (mm) (mm) inch inch <br /> (mm) (mm) <br /> RFC30 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F <br /> RFC43 RFC (84) (67) (13) (38 to 51) (13 to 25) (57°C) <br /> RFC49 <br /> 135°F(2) <br /> RFC58 RFC 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) <br /> (84) (67) (19) (38 to 57) (6 to 25) or 165°F3 <br /> (74°C) <br /> Notes: ■ <br /> 1. Face of fitting to ceiling dimensions are based on a nominal thread make up.Verify dimensions based on fitting and thread sealing method r <br /> to installation.A 1/2"x 1/2"brass nipple extension(Reliable P/N 6999991900)is available where necessary for replacement of existing sprinklers. <br /> 2. For use with 165°F(74°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F(38°C). <br /> 3. For use with 212°F(100°C)temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F(66°C). <br /> Installation <br /> Model RFC series sprinklers are intended to be installed in ac- Do not exceed the maximum recommended torque. Exceeding <br /> cordance with NFPA 13, NFPA 13R,or NFPA 13D,as well as the the maximum recommended torque may cause leakage or im- <br /> requirements of applicable authorities having jurisdiction. Mod- pairment of the sprinkler. Use care when inserting or removing <br /> el RFC series sprinklers must not be installed in ceilings with the wrench from the sprinkler to avoid damage to the sprinkler. <br /> positive pressure in the space above. Ensure that the 4 slots in <br /> the cup are open and unobstructed following installation.Model Install the cover plate by hand by pushing the cover plate into <br /> RFC series sprinklers are shipped with a protective cap that the cup and turning the cover in the clockwise direction until it <br /> should remain on the sprinkler until installed.The protective cap is tight against the ceiling. <br /> should be replaced following installation of the sprinkler and <br /> permanently removed only when the cover plate is installed and <br /> the sprinkler system is placed in service following construction. Application <br /> Model RFC series sprinklers are installed with the Model FC Model RFC series sprinklers are intended for installation where <br /> wrench.The use of any other wrench to installed Model RFC se- residential sprinklers are permitted or required by NFPA 13, <br /> ries sprinklers is not permitted and may damage the sprinkler. NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- <br /> Temporarily remove the protective cap during installation of the dent residential sprinklers. <br /> sprinkler. Insert the Model FC wrench over the sprinkler until the <br /> wrench engages the body. Do not wrench any other part of the Model RFC 30, RFC43, and RFC49 sprinklers are available in <br /> sprinkler/cup assembly. The Model FC wrench is designed to ordinary temperature classification for installation where the <br /> be turned with a standard 1/2" square drive. Tighten the sprin- Maximum Ceiling Temperature does not exceed 100°F(38°C). <br /> kler into the fitting after applying a PTFE based thread sealant Model RFC58 sprinklers are available in either ordinary o i <br /> to the sprinkler's threads. Recommended installation torque is 8 termediate temperature classification for installation wherill� <br /> to 18 ft/lb (11 to 24 N/m). Maximum Ceiling Temperature does not exceed 100°F (3 <br /> or 150°F(66°C), respectively. <br /> Bulletin 006 Rev.K !tenni) 0Page 6 of 7 <br /> February 2017 www.reliablesprinkler.com <br />