Laserfiche WebLink
. . � � <br /> Ltr. R. Wacker(2902 Ruckerj <br /> February 20, 2002 <br /> Page 2 <br /> �B. Two drinking fountains a�e required per Sections 2903.4 and 1105.4.1. (One at <br /> standard height and one at accessible height) Sce Section 1106.13 also. <br /> �. The equipment Floor, free weights room, and aerobics room shall each have <br /> "Mauimum Occupant L.oad Of 49 People" on a pennanent sign posled near the main <br /> entrance. This will keep the occupancy classifications at B and not trigger the <br /> requirement for a seismic evaluation nnd upgrade of the building. <br /> ✓10. The stainvay is required to have handrails per Section 1003.33.6. <br /> V11. Provide wall cross sections describing consttuction materials and methods of <br /> attachment and bracing. <br /> il,.��S ���12. Provide ceiling loc;ations and methods of construction. The sprinkler syste:n will <br /> � r,�,l�.l,��.� need to be revised to sprinkle any cavities between a ceiling and the structure above. <br /> �O�'�n f �3. Plaas must indicate the intent for ventilation in com�liance with the 2000 Washington <br /> State Ventilation and indoor air quality code. <br /> ,/l4. Plans must indicate the requirement for the lighting to comply with Chapter 15 of the <br /> 2000 Washington State Energy Code. <br /> �15. Plans must indicate the intent for all plumbing fixtures and surtounding facilities to <br /> comply with the 97 Uniform Plumbing Code. <br /> 16. The Uniform Mechanical Code limits the lengh of a dryer exhaust duct to !4 feet <br /> unless the manufacturers installation instructions allow moro. This could be an <br /> important consideration in Iceating the laundry room. See UMC SP1.3.2. <br /> Please prepare a response Ictter showing where each item in this co�rertion letter is addressed on the <br /> plun set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All rcquired submittals shall be of sufficient detail and contain sufficient information to ensurc that <br /> the proposed stivcture will be constnicted in compliance with all adopted codes. <br /> SincerelY, � (,� <br /> � �J� '��. <br /> � <br /> Steve Miller <br /> Associate Engineer <br /> s�i rn;oi,ri.rwrz�ioin.iot:io.n,:ae�co z/ <br /> I <br />