My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2722 COLBY AVE UMPQUA BANK 2019-08-07
>
Address Records
>
COLBY AVE
>
2722
>
UMPQUA BANK
>
2722 COLBY AVE UMPQUA BANK 2019-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2019 11:33:57 AM
Creation date
8/7/2019 11:33:48 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2722
Tenant Name
UMPQUA BANK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Date: February 28,2019 <br /> 1 Project Name: Umpqua Bank- Everett TI <br /> Lva Project No: 18065 <br /> Re: Permit Response Letter `AK:,,., <br /> FEB <br /> Memo C ® ? <br /> arya 470/9 <br /> To: James Bronder Pepfl/To: <br /> rr <br /> City of Everett, Public Works Department is/•`a�,R <br /> From: Erin Brouillette <br /> TVA Architects <br /> This letter is in response to the permit review letter#61901-004, sent on February 4,2019. <br /> 1. City of Everett Plan Review Comment: <br /> On Sheet A00o, the Type of Construction is indicated as///B, but the building's existing <br /> conditions exceed the number of stories for l//B construction per Table 504.4 at/31 stories <br /> for a non-sprinklered building. The number of stories for this structure appears to be 171 <br /> stories. Given the number of stories, the type of construction may be closer to satisfying a <br /> Type 11/A building, requiring 1-hr fire protection to the primary frame. Please indicate, if the <br /> new interior construction provides this protection, for instance at the columns at grids 3/E <br /> and 5/E as it does not appear to indicate this on Sheet A900. /BC504 and Table 601. <br /> Applicant's Response: <br /> Based on our evaluation of the existing conditions,we believe the building classification <br /> does not conform to Type IIIA. Non-sprinklered Type IIIA structures of type B occupancy <br /> are limited to 65 feet in height (Table 504.3) and have a story limitation of 5 (Table 504.4). <br /> The existing building is stepped with portions that are both 7 and 3 stories high. However, <br /> there is no building separation between these areas and therefore cannot be classified as <br /> two separate buildings.The building is therefore considered 7 stories high. <br /> The building is more typical of a Type IB due to the number of floors and the occupancy. <br /> However,the presence of existing building elements that are combustible (wood floors) <br /> would indicate that the building is non-compliant with current building code. <br /> Occupancy: B- Business(existing and proposed) Section 304.1 <br /> Fire sprinkler protection: Basement only <br /> Building Height:7 floors Table 504.3/504.4 <br /> Primary Structural Frame: Concrete Table 601 <br /> Floor Construction: Concrete (typical) &Wood (above proposed TI) Table 601 <br /> tva architects, inc. <br /> 920 sw sixth avenue suite 1500 portland,oregon 9924E <br /> phone:503 220 0668 www.tvaarchitects.com <br /> Robert Thompson,FAIA Tim Wybenga,LEED AP?Pamela Saftler,AIA,IIDA`Mandy Butter,AIA <br />
The URL can be used to link to this page
Your browser does not support the video tag.