My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3410 OAKES AVE B 2019-08-07
>
Address Records
>
OAKES AVE
>
3410
>
3410 OAKES AVE B 2019-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2019 4:03:14 PM
Creation date
8/7/2019 4:03:06 PM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
3410
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Upstate Engineering Project Title: MCNEILL <br /> PO Box 952 Engineer: amg Project ID: 0748 <br /> Lynnwood,WA 98046 Project Descr: 2-STORY SFR <br /> (206)280-4715 <br /> F.(206)834-6261 <br /> SERVICES@UPST8.COM Panted: 1 AUG 2017 6:35AM <br /> Wood Column File=C:\Users\Andy\DOCUME-11UPST8M-112017(0-110748J0-110748GR-1.EC6 <br /> ENERCALC,INC.1983-2017,Build:10.17.7.24,Ver:10.17.7.24 <br /> Lic.#:KW-06010196 Licensee: Upstate Engineering <br /> Description: Stud Check <br /> Code References <br /> Calculations per NDS 2015, IBC 2015, CBC 2016,ASCE 7-10 <br /> Load Combinations Used :ASCE 7-10 <br /> General Information <br /> Analysis Method: Allowable Stress Design Wood Section Name 2x6 <br /> End Fixities Top&Bottom Pinned Wood Grading/Manuf. Graded Lumber <br /> Overall Column Height 18.50 ft Wood Member Type Sawn <br /> slender calculations) Exact Width 1.50 in Allow Stress Modification Factors <br /> Wood Species Hem Fir Exact Depth <br /> Wood Grade Stud p 5.50 in Cf or Cv for Bending 1.0 <br /> Area 8.250 inA2 Cf or Cv for Compression 1.0 <br /> Fb+ 675 psi Fv 150 psi lx 20.797 inA4 Cf or Cv for Tension 1.0 <br /> Fb- 675 psi Ft 400 psi ly 1.547 inA4 Cm:Wet Use Factor 1.0 <br /> Fc-PrIl 800 psi Density 26.83 pcf Ct:Temperature Factor 1.0 <br /> Fc-Perp 405 psi Cfu:Flat Use Factor 1.0 <br /> E:Modulus of Elasticity... x-x Bending y-y Bending Axial Kf:Built-up columns 1.0 <br /> Basic 1200 1200 1200 ksi Use Cr:Repetitive? Yes <br /> Minimum 440 440 Brace condition for deflection(buckling)along columns: <br /> X-X(width)axis: Fully braced against buckling along X-X Axis <br /> Y-Y(depth)axis: Fully braced against buckling along Y-Y Axis <br /> Applied Loads Service loads entered.Load Factors will be applied for calculations. <br /> Column self weight included:28.437 lbs*Dead Load Factor <br /> AXIAL LOADS... <br /> ROOF LOAD:Axial Load at 18.50 ft,D=0.350,Lr=0.5833 k , <br /> BENDING LOADS... <br /> WIND LOAD:Lat.Uniform Load creating Mx-x,W=0.01644 klft <br /> DESIGN SUMMARY <br /> Bending&Shear Check Results <br /> PASS Max.Axial+Bending Stress Ratio = 0.5405:1 Maximum SERVICE Lateral Load Reactions.. <br /> Load Combination +D+0.60W+H Top along Y-Y 0.1521 k Bottom along Y-Y 0.1521 k <br /> Goveming NDS Forumla Comp+Mxx, NDS Eq.3.9-3 Top along X-X 0.0 k Bottom along X-X 0.0 k <br /> Location of max.above base 9.188 ft Maximum SERVICE Load Lateral Deflections... <br /> At maximum location values are... Along Y-Y 1.755 in at 9.312 ft above base <br /> Applied Axial 0.3784 k for load combination:W Only <br /> Applied Mx 0.4221 k-ft <br /> Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base <br /> Fc:Allowable 1,280.0 psi for load combination:n/a <br /> Other Factors used to calculate allowable stresses... <br /> PASS Maximum Shear Stress Ratio= 0.06914:1 Bending Compression Tension <br /> Load Combination +D+0.60W+H <br /> Location of max.above base 0.0 ft <br /> Applied Design Shear 16.593 psi <br /> Allowable Shear 240.0 psi <br /> Load Combination Results <br /> Maximum Axial+Bending Stress Ratios Maximum Shear Ratios <br /> Load Combination C D C p Stress Ratio Status Location Stress Ratio Status Location <br /> +D+H 0.900 1.000 0.06371 PASS 0.0 ft 0.0 PASS 18.50 ft <br /> +D+L+H 1.000 1.000 0.05734 PASS 0.0 ft 0.0 PASS 18.50 ft <br /> +D+Lr+H 1.250 1.000 0.1166 PASS 0.0 ft 0.0 PASS 18.50 ft <br /> +D+S+H 1.150 1.000 0.04986 PASS 0.0 ft 0.0 PASS 18.50 ft <br /> +D+0.750Lr+0.750L+H 1.250 1.000 0.09890 PASS 0.0 ft 0.0 PASS 18.50 ft <br /> +D+0.750L+0.750S+H 1.150 1.000 0.04986 PASS 0.0 ft 0.0 PASS 18.50 ft <br /> +D+0.60W+H 1.600 1.000 0.5405 PASS 9.188 ft 0.06914 PASS 0.0 ft <br /> +D+0.70E+H 1.600 1.000 0.03584 PASS 0.0 ft 0.0 PASS 18.50 ft <br /> +D+0.750Lr+0.750L+0.450W+H 1.600 1.000 0.4104 PASS 9.312 ft 0.05186 PASS 0.0 ft <br /> &t,:_ <br />
The URL can be used to link to this page
Your browser does not support the video tag.