INSULATEQ METAL OVHD � *
<br /> WALL PANELS — HIGH—PERFORMANCE INSULATED METAL INSULATEQ METAL WALL THRESHOLD WHERE OCCURS ,
<br /> � DOOR WALL PANEL PANEL
<br /> PREFINISHED SHT HOUSING � PREFINISHED SHT � 1/4" TO 1/2" TALL LIP AT EDGE OF SLAB. `
<br /> MTL GUl–fER OVER � MTL GUTTER OVER �
<br /> �� �� CHAMF�R EDGE AT 1 :1 .
<br /> WIDTH OF DOOR � ~�\ WIDTH OF DOQR � � PRE�INISHED SHT MTL , 1/2" COMPRESSIBLE FILLER STRiP '
<br /> OPENING, SLOPED TO ,,_��� � OPENING, SLQPED TO EDGE TRIM ' FILL ASPHALT PAVEMENT TO SLOPE AWAY
<br /> DRAIN 6" PAST JAMB, ���� ~��� ��, � /' � DRAIN 6" PA�T JAMB, ' � / FROM BUILDING TO MEE( EXISTING ,
<br /> SEAL ALL JOINTS � i � � � � SEAL ALL JOINTS , " PAVEMENT. SLOPE NOT TO EXCEED 1/4
<br /> � 1 » �-
<br /> \ �- i\� �� � I � � 2 1/2 `� � � ~� BACKER RaD & � PER 1 �_�„ fi
<br /> � , , _
<br /> �� �/ ' � ��`�_�' ,i STL CHANNEL � 57L CHANNEL SEp�qNr a SLOPE ,
<br /> a�
<br /> � , `
<br /> � � BACKER ROD �C , °4 a / ,
<br /> �
<br /> i SEALANT �
<br /> STL FRAMING �
<br /> P EFINISHED S T MTL � DOOR GUIQE INSULATED HM DOOR -- HM DOOR 7 1�2�� 6 7�8 �
<br /> R H
<br /> CLOSURE STRIP BTWN i JAMB EA. SIDE & FRAME, U-0.37� & FRAME
<br /> HOUSING & STL FRAME
<br /> SEALANT BOTH
<br /> SIDES OF SILL � INSUL�TED METAL �
<br /> O�HD DOOR HEAD EXTERIOR DOOR HEAD DETAI � B E�TERIOR D�OR JAN1B DET�IL � EXTERI � R DOOR SIL� DETA D FL.ASHING WALL PANEL _
<br /> SCALE: 1 1 2"=1 '-0" " ' " „ , " -
<br /> � A350 A5Q0 SCALE: 3 =1 -0 A350 A500 SCALE: 3" = 1 '-0" A350 A500 SCALE: 3 = 1 --0 A350 A5Q0 � � 16 GA MTL HAT
<br /> CHANNELS ,
<br /> SEALANT c�
<br /> � � SEALANT BOTH '��i .
<br /> PREFINISHED SHT INSUALTEQ ME7AL WALL PANEL � o SIDES 0� BASE
<br /> MTL END TRIM 2-�2 � � � --LOUVER FRAME FLASHING � ��� � PAI�JEL END
<br /> PANEL CLIP (12 GA GALV.) �, �, ' >� FLASHING
<br /> STL JAMB o C, PREFINISHED SHT \` �=
<br /> � FRAMING 5���� z � ,� BACKER ROD MTL FLASHING : . � , � = *
<br /> c� � � �ULL F'ERIMETER N `�
<br /> HEAD FASTENER Q � � � ���NY � OF OPENlNG �
<br /> ^ � � � °¢ — � < PREFINISNED MTL
<br /> HM DOOR AND FRAME PER RIVET � 12" O.C. � _� SILL FLASHING '
<br /> OVHD SCHEDULE , �'' � `�' 26 GA ANGLE TRIM �, � _ � ��� �
<br /> W DRIP EDGE
<br /> HIGH-PERFORMAf�CE �,,,.,�, N � � ))) ' �/ � BASE FLASHING �
<br /> DQOR HSS TUBE JAMB FRAMING / � CONT CLEAT � � � �/ W GLASS-FIBER �
<br /> FOR OVHD COILING DOOR 26GA FLASHING � �
<br /> SILL FLASHING � � � BATT INSULATION
<br /> � W/ DRIP EDGE � /
<br /> GUIDE ASSEMBLY � ¢ SEALANT /
<br /> WELDED TO GUIDE ASSEMBLY WELDE PANEL CLIP '� �` / _
<br /> FRAME STEEL TUBE 8c FASTENER
<br /> SLAB—ON--GRADE EDGE
<br /> O�IHD HIGH—PER�ORMANC ` IN5ULATION, CONT 2" RIGID �`.
<br /> DOOR � INSULATION @ 24"D MIN
<br /> GIRT LINE �
<br /> O�HD DOOR JAMB F OVHD DOOR SWI �JG DOOR JAMB � HORIZ PANEL JOI �IT DETAIL H LOU�ER SI �L DETAIL � BASE FLASHI �IG DETAl � K .
<br /> SCALE; 1 1/2"=1 '—Q" A350 A500 SCALE: 1 1/2"=1 '-0" A350 A500 SCALE: 3" = 1 '-0" SCALE: 3" = 1 '-0" SCALE: 3" = 1 '-0"
<br /> A200 �1500 1A10-14 A500 A200 A500
<br /> PREFINISHED SHT MTL RAKE A
<br /> 10" 1" LAP ROOFING MEMBRANE FLASHING W/ DRIP EDGE <
<br /> MEMBRANE OVER EDGE INTO GUTTER �;�YY �� ��f 1���'�,�f
<br /> � � FLASHING, HEAT GU7TER BRACKET WELDEQ TO MEMBRANE FLASHING, ����/���1��� ��� ���M�� ,
<br /> EALANT BOTH SIDES �NELDED CONT R00� EDGE STEEL HEAT WELDED
<br /> OF SILL FLASHING �
<br /> INSULATED METAL RO�FING ASSEMBLY, PREFINISHED SHT MTL COPING ROOFING ASSEM�LY,
<br /> CONT L 4 1/2" X 3 � WALL PANEL SEE ROOF PLAN SEE ROOF PLAN .
<br /> 1/2" X 1/4" LLH SHEET RFA160-10 CONT CLEAT, FASTENERS SHEET RFA1 fi0-10
<br /> � 12" OC �
<br /> Rn n
<br /> ANCHOR BOLT � � - 18 GA PREFINISHED SHT MTL � �
<br /> EALANT BOTH SIDES PANEL END
<br /> ` , GUTT�R. "HEAVY GUTTER'° � � �
<br /> OF BASE FLASHING ` FLASNING ` � CONSTRUCTlON & IN5TALLATION � '
<br /> �.,,, � PER SMACNA FIGURE 1 -168 � -
<br /> �� _ � � �� r� �
<br /> � � � % �' � � � ,
<br /> �
<br /> ,�� i i�
<br /> � � � �'
<br /> . PREFINISHED MTL B:F7-DE��C- X � � � ' � \ �
<br /> � 2„ SILL FLASHING W/ • � � o i
<br /> DRIP EDGE � °O
<br /> <l CONT CLEAT �_ J �� \ °
<br /> BASE FLASHING W f �, , �
<br /> � Gl1�SS-FIBER BATT FAS7ENERS (� 12" OC � � � ��i� , � 8.0. SOFFIT �
<br /> 1 i INSUlATION
<br /> _ � , I', ,
<br /> _ . .� EL. 73�_p�, E
<br /> a „ � � � WEATHER SEALS, BY DOOR INSULATED METAL WALL PANEL
<br /> / � : MANUF SOFFIT, U-Q.049, EXTENT '
<br /> � . STEPS AL4NG HANGAR DOOR
<br /> a � � : TRACK, COORDIN W/ MANUF '
<br /> � � � / ` ` ' 4'-2" VARIES, COORDIN W DOOR MANUF
<br /> �
<br /> SLAB-ON--GRADE EDGE .
<br /> INSULATION, CONT 2" RIGID � �
<br /> INSULATION @ 24"D MIN � INSULATED HANGAR DOOR &
<br /> BASE F�ASHING DETAIL � GIJTTER DETAIL M ROOF EDGE DETAIL � � CLOSURE PANELS, �—o.o�.� :�
<br /> .�,
<br /> SCALE: 3" = 1 '-0" SCALE: 3" = 1 '-0" SCALE: 3" = 1 '-0" �
<br /> A200 A500 RFA160, A200 A500 RFA16Q, A20� A5Q0 2�_4�� ��_���
<br /> HA� GAR DOOR SOFFIT P �
<br /> S�ALE: 1 1/2"=1 '-0" A200 A50O
<br /> �QR REF� ERE �I � E 0I� �Y .� �
<br /> BY DLRGROUP DATE 12.22.16
<br /> SYM REVISION BY ApPROVED DATE SYM REVISION BY APPROVED DATE DRawN DATE SUBTITLE CIJRRENT REVISION SYMBOL (� DATE
<br /> ACCEPTABILITY DLR GROUP 10.02.15 DETAIL�
<br /> 8086 TNIS DESIGN AND/OR CHEC ED O R ( V O�.ZH.� f
<br /> O R I G E D C S T A T I C T E S T F A C I L I T Y (I F C} W 3 0 9 9 7 1 5 D L R G R O U P J B 1 0.0 2.1 5 SPECIFICATION IS APPROVED R F i 0 7.2 8.1 6 SHEET
<br /> ARCHITECT EN INEER TITLE
<br /> - EDC STATIC TEST - RECOIiI� DRAWING W3099715 DLR GROUP RH 07.2�.16 � APPROVED BY DEPT. DATE EDC STATIC TEST FACILITY
<br /> CHECKED '•
<br /> ROBERT HOFFMAN ��L p��� ����� � JOB N0. COMP N0. "
<br /> STATE OF WASHINGTON APPROVED �;,
<br /> W3099715 .
<br /> a���ov�n ARCHITECTURAL MASTER EVERETI", WA ��� N�� 45-012-A500 ,
<br />
|