My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1520 41ST ST IVARS 2018-01-02 MF Import
>
Address Records
>
41ST ST
>
1520
>
IVARS
>
1520 41ST ST IVARS 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2019 8:47:14 AM
Creation date
8/9/2019 1:49:15 PM
Metadata
Fields
Template:
Address Document
Street Name
41ST ST
Street Number
1520
Tenant Name
IVARS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> PUBL/C f�YOlrKS �;enc vi�� �:-mail '. <br /> �.;r�r�i� � � ��I' � 1�1 �l <br /> March 14, 2013 <br /> Mr. Jason Chute <br /> Seatemp <br /> 20833 240`�' St <br /> Maple Valley, WA 98038 <br /> Project: Modifications and Replacement of Type I Nood <br /> Job Address: 1520 41stSt <br /> Plan Review: M1303-008 <br /> Dear Mr. Chute, <br /> In response to your recent application for a new suppression construction permit, the plans have <br /> been examined and you are advised that the permit review cannot be resumed until the <br /> following issues are resolved. <br /> Building <br /> 1. Please contact Teresa Firnstahl with the Planning Gepartment to discuss screeriiny <br /> requirements, if any, for the revis�d rooftop mechanical equipment submitted. Teresa <br /> can be reached by e-mail at tFirn�tahl��everettw�,4ov or by phone at 425-257-7281. <br /> Type I Hood <br /> 1. The Mechanical checklist is attached Co clarify the scope of what should be submitYed for <br /> permit. To assist our deparlment determine what is being proposed as new work on this <br /> perm�t, please revise the drawings as follows: <br /> a. In addition to notes clarifying the scope of new �Nork, please indicate new Type I <br /> houd work with dark lines. Existing work can be inuicated as light lines, and <br /> demolition work can be indicated with dashed lines. <br /> 2. A kitchen floor plan indicating the specific equipment served by the Type I and Type II <br /> hoods is required for plan review. � <br /> 3. The extent of the wall construction behind and adja�ent to the hood shou�d be shown on ' <br /> section drawings to indicate combustible or non-combustible construckion, including the <br /> required dimensioned clearances at kitchen equipment, per IMC 506.3.6. <br /> a. The extent of the stainless steel smooth, cleanable, nonabsorbent and <br /> noncombustihie material should be shown on the drawings and noted to extend 18 <br /> inches in all directions from the hood to the full height of the hood canopy, and <br /> below to the floor, per the exception to IMC section 507.9. <br /> 4. The listed ussembly for the grease duct enclosure system of one hour resistant grease <br /> duct fire wrap should be shown to meet the requirements of ASTM E 233E•, with the <br /> required clearances sl�own on the drawings, per IMC section 506.3.6, exception 3. <br /> b. Most tested assem,blies, incl�ding FyreWrap Elite, require two layers of Type I hood <br /> duct insulation, per ASTM E 2336. See attached. <br />
The URL can be used to link to this page
Your browser does not support the video tag.