�EGE�ID SYI� BO �S z
<br /> AB B R EUTATI 0 f� S G E �l E RA� �l OTES
<br /> SECTION LEffER �s CEILING MOUNTED OCCUPANCY SENSOR
<br /> OR DEfAIL NUMBER DESIGNATION SWITCH, OS INDICATES INTEGRAL OCCUPANCY SENSOR, D INDICATES & AND JT JOINT
<br /> �o°S � qT 1. OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE CITY OF EVERETT PRIOR TO COMMENCING CONSTRUCTION.
<br /> BUILDING, WALL SECTIONS INTEGRAL DIMMER
<br /> s AB ANCHOR BOLT K KIP(S)
<br /> �X � X � AND DETAIL REFERENCES O INTERCOM/SPEAKER KO KNOCK OUT 2. VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE BOEING PROJECT CONSTRUCTION MANAGER SHOULD CONDITIONS DIFFER FROM DESIGN DOCUMENTS.
<br /> �I 15A, 120V DUPLEX RECEPTACLE ACP 'ACOUSTICAL CEILING PANEL
<br /> ACT ACOUSTICAL CEILING TILE 3. THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CURRENT REVISION CLOUD S ON EACH SHEEf. IF THERE IS NO CLOUD ON A SHEEf THE ENTIRE
<br /> SHEET NUMBER WHERE DETAILED �I2p 20A, 120V, DUPLEX RECEPTACLE ADJ ADJACENT
<br /> �B LAGGBOLT SHEET IS IN THE SCOPE OF WORK. INFORMATION OR WORK (WHETHER CLOUDED OR N T) REFERRED TO FROM WITHIN A CLOUD IS INCLUDED IN THE SCOPE
<br /> SHEEf NUMBER REFERENCED FROM � 15A, 120V, FOURPLEX RECEPTACLE AFF ABOVE FINISHED FLOOR OF WORK (I.E: - A SECTION OR DEfAIL SYMBOL THAT LIES WITHIN A CLOUD ON A PLAN VIEW SHEEf IS INCLUDED IN THE SCOPE EVEN WHEN THE ACTUAL �
<br /> ,----� xx AGG AGGREGATE LEN LENGTH SECTION OR DEi�AIL DRAWN ON THE bEfAIL SHEEf IS NOT CLOUDED.)
<br /> ( 1 � FIRE ALARM HORN/STROBE, xx INDICATES CANDELA RATING AL ALUMINUM LF LINEAL FEET �
<br /> i i REFERENCE TO DETAIL/ENLARGED PLAN
<br /> �I DATA/TELEPHONE OUTLEf ALT ALTERNATE LL LIVE LOAD 4. KEEP ALL AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS CAUSED BY THIS SCOPE OF WORK. STORE CONSTRUCTION MATERIALS AND EQUIPMENT W AREA
<br /> #X # X # l\____ I � LWR LOWER DESIGNATED BY THE BOEING PROJECT CONSTRUCTION MANAGER.
<br /> FIRE SPRINKLER HEAD ALUM ALUMINUM
<br /> � ANCH ANCHOR, ANCHORAGE 5. VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND ENSURE THAT THE JOINING OF THE WORK OF VARIOUS TRADES MEEfS APPROPRIATELY.
<br /> ROOF/ACCESS HATCH MATL MATERIAL
<br /> DEfAIL DESIGNATION APA AMERICAN PLYWOOD ASSOC. BRING DISCREPANCIES ON THE DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON
<br /> X- MAX MAXIMUM
<br /> APPD APPROVED DISCOVERY. THE CONTRACTOR SHALL ADVISE BOEING, SUMMARIZE THE SITUATION AND PROVIDE RECOMMENDATIONS TO RESOLVING POTENTIAL CONFLICTS PRIOR
<br /> XXXX SHEEf NUMBER WHERE DETAILED p TOILET APPROX APPROXIMATE MB MACHINE BOLT TO SUBMIrfING ANY REQUESTS FOR INFORMATION (RFIs).
<br /> (IF SAME AS SHEET REFERENCED FROM) ASTM AMERICAN SOCIEfY OF MBR MEMBER
<br /> URINAL TESTING MATERIALS MTL METAL 6. CONFORM ALL WORK TO APPLICABLE CODES, REGULATIONS AND INDUSTRY STANDARDS. :
<br /> SECTION DEIAIL DESIGNATION � MFR MANUFACTURE(R)
<br /> X � MIN MINIMUM 7. COMPLY WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR CONSTRUCTION AREA AND SECURITY REGULATIONS.
<br /> BTWN BETWEEN
<br /> O LAVATORY MISC MISCELLANEOUS '
<br /> XXXXX XXXXX SHEEf NUMBER WHERE DEfAILED BLDG BUILDING 8. PROVIDE, AS IF DRAWN IN FULL, REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS.
<br /> BLKG BLOCKING MO MASONRY OPENING
<br /> BOT BOTTOM MT MOUNT(ED) (ING) 9. DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF MASONRY AND/OR CONCRETE WALLS, METAL STUDS, AND TO THE CENTERLINE OF COLUMNS,
<br /> UNLESS OTHERWISE NOTED.
<br /> SHEEf NUMBER REFERENCED FROM ° MOP SINK C CHANNEL MTL METAL ,
<br /> DF DRINKING FOUNTAIN CB CATCH BASIN N NORTH (COORDINATE) 10. DOOR OPENINGS ARE 6" FROM ADJACENT WALLS OR CENTERED W ROOM WALL, UNLESS DIMENSIONED OTHERWISE.
<br /> N NORTH ARROW CC CENTER TO CENTER NF NEAR FACE 11. PARTITIONS SHALL RUN FULL HEIGHT, FROM FLOOR TO FLOOR ABOVE UNLESS SHOWN OR NOTED OTHERWISE.
<br /> CEM CEMENT NIC NOT IN CONTRACT
<br /> 0 o SANITARY NAPKIN/TAMPON DISPENSER CF CUBIC FEET N0. NUMBER 12 PLANS WHICH APPEAR AS "BACKGROUNDS" ON CIVIL, STRUCTURAL, PLUMBING, HVAC, ELECTRICAL DRAWINGS ETC., ARE FOR THE PURPOSE ONLY OF
<br /> ELEVATION DATUM � � CJ CONTROL JOINT NOM NOMINAL ILLUSTRATING GENERAL PIAN. CONFIGURATION. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT PERTAINING TO THE
<br /> �� CL CENTER LINE NTS NOT TO SCALE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK.
<br /> OR SPOT ELEVATION CLG CEILING
<br /> � 13. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS IN DEfAIL FOR COORDINATION �
<br /> PAPER TOWEL DISPENSER/DISPOSAL CLR CLEAR(ANCE) OAC ONECENTER OF SPECIFIC TRADE REQUIREMENTS. COORDINATE ALL ROUGH-IN REQUIREMENTS FOR EQUIPMENT FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS
<br /> X'-X' CEILING HEIGHT A.F.F. COL COLUMN � °
<br /> PROJECT.
<br /> COMP COMPRESS(ED) (ION) OD OUTSIDE DIAMETER
<br /> DOUBLE ROLL TOILEf PAPER DISPENSER CONC CONGREfE OF OUTSIDE FACE 14. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT CONSTRUCTION MANAGER WHENEVER SUCH INSTRUCTIONS ARE REFERENCED
<br /> XXXXXX ROOM NAME e „ CONN CONNECTION OFCI OWNER FURNISHED CONTRACTOR IN THE CONSTRUCTION NOTES. �
<br /> HANDICAP GRAB BAR, 1 1/2 O.D. INSTALLED
<br /> XXXX ROOM NUMBER CONST CONSTRUCTION OPG OPENING 15. CONTRACTOR SHALL COORDINATE WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR STAGING AREAS WHERE CONTRACTOR MAY STORE SALVAGED
<br /> � CONT CONTINUOUS, CONTINUE OPP OPPOSITE, OPPOSITE HAND MATERIALS TO BE REUSED IN LATER PARTS OF THIS PROJECT AND WHERE MATERIALS TO BE STAGED BY BOEING ARE TO BE LOCATED.
<br /> TOILEf SEAT COVER DISPENSER
<br /> XX DOOR NUMBER CONTR CONTRACT(OR)
<br /> CT CERAMIC TILE PAR PARALLEL 16. SYMBOLS SHOWN ON MATERIALS LIST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING MATERIAL AND SEE CONSTRUCTION NOTES FOR MATERIAL
<br /> EARTH, DIRT, UNDISTURBED CTSK COUNTERSUNK PCC PRECAST CONCRETE CALLOUTS.
<br /> x PARTITION/WALL TYPE CY CUBIC YARD(S) PCF POUNDS PER CUBIC FOOT 17. WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED AS A RESULT OF DEMOLITION OR PERFORMANCE OF NEW WORK, THE CONTRACTOR IS TO PATCH AND
<br /> �� PERF PERFORATE(D) REPAIR THE EXISTING TO MATCH ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, .
<br /> EARTH, DIRT, COMPACTED �, DIA DIAMEfER PERIM PERIMEfER CEILING LINES, TOP OF BASE, CHANGE IN MATERIAL OR S(MILAR.
<br /> DBL DOUBLE PL PLATE °
<br /> X s� : 18. ALL RECESSES LOCATED WITHW FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN REQUIRED FIRE RATING OF THE PARTITION.
<br /> INTERIOR ELEVATION sTONE, GRAVEL, POROUS FILL DEMOL DEMOLISH, DEMOLITION PLAM PLASTIC LAMINATE
<br /> XXX XX X �WHERE SPACE (S LIMITED� DEP DEPRESSED PLYWD PLYWOOD 19. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE THE FINAL LOCATIONS OF MECHANICAL AND ELECTRICAL COMPONENTS. SEE THE REFLECTED CEILING ,
<br /> - DIA DIAMEfER PNL PANEL PIANS FOR LOCATIONS OF ITEMS IN THE CEILING; SEE DISCIPLINE SHEETS FOR ALL INFORMATION ABOUT THE MECHANICAL AND ELECTRICAL COMPONENTS
<br /> , BRICK, COMMON DIAG DIAGONAL PREST PRESTRESS(ED) INDICATED ON ARCHITECTURAL REFLECTED CEILING PLANS.
<br /> REVISION CLOUD WITH DIM DIMENSION PRF PREFORMED 20. PROVIDE CLOSURE, MEEfING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES; BETWEEN ALL FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS
<br /> REVISION LEfTER ��BEAK�� DL DEAD LOAD PSF POUNDS PER SQUARE FOOT AND ALL PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL, AND OTHER ITEMS.
<br /> CERAMIC TILE DN DOWN PSI POUNDS PER SQUARE INCH
<br /> ' A DS DOWNSPOUT PT POINT, PAINT 21. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR CUTTING AND PATCHING WORK WITHIN
<br /> �. .^� .�� .•� •�• � DWG DRAWING PVC POLYVINYL CHLORIDE THE BUILDING, BEYOND THE LIMITS OF THE ARCHITECTURAL DRAWINGS.
<br /> �•: • •. � �.- +.� �.� �. CONCRETE
<br /> E EAST (COORDINATE) R RADIUS (CURVATURE) 22 AT METAL STUD PARTITIONS, STUDS ARE TO EXTEND FROM FLOOR TO FLOOR U.N.O.. WHERE THEY CANNOT DO S0, DUE TO INTERFERENCE WITH NEW OR �
<br /> EXISTING DUCTS, PIPING, EfC., PROVIDE BRACING TO STRUCTURE ABOVE TO PROVIDE FOR EQUIVALENT SUPPORT OF PARTITION; SUBMIT EQUIVALENT SUPPORT
<br /> VCT CPT EA EACH R RISER METHOD TO ARCHITECT FOR REVIEW. ALL FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN THEIR RATING FROM FLOOR TO UNDERSIDE OF T
<br /> FLOOR MAT'L TRANSITION INsu�T�oN: BAn, LOOSE FILL, BLANKEf EB EXPANSION BOLT RB RESILIENT BASE STRUCTURE ABOVE, U.N.O.
<br /> EF EACH FACE REF REFERENCE, REFER TO
<br /> """� FLOOR RECESS INSULATION: RIGID EJ EXPANSION JOINT REINF REINFORCE(D) (ING) 23. PROVIDE ACCESS DOORS AS INDICATED OR AS NECESSARY AND VERIFY WITH MECHANICAL AND ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS �
<br /> EL ELEVATION REQ REQUIRE(D) (ING) REQUIRED BY THEIR WORK. ACCESS MUST BE PROVIDED FOR ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGES, CONCEALED JUNCTION
<br /> ELEV ELEVATION REV REVISION(S), REVISED BOXES, AND ELECTRICAL DEVICES OR ACCESSORIES. LOCATIONS AND SIZES OF EXPOSED ACCESS DOORS SHALL BE SUBMITTED TO THE ARCHITECT fOR REVIEW
<br /> n END WALL GUARD ALUMWUM EQ EQUAL RH RIGHT HAND
<br /> PRIOR TO INSTALLATION OF THE MECHANICAL AND ELECTRICAL EQUIPMENT.
<br /> EW EACH WAY RO ROUGH OPENING 24. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFEf`f IN THE AREA OF WORK IN ACCORDANCE WITH ALL SAFEf`( CODES, REGULATIONS AND BOEING
<br /> � , EXIST EXISTING S SOUTH COORDINATE REQUIREMENTS.
<br /> � CORNER GUARD BRASS, BRONZE, COPPER EXP EXPOSED � �
<br /> I I EXT EXTERIOR SECT SECTION 25. THE CONTRACTOR SHALL RETAIN A FIRE PROTECTION ENGINEER LICENSED IN THE STATE OF WASHINGTON T0 DEfERMINE/DESIGN THE MODIFIED FIRE
<br /> SF SQUARE FEEf SPRINKLER SYSTEM LAYOUT WITHIN THE AREA OF WORK. SAID ENGINEER SHALL STAMP, SEAL AND CERTIFY THAT HIS/HER DESIGN IS IN COMPLIANCE W/ALL �
<br /> METAL, STEEL, IRON SHT SHEET APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL COORDINATE A�L NECESSARY MODIFICATIONS AS A RESULT OF SAID ENGINEER'S DESIGN.
<br /> CPT-1 FINISH DESIGNATION FAs FASTEN(ER) •
<br /> FF FINISHED CEILING SIM SIMIIAR 26. PORTIONS OF THE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION: THE CONTRACTOR SNALL COORDINATE ALL WORK TO AVOID AS MUCH AS
<br /> GRID/GRID BUBBLE AND '�"���'�.`�:����`�.�'��-�:���.��'�: PLASTER: SAND, CEMENT, GROUT FF FACTORY FINISH SQ SQUARE POSSIBLE ANY INCONVENIENCE TO BUILDING OCCUPANTS AND PROVIDE FOR THEIR SAFEfY, ACCESS AND EGRESS THROUGHOUT THE PROJECT WORK. THE
<br /> X CENTERLINE FF fINISHED FL00R SST, SS STAINLESS STEEL CONTRACTOR SHALL FULLY SCREEN OFF AREAS UNDER CONSTRUCTION BY TEMPORARY SCREENS OR PARTITIONS AS NECESSARY TO LIMIT DUST, DIRT, NOISE, �
<br /> FGR FINISH GRADE ST STRUCTURAL TEE, STAIN FUMES OR OBJECTIONABLE ODORS FROM ENTERING OCCUPIED AREAS.
<br /> � '�`� ��� '���� � ��� PLASTER: GYPSUM WALL BOARD FH FIRE HYDRANT STD STANDARD
<br /> --- --- --- - CONSTRUCTION ABOVE OR ':-.`..
<br /> BELOW, BEYOND OR BEHIND (HIDDEN) FIN FINISH(ED) STL STEEL
<br /> FND FOUNDATION STR STRUCTURAL
<br /> „ � WOOD: FINISH SYM SYMMETRY,SYMMETRICAL
<br /> � CONSTRUCTION FLAG NOTE FOR SPECIFIC FOC FACE OF CONCREfE _
<br /> CONSTRUCTION DIRECTIVE FOF FACE OF FINISH SYS SYSTEM
<br /> WOOD: ROUGH CONTINUOUS FOIC FURNISHED BY OWNER/ T&B TOP AND BOTTOM �
<br /> GENERAL "BOAT" NOTE FOR INSTALLED BY CONTRACTOR
<br /> � SPECIFIC OR EXISTING HISTORICAL FO FINISHED OPENING T&G TONGUE AND GROOVE :
<br /> INFORMATION. WOOD: INTERRUPTED BLOCKWG FRO FOR REFERENCE ONLY TEMP TEMPORARY
<br /> FT FOOT THK THICK(NESS)
<br /> OA WINDOW TYPE FTG FOOTING TOC TOP OF CURB .
<br /> TOC TOP OF CONCREIE
<br /> PLYWOOD: SMALL SCALE FUT FUTURE TOL TOLERANCE
<br /> HANDRAILS, KICK PLATES AND OTHER FV FIELD VERIFY
<br /> XXX TOS TOP OF STEEL
<br /> PHYSICAL PROTECTION GA GAGE
<br /> FE� FIRE EXTINGUISHER CRFG GLASS FIBER REINFORCED GYPSUM TS STRUCTURAL TUBE
<br /> PLYWOOD: LARGE SCALE TYP TYPICA�
<br /> GALV GALVANIZED
<br /> FEC� FIRE EXTINGUISHER & CABINEf GC GENERAL CONTRACTOR UBC UNIFORM BUILDING CODE :
<br /> ��
<br /> aO O o UL UNDERWRITERS' LABEL
<br /> Q SUPPLY AIR DIFFUSER WALL TYPE: CONCRETE MASONRY (CMU) GI GALVANIZED IRON UNO UNLESS NOTED OTHERWISE
<br /> � RETURN AIR GRILLE _ GR GRADE UPR UPPER : °
<br /> GT GROUT
<br /> FLOURESCENT LIGHT FIXTURE � WALL TYPE: STEEL STUD GWB GYPSUM WALL BOARD VB VAPOR BARRIER
<br /> (PENDANT MOUNTED) VC VINYL COMP. TILE �
<br /> HDNR HARDENER VERT VERTICAL
<br /> FLOURESCENT LIGHT FIXTURE �-�� WALL TYPE: WOOD STUD HDWD HARDWOOD VIF VERIFY IN FIELD
<br /> (PENDANT MOUNTED) HDWR HARDWARE W WEST (COORDINATE)
<br /> � FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT
<br /> HG HIGH GRADE W WIDE FLANGE •• «'
<br /> HM HOLLOW METAL W WIDTH, WIDE
<br /> LIGHT (NL) CIRCUIT � WALL TYPE: EXISTING WC WOOD
<br /> � RECESSED OR PENDANT LIGHTING FIXTURE HORZ HORIZONTAL
<br /> � RECESSED OR PENDANT LIGHTING FIXTURE
<br /> HS HIGH STRENGTH WD WITH D G R O U P
<br /> W/ WITN p
<br /> � FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT -------- WALL TYPE: REMOVAL HT HEIGHT W/0 WITHOUT W2572915 - WBS Z.2.3.� .5 60o Stewart St. St@ �4OO '
<br /> L I G H T (N L) C I R C U I T IBC INTERNATIONAL BLDG. CODE W W F W E L D E D W I R E F A B R I C �
<br /> � WALL SCONCE 1 ID INSIDE DIAMETER I F C S U B M I T T A L seattle, Washington 98101
<br /> � WALL SCONCE 2 WALL TYPE: PARTITION (7'-0° HIGH) NOTE: REFER TO THE COLOR AND MATERIAL '
<br /> ID INSIDE DIMENSION SCHEDULE FOR ADDITIONAL FINISH AND
<br /> � EXIT SIGN (CEILING UNIT) IF INSIDE FACE o2.03.'�� Te) 206.267.�7�0
<br /> � fXIT SIGN (WALL MOUNT) WALL TYPE: GLASS IN INCH DESIGNATIONS/ABBREVIATIONS FaX ZO6.267.�7O�
<br /> INCL INCLUDED(D) (ING) SAZAN #500-1530
<br /> SYM REVISION . BY APPROVED DATE SYM REVISION BY APPROVED -0ATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE
<br /> AccEPTAB�u-n� o�R cRouP o4.,s.o� ABBREVIATIONS & SYMBOLS LEGEND w25�29�5 B o2.o3.� s
<br /> ORIG 40-056 IRC MANAGEMENT COMPLEX J 568271-01 DLR GROUP JJ 05,25.07 THIS DESIGN AND/OR cHECKE�
<br /> # SPECIFICATION IS APPROVED JJ 05.25.07 sHE�r
<br /> RECORD DRAWING CLEAN-UP J 568271-01 DLR GROUP JJ 12.31.07 � �NciN R Tir�E '.
<br /> � BOE,�� APPROVED BY DEPT. OATE IRC - WBS 2.2.3.1 .5 - CURING OVENS
<br /> A 40-056 IRC MANAGE ENT COMPLEX R SION J 5680 1— 0 G U JJ 6 08 cHECKE� G 2 �
<br /> M �� # 6 0 DLR RO P o .30. BUILDING 40 056
<br /> — RECORD DRAWING CLEAN—UP J# 568061-00 DLR GROUP JJ 12.12.08 : APPRovE� - �og No. �# 568271 -01 coMP No. .
<br /> B IRC — WBS 2.2.3.1.5 — CURING OVENS W2572915 SAZAN 02.o3.�s APPRovE° ARCHITECTURAL MASTER COL. N/A EVERETT, Wq °wc No. 40-056—G2
<br />
|