Laserfiche WebLink
M EC HAf� I CA � HUAC � EG E �l D <br /> GENERAL GENERAL GENERAL SUGGESTED ABBREVIATIONS SUGGESTED ABBREVIATIONS <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION <br /> 24/�2 � RECTANGULAR DUCT, FIRST NUMBER 1� RECTANGULAR DUCT, SQUARE ELBOW A ANCHOR KW KILOWATT <br /> INDICATES SIZE FOR SIDE SHOWN � �1 WITH TURNING VANES ❑R THERMOSTAT, REMOTE, CEILING <br /> 24 �2 AAV AUTOMATIC AIR VENT KVA KILOVOLT-AMPERE � <br /> AD ACCESS DOOR LAT LEAVING AIR TEMPERATURE (°F) <br /> 24/�2 DUCT SHOWN IN SECTION, ARROW ADD ANGULAR DOWN DISCHARGE LBS, # POUNDS <br /> � POINTS TO SIDE CALLED OUT FIRST 1 RECTANGULAR DUCT, RADIUS VANED ELBOW � HUMIDISTAT, WALL AF AIR FOIL WHEEL LWT LEAVING WATER TEMPERATURE (°F) <br /> , AFF ABOVE FINISHED FLOOR <br /> AP ACCESS PANEL MA MIXED AIR <br /> 24� ROUND DUCT, NUMBER INDICATES APPROX APPROXIMATELY MAX MAXIMUM � <br /> �� � EXTRACTION GRID Q HUMIDISTAT CEILING ARCH ARCHITECTURAL MBH HEAT CAPACITY BTU PER HOUR X 1000 ' <br /> � 24� � DIAMETER � AUD ANGULAR UP DISCHARGE MCC MOTOR CONTROL CENTER <br /> � 24��2� OVAL DUCT, FIRST NUMBER INDICATES AVG AVERAGE MECH MECHANICAL <br /> MAJOR DIAMETER SECOND NUMBER �'�-�� FLEXIBLE DUCT Qp DUCT TYPE SMOKE DETECTOR BI BACKWARD INCLINED WHEEL MIN MINIMUM <br /> 24 �2� INDICATES MINOR DIAMETER BDD BACK DRAFT DAMPER MOV MOTOR OPERATED VALVE � <br /> BFP BACKFLOW PREVENTER MTD, MTG MOUNTED, MOUNTING <br /> SUPPLY AIR DUCT, SQUARE OR �� � BHD BOTTOM HORIZONTAL DISCHARGE NC NORMALLY CLOSED <br /> RECTANGULAR ELBOW FACING TOWARDS FLEXIBLE DUCT CONNECTION 4 p DUCT TYPE HEAT DETECTOR BHP BRAKE HORSE POWER NIC NOT IN CONTRACT <br /> BLDG BUILDING NO NORMALLY OPEN / NUMBER <br /> BOD BOTTOM OF DUCT <br /> SIDEWALL SUPPLY AIR DIFFUSER, NTS NOT TO SCALE <br /> i � x � SUPPLY AIR DUCT, SQUARE OR x � GRILLE OR REGISTER AND CFM � STATIC PRESSURE REGULATOR BOP BOTTOM OF PIPE NPSH NET POSITIVE SUCTION HEAD <br /> � � RECTANGULAR ELBOW FACING AWAY 100 CFM BOS BOTTOM OF STEEL . <br /> AIR FLOW BTU BRITISH THERMAL UNIT OA OUTSIDE AIR <br /> BTUH BRITISH THERMAL UNIT PER HOUR OBD OPPOSED BLADE DAMPER <br /> EXHAUST, RETURN OR SUPPLY AIR DUCT �� SIDEWALL RETURN/EXHAUST AIR GRILLE T H TEMPERATURE SENSOR, HUMIDITY BW BUTTWELD OF OVERFLOW <br /> ROUND, ELBOW FACING TOWARDS 100 CFM OR REGISTER AND AIR FLOW SENSOR, DUCT MOUNTED OS&Y OUTSIDE SCREW AND YOKE A <br /> C COMMON OD OUTSIDE DIAMETER <br /> 1 EXHAUST, RETURN OR SUPPLY AIR DUCT i�,� Cv FLOW COEFFICIENT <br /> � °C TEMPERATURE - DEGREES CELSIUS � <br /> � ROUND, ELBOW FACING AWAY ; �oo cFM SCREENED OPENING AND CFM AIR FLOW � THERMOSTAT, WALL CAP CAPACITY (O.F.C.I.) OWNER FURNISHED CONTRACTOR INSTALLED ) <br /> ` CC COOLING COIL PBD PARALLEL BLADE DAMPER <br /> EXHAUST AIR OR RETURN AIR DUCT, -- SUPPLY OUTLET, CEILING TYPE, DIFFUSER CCW COUNTER CLOCKWISE ROTATION PD/oP PRESSURE DROP OR DIFFERENTIAL PRESSURE <br /> � �� � -- OR GRILLE, SQUARE OR RECTANGULAR AND � NIGHT THERMOSTAT CFM CUBIC FEET PER MINUTE PDI PLBG. & DRAINAGE INSTITUTE <br /> SQUARE OR RECTANGULAR, ELBOW � `J � � <br /> FACING TOWARDS _- CFM AIR FLOW (SEE NOTE 3) N CI CAST IRON POC POINT OF CONNECTION <br /> CENTER LINE POS POSITION <br /> EXHAUST AIR OR RETURN AIR DUCT, � COND CONDENSATE PRESS PRESSURE <br /> I ��� SQUARE OR RECTANGULAR, ELBOW � � � � SUPPLY OUTLET, CEILING TYPE, ROUND T THERMOSTAT, CEILING CONN CONNECTION <br /> FACING AWAY AND CFM AIR FLOW (SEE NOTE 3) � CONT CONTINUED/CONTINUATION PS PRESSURERSW TCH ING VALVE <br /> CPLG COUPLING PSIG PRESSURE - POUNDS PER SQUARE INCH, GAUGE <br /> �—�� TRANSITION RECTANGULAR TO LINEAR DIFFUSER AND CFM AIR FLOW � TEMPERATURE TRANSMITTER CPVC CHLORINATED POLYVINYL CHLORIDE PSV PRESSURE RELIEF (SAFETY) VALVE <br /> RECTANGULAR � (SEE NOTE 3) � CW CLOCKWISE ROTATION PVC POLYVINYL CHLORIDE <br /> DA DIRECT ACTING RA REVERSE ACTING (CONTROLLER) / RETURN AIR <br /> DB DRY BULB TEMPERATURE <br /> � TRANSITION AT TAKE OFF ���I �� RETURN/EXHAUST REGISTER OR GRILLE, DBD DOWN BLAST DISCHARGE RECT RECTANGULAR <br /> � I�J CEILING DUCT TYPE AND CFM AIR FLOW DIA � DIAMETER REF REFERENCE <br /> - REV REVISED <br /> DIS DEIONIZED WATER SUPPLY RH RELATIVE HUMIDITY <br /> TRANSITION SQUARE OR RECTANGULAR RETURN/RELIEF GRILLE, CEILING TYPE, DIR DEIONIZED WATER RETURN RM ROOM <br /> TO ROUND OR OVAL ��- NON-DUCTED DN DOWN ROT ROTATION <br /> � DS DOWNSPOUT RPM REVOLUTIONS PER MINUTE <br /> uP � DWG DRAWING RQD REQUIRED <br /> �- DUCT OFFSET UP OR DOWN � UNIT HEATER, HORIZONTAL VAV BOX LEG EN D dB DECIBELS RTN RETURN <br /> DOWN � EA EXHAUST AIR / EACH RV ROOF VENT <br /> R ,� EAT ENTER AIR TEMPERATURE ('F) SA SUPPLY AIR <br /> � EFF EFFICIENCY SCFH STANDARD CUBIC FEET HR <br /> � OPPOSED BLADE DAMPER UNIT HEATER, VERTICAL PROJECTION ELL ELBOW SCFM STANDARD CUBIC FEET%MIN <br /> � � ELEC ELECTRICAL SHC SENSIBLE HEAT CAPACITY <br /> 1ST CHARACTER: 2ND CHARACTER: ELEV, EL ELEVATION SHF SENSIBLE HEAT FACTOR <br /> � PARALLEL BLADE DAMPER LINED DUCT V= VARIABLE AIR VOLUME ' F= FAN POWERED UNIT ESP EXTERNAL STATIC PRESSURE SHT SHEET <br /> � ---- TERMINAL UNIT C= SHUTOFF UNIT EVAP EVAPORATOR SO SCREENED OPENING <br /> EWT ENTERING WATER TEMPERATURE SOV SOLENOID OPERATED VALVE <br /> �—�— VOLUME DAMPER =_ 3RD CHARACTER: EXH EXHAUST SP STATIC PRESSURE <br /> SOUND ATTENUATOR XXX � E ELECTRIC HEAT EXIST EXISTING SQ SQUARE <br /> -- � X I� W= HOT WATER HEAT EXT EXTERIOR / EXTERNAL SS STAINLESS STEEL <br /> C= NO HEAT COIL 'F TEMPERATURE - DEGREES FAHRENHEIT STL STEEL <br /> �r � <br /> DUCT DAMPER, MOTOR OPERATED � LINED DUCT WITH ACCESS DOOR FC FORWARD CURVE WHEEL STRUC STRUCTURAL <br /> � l DM � � (ELECTRIC OR PNEUMATIC) AD SD AND SMOKE DAMPER MARK NUMBER FD FIRE DAMPER SW SOCKET WELD <br /> FLR FLOOR SUCT SUCTION <br /> FCO FLOOR CLEAN OUT TDH TOTAL DYNAMIC HEAD <br /> ` - BACK DRAFT DAMPER (ALLOWS �_ LINED DUCT WITH AXIAL FLOW FAN FOB FLAT ON BOTTOM (FEET OF WATER) <br /> BDD FLOW IN DIRECTION OF ARROW) FOF FACE OF FLANGE <br /> TEMP TEMPERATURE <br /> FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR TH TOTAL HEAD (FEET OF WATER) <br /> AD OR AP THC TOTAL HEAT CAPICITY <br /> ACCESS DOOR (AD) OR FOT FLAT ON TOP <br /> � FPM FEET PER MINUTE THD TOP HORIZONTAL DISCHARGE <br /> 0 � ACCESS PANEL (AP) CENTRIFUGAL FAN THRD THREADED <br /> FRP GLASS FIBER REINFORCED PLASTIC TOD TOP OF DUCT <br /> T FS FLOW SWITCH <br /> TOS TOP OF STEEL <br /> �.� � FIRE DAMPER (1 HOUR) � CENTRIFUGAL FAN, INLET GUIDE VANES V FACE VELOCITY FPM TOP TOP OF PIPE <br /> � <br /> � F�. D � TP TOTAL PRESSURE <br /> F� GAL GALLONS TS TEMPERATURE SWITCH <br /> ,-, n GPM GALLONS PER MINUTE TSP TOTAL STATIC PRESSURE <br /> � FIRE DAMPER (2 HOUR) I �-�{ EXHAUST FAN GALV GALVANIZED N TURNING VANE <br /> � <br /> 1�,^�FD� '—' � GA GAGE, GAUGE TYP TYPICAL <br /> � SUPPLY AIR FLOW DIRECTION HC HEATING COIL UBD UP BLAST DISCHARGE <br /> HD HEAD - FEET OF WATER <br /> HORIZ HORIZONTAL VAV VARIABLE AIR VOLUME <br /> HP HORSEPOWER VD VOLUME DAMPER <br /> RETURN, OUTSIDE OR EXHAUST AIR HPC HIGH PRESSURE CONDENSATE VP VELOCITY PRESSURE <br /> �� FLOW DIRECTION HR HOUR VERT VERTICAL <br /> HVAC HEATING, VENTILATING AND AIR CONDITIONING �A VENT TO ATMOSPHERE <br /> HPU HEAT PUMP UNIT VTR VENT THROUGH ROOF � A <br /> HTG HEATING Wg WET BULB TEMPERATURE <br /> ID INSIDE DIAMETER WCO WALL CLEAN OUT <br /> IE INVERT ELEVATION WG WATER GAUGE (INCHES OF WATER) OFFMAN <br /> IGV INLET GUIDE VANE WHA WATER HAMMER ARRESTOR W5741115 <br /> INSUL INSULATION W/ WITH PHASE 1 RENOVATION PACKAGE � N G I N E E R S <br /> I N I NC H ES 1101 2nd,Suite 400�Seattle,wA ss�o� <br /> IFC SUBMITTAL ph206.623.0717�fax206.624.3775 <br /> 07.02.18 ( coffman.com <br /> LASTI NG creativiry�rasults�relauonships <br /> a <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE N N SYMBOL DATE <br /> y�! J������ ACCEPTABILITY COFFMAN 05.25.18 HVAC LEGEND W5741115 A 07.02.18 <br /> A WORKPLACE ENVIRONMENT INVESTMENT W5741115 CEI PJ 07.02.18 ��''oF w��►'�`� THIS DESIGN AND/OR CHECKED <br /> Q���`�' '�'��b■ SPECIFICATION IS APPROVED P. JONES 05.25.18 SHEET <br /> ���,��� `Z��� � � TITLE WORKPLACE ENVIRONMENT INVESTMENT <br /> i v, APPROVED BY DEPT. DATE COFFMAN 05.25.18 M 1 A M 1 <br /> CHECKED <br /> �� � BUILDING 40 SITE <br /> � JOB N0. COMP N0. <br /> � � z'�� � j� ,aPPRovE� — W5741115 <br /> �o R��r s��'° <br /> �SSIONAL ���� APPROVED DWG N0. <br /> MECHANICAL MASTER EVERETT, WA 40-SITE-M 1 A <br /> RI�Rl1 R <br />