Laserfiche WebLink
�; <br /> C D <br /> I � <br /> 2 1 /2"VAC �- 3/4"AIR GENERA � N� TES_ <br /> �, 1 1 /4" 3"VAC >> <br /> � I , REFER TO SHEETS MI & Mla <br /> �, 2"IW 3/4"AIR 1 1 4 PWR �W� FOR SYMBOLS AND ABBREV I AT I ONS , . . <br /> � „ <br /> �� 1 1/4 AI MATCHLINE - SEE SHEET OM112 '4 <br /> � - __ _ _ :� � <br /> 4" 4" 2 , REFER TO SHEET Mln FOR PLUMBING � � <br /> - 3" � � � �� �° 2 1 2" �''' S 013 � SCHEDULES , <br /> 6 c� „ � <br /> � �� 3 � I / � � Q 1 1 / � <br /> _ � _ � _ � _� _ I _ _ _� P_13 __ _ �____ _ > _ _ 3 , ALL VACUUM, L I NES TO BE ' <br /> ' - �\ > Q � 2 � ,� - <br /> SLOPED I /8 PER FOOT (MIN . ) <br /> � „ 1 /2" � / TO VACUUM UNIT , <br /> 2 1 2 3 fi <br /> Q � � q � " -�- 2 � �2 2 � �2 � 4 , ALL AIR OUTLETS TO BE I /2 " <br /> I � 3/4" � Q � I II � DYNAQUIP DC-2I2SL QUICK DISCONNECT , <br /> 3 � � � � 3,> 3 � �_� � �,0� - �-- I VAC- + �, I 1 � �� UNLESS NOTED OTHERWI SE , _ <br /> 2' 2 , � 3 I 023 � �_- g� <br /> ( OM115IM5�48 SP- 1 2 � � � _ � � � � � z I � _ 5 . ALL VACUUM OUTLETS TO BE <br /> �� � � 3�4�� � �� 1 /2" � c¢n ��--2 I /2 " C 2 I /2 UNLESS NOTED OTHERWI SE , , <br /> , � �� i � � � 6 , NOT USED <br /> SP-1 2 1 /2" 2 1 /2 1 - - �.,� , SSW � , <br /> ,� <br /> „ �, <br /> I >> I „ � I > » I Q <br /> 2 1 /2" 2 1 /2 � „ 1 /2 ' � 1\ 1 2„ I -6 I- � � > » <br /> �--- S� � , 020 1 1 /4" SSW F AIR / 8 " RWL FOR CONT , IE 95 -3 7 , ALL ( NON RESPIRATOR ) BRANCH AIR LINES <br /> _-_.._� 2 � �2�- � „ COf�TI.UP TO P-- � , ,; UP SEE SHT . I M I I 5 SERV I NG QU I CK D I SCONNECTS SHALL HAVE <br /> _ _ _ _ _ - __ r 3 4a-=L = _ ISEE �HT. 1 M1 1 _ _ _ _ � I -6 _ _ A HANSEN EXCESS FLOW AUTOMAT I C SHUT- # <br /> „ 3 4" ° -� `-'�--_-�� � „ , � � � OFF VALVE DOWN STREAM OF BALL VALVE , <br /> I 1 I 1 1 4'�" ' 11 11 q�"'�—;�->-____- � 2 I /2 6 � CO I I <br /> / 1 1 //' � �� � ��� � � 1 " 2�� 2 1 2' I I /2 " P W E O R „ 8. F O R S U P P O R T S T E E L S E E D W G 1 S 1 1 5 <br /> I t 6 I � � � CONT UP TO P- 13 2 � /2 <br /> „ PW ±- � - - �` . <br /> 6 PV�-�� � A '- A A � A _ 1 e � �� 2 �� SEE SH l� . I ' I I 5 9 , RUN A I R AND WATER RUN , „ <br /> 3 AIR 3/4„ _ � �� �� 1 1 / i - - - I � PW �� _ � � BETWEEN 95 -0 AND 96 -0 ELEVAT I ON , <br /> CO � - \i <br /> - � >> <br /> 2>>SS ,>���vv i „ � � g , � � <br /> „ 2 1 /2 2����' „ 3�4„ 3 4 " 2 022 � � �4 <br /> _ _ � � „ 4„ � -� � �2� / _ � � <br /> I ' PWR „ '� ��J` _S P E C I F I C N O T E S_ <br /> 3/4" 2 � 2 �� � � 2 1 /2" � 4 �� 3 , ;� 3 4" AIR DROP TO HEAT WHEEL UNIT. �~ <br /> „ � � �+-� /` � 5 - FOR CONT. SEE SHT. C-83 � � „ <br /> � 1 1 /4 S SW FO � I � � I � _ I I � - - ; - <br /> CONT. UP TO P- � c�n 3 >> � P- I 3A CO � RW� - ' A�D ON� AT AHANDT RAILAOF CATWALK. <br /> I SEE SHT. 1 M1 1 „ 2 1 /2 � �� � - 1 � 8 >> <br /> _ _ _ _ _ _ _ _ _ _ 4 _ _ �AIR _ _ �� � - _ - -- 12"DIA SLEEVE 2 NOT USED <br /> � � � I.E. 543. 16 � <br /> „ �.� � <br /> - - - �--- - - - _ 1 1 /4 S SW I � 5 � I I " <br /> -�L-�D-F9I�----�- CA P � <br /> � 019 I P- 13 FUTURE P-� � 1 1 /2" , � P <br /> SUMP � 0 3 3/4" PW DROP TO 44" <br /> _ _ _ _ _ _ _ _ � _ � -� � �2�� 3 4�� 4 �� 1 D I �A , F , F . MOUNT ON THE COLUMN <br /> _�.� 4 I / � j a� FOR P- I 3A ( HOS E STAT I ON ) . �� <br /> , !..., N <br /> ���� SP-43 UTURE � � � �" - �� � � 024 ' I I 4�VACUUM UN I T D I SCHARGE OUTLET �= <br /> I � 2 1 2'°SP-44 g � „ AMMON I A BXHAUSTNDUCTTAND ;H.� <br /> VALVE „ I 3 <br /> IN VERTICAL t 1 1 4 � SAN -�'j�----+� OMN2EFORDEXACTEROU� I NGEAND <br /> I POSITION I I , <br /> I I � � CONNECTION , <br /> - - - - - - - -- A���- - � - � - - _ - � - - - - I 2 5�4 " I WG FOR CONT , UP TO 4 " FD3 _ <br /> � 3r4 � T SEE SHT , I M I I 5 , <br /> _ C 0 , i- � I I �--- <br /> - 9 Q w� � - <br /> � �, 1E I <br /> � � � � o � � �� ____� 6� PUMPS SP-43 & SP-44 ARE FUTURE , � <br /> �, TERMINATE PIPING AT 2 I /2 VALVE . <br /> z � I I � I � � I ��� I � � „ � „ , <br /> 7� 1 /2 AIR DROP ON OUTSIDE OF MECH. ROOM <br /> - �--� „ , „ � � „ „ „ „ � �'. <br /> -� w 3/4 I 2 1 �/2 4 � WITH PIPE THRU WALL 48 A.F.F. TO A 1 /2 x1 /4 <br /> _ �' ' � SAN � � P CEJN �10-310- 1455 QUICK DISCONNECT. <br /> U I <br /> Q w � B � 3/4�' E----0 1 � 8� 4" FD3 AT LOW POINT OF RETURN AIR PLENUM. <br /> �10 � SEE STRUCTURAL DWG. SHEET S285 FOR LOCATIONS = <br /> � I � I I I I I � � IN VERTICAL PAINT BOOTHS AND SHEET S287 <br /> 1 1 /� ' ' /2" AIR FOR LOCATIONS IN THE DOLLY PAINT BOOTH. <br /> , --� 1 1 /4" SSW FOR �� ^ �� I �O » 4„ 9� FUTURE 3/4" AIR DROP TO HEAT WHEEL. <br /> � CONT.UP TO P-8 � '� I � � � � 10 FIVE GALLON BLADDER EXPANSION TANK � <br /> - -- - - - - -- - E E S H T. 1 M 1 1 5--- � ���J - - � - - ---� ' � - - - - - - � <br /> � � � • T-IE F I RST FLOOR SHALL NOT BE 1 1 1 1 /2" AIR LINE UP INCREASING TO 2" AIR LINE <br /> 021 „87'�_8�� --- 6" I �j 4" SAN WASTE FO C�RE DR I LLED AT ANY LOCAT I ON <br /> „ SLOPE 1 4 „ 5 �i� FROM BASEMENT TO FIRST FLOOR. <br /> 4" 4 � 4" PER FOOT 4 88 „ z � 4" 1 MN15 UP SEE SH�f. A L FLOOR PENETRAT I ONS SHALL <br /> —� CO 3 4 SLOPE 1 4 Q � P � H,VE SLEEVES SET PR I OR TO F I RST <br /> „ i IWG „ I � OR SLAB POUR , R A B C D , <br /> 6 6 1 � PER FOOT ��' CO � � � B <br /> SP- 1 � � � � I <br /> SP-4 --IWG �I <br /> , „ ( <br /> SUMP SU�+ 6" 2 1 / 4 -I � 4 <br /> SP-4 31 SP- 1 23 �� 4" : � : •; P oM � � o oM � � t OM I I 2 <br /> 1 1 �4„ P - PWR - �- 1 1 2"� 1 A - - - �3 - <br /> „ „ _ _ , „ <br /> 4„ 2 1 /2 � 4" � 2 1 1 /�" - � � ,'S OM I I 3 I OM I I 4 M � ► 12 <br /> `C� - IW -_ IW I CO 2 � I„ 4„ - 6" � <br /> >> <br /> , � , „ � 8 �i _ FOR CONT SEE SHT. C-83 I OM I I 6 oM � 1 � OM I I 8 <br /> MATCH LINE � - RWL � � <br /> � _ _ i � - - � �-� - - - <br /> SEE SHEET OM I I 8 1 1 /4"PW 1 1 /2"HWC +'' i I , � oM � � g OM I 20 oM � 2 i <br /> � 3,_�„ <br /> � 10 <br /> 8" RWL FOR CONT. UP CW , HW & HWC UP 12"DIA SLEEVE <br /> SEE SHT. 1 M1 15 FOR CONT SEE SHT I.E. 543.16 KEY PLAN <br /> IMI 15 N �� <br /> �������� N.T.S. <br /> SECTION LETTER �« <br /> / OR \ <br /> DETAIL NUMBER <br /> PART I A � P � AN � I FOR REFEREN E ON LY SECTION SHEET SHEET <br /> S C A L E : I 8 " = I ' -0 " I v FROM oN <br /> / Hc D E Y I L TAKEN SHOWN <br /> (FI N. FLR.=75'-0") FACILITY DESIGN BY CE I DATE_07 , 02 , I 8_ <br /> � 0 4' 8' 16' 24' <br /> SYM REVISION BY APPD. DATE SYM REVISION BY APPD. DATE ACCEPTABILITY DRAWN BY DATE SUBTITLE LAST REVISION SYM DATE <br /> ❑ AUBURN, WA. 98002 THIS DESIGN AND/OR D. FARR P � UMB I NG BASEMENT P �AN <br /> RECORD DWG , - LOCKWOOD GREENE 03/94 EVERETT, WA. 98201 SPECIFICATION IS APPROVED �TGA�LI� 3i�i9� AREA I S SHEET oF <br /> ❑ KENT, WA. 98031 APPROVED BY DEPT. DATE E LAMB 3�2�92 TITLE O M I I � <br /> BOE,�� ❑ PORTLAND, OR. 97220 CHECKED • <br /> FACILITIES DEPARTMENT ❑ RENTON, WA. 98055 I Rc ���18�92 M E C H A N I C A � M A S T E R ��B N0. COMP.NO. <br /> ❑ SEATTLE, WA. 98124 f APPROVED ���18�92 91297.04/91431 .03 <br /> � DWG. N0. <br /> IAPPROVED � BLDG 40-37 COL C-D/12- 13 EVERETT 40-37- OM 1 15 <br /> L E 1/18/92 <br /> DESIGNER: " <br /> �r.� � � <br />