Laserfiche WebLink
�EGEND - <br /> ,:� .� <br /> 13 14� 15 <br /> GENERA� NOTES <br /> 1 .CONDUIT: ALL CONDUIT IS 1/2" EMT UNLESS <br /> OTHERWISE NOTED. CONDUIT BELOW 6' AFF IN �ACTORY <br /> AREAS WILL BE GALVANIZED RIGID STEEL <br /> � �fi 1 — 1 � � 2.CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, <br /> — — — — — ` — — — , � <br /> --- --- — ---- — --- -- � — ----- ----- — ----- — ° G INSULATION TYPE THHN/THWN, UNLESS NOTED <br /> 11/2»_4�16 1/2"-2�16 8 9 __� F,_ OTHERWISE. ' <br /> --- �s <br /> - --- � - -, <br /> - � — �—_ - ,fi+,�,;:4� � <br /> �8 MEN'S ����--� +�� �-��� ''.°� ��� r '':��.�''<� �;, � >`'���, � ��� � �� � � ,�''� �� `'.��Y`',i.`'�� �''...����,� �� � 3.COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH <br /> . ' _ j �R, � ri � '�'-•�� �il � �� . .,�ri� Y+.�� \�✓i ! :., �1 � %�; ����{ . i 4�' � ,.�., I 'v ���u ..1`� i� �>�d; ��� __ . _ . . . ,'� , . <br /> ,._-- �'� �, .: _� �..;, '�� �., �� x;i .�}. i�j I. �� � ���I., % .- �.-- <br /> I 8 WOM�EN'� 1 ;. � �'� '� � ��. �, ��� �- �, ��, DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH <br /> ,��` ,, ,x ,�, -� � �- = -- ;, � � � <br /> _,, r— , ; �' �����,�.�'�, ����� �y ����,� _�1 ��" ;',. ��,.� ,�;�,� ��,��.��, ,� �` �� � _ j' COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. <br /> ,, <br /> ; l_—_'—" . _. . �,r' C"' J.: i j I <br /> 'r�- �'' � � % :��"� �����''� '� � �� � - ' IDENTIFY INSULATED GROUND CONDUCTORS PER NEC <br /> �� � �'' � ��..% ,�- �,,,,,, `•,�, _, ; _ „ cv <br /> � ��- ,I � _ � WASH F UNTAIN 3 � � 2V30-1AH14�2 7 � �� ; � �, 250-57(b) EXCEPTION �1 ,b OR c (USING TAPE). COLOR <br /> �.__ : ; 29 � �, , �,�_ ' � <br /> 29 CODE AS FOLLOWS, • � <br /> ,; __�_ �� 120V-1 (TYP OF ,, �' � 29c � <br /> _� � <br /> �,__ ; i <br /> � �„G�E,. � ._� ,� — � � <br /> �-- , � � - -- _ � � 20V 77 , <br /> �_ , _ .—..� � _ -- � __ , <br /> , �� � <br /> ; ,�, ' <br /> �,__ �,i -_— � =� - � � - ,� � - _,�,,, -- -�.-�� —_ �' ,; <br /> t�-- ---��� (u�;cr,a� ;, -�� ! .�r,_ �--� �� ";�' !I- -__.. __i � <br /> , <br /> ` 208Y/1 480Y/2 V <br /> � � � �,��. <br /> _ <br /> � ----= —— — — — — — — — K <br /> ,- _; =� A EFT B S N P <br /> �, 9c ��, 29yc `__ � 29 � 29c �,� -- L I L BLAC BROWN <br /> , <br /> � ( U N <br /> � �� _ <br /> , _ � F ��--- � _� � B � CENTER BUS IN PNL RED ORANGE <br /> . <br /> - , ,- �. �_ - �. <br /> , <br /> I �`I__ r ,na.�, �; 2 5 `--- 2 5 �_-' 3 �4 �,�__2� t� 5 �,_ _.a z C � (RIGHT BUS IN PNL) BLUE GRAY <br /> j MiF <br /> �iJf <br /> 1 <br /> ' A� 1 11� � � . <br /> ' ,, o NEUTRAL WHITE YELLOW <br /> --_ �_ � -- ;- <br /> , <br /> �{:J. ?A: �d._i._F) �. '. <br /> I,. �."_ _` �� ., . '� .._�.— . ; .,-6�.--1.._._ _ _ �:.� �_l. <br /> --�-- ' -- -3� -. 3 - 3 �'� --_ - Q EQUIPMENT GROUND GREEN GREEN <br /> ,; � �, � <br /> �'� y� ;� z ISOLATED GROUND GRN�YEL* GRN�YEL* � � <br /> � � ��r f <br /> � o *GREEN WITH YELLOW TRACER <br /> ; -- i <br /> i <br /> I i <br /> , v �, _._ __ '_____ <br /> ,;L__ .-._._ ._"__ __._. 1 .— ., .Y — __ __ _ " __ "_ —_ _ __ _ _— — __ J . <br /> .__"_ �..___ _'_,� _ _ ...._ '___ __ __ ._._._ '.. _"" " __� —__ — "__ —__ � --.— —.._ -.... '__."_ _ .._.. __-:��. ___... <br /> �._. . . . __'__ ' _"__ .—,:� .. —: . . ... . .. � � .__. .._'_ _._. .. _ _ __ . . <br /> ,..'_ _"._.._r .: _ . — ._.. __ . __ 't�_ � .... . _ _ <br /> __— ___ .�'_ _ _'"_ "r ..__� '. � '_ �_ _ . <br /> _ ��_. .. _'_ __.:.i ..,..'" _ �' _ -'"'r— ". .,'�._ ' '.i .. <br /> � 4.DYMO LABEL ALL RECEPTACLES AND EQUIPMENT WITH <br /> 0 <br /> L` PANEL/ CIRCUIT ID. • <br /> i <br /> I <br /> z S.POST NEW PANEL SCHEDULES IN PANELS UPON , <br /> � COMPLETION OF JOB. <br /> � I I � <br /> Q 6.RETURN RED-LINE MARKUPS TO ENGINEERING UPON <br /> � COMPLETION OF JOB. � <br /> 7� 50VA 120/24VAC TRANSFORMER PER DETAIL 1 ON <br /> DRAWING 40-030-E500. `"� <br /> — - -- — -- — — — — — �— — — — —�- H , <br /> 8� 1/2"-2�16 TO 50VA TRANSFORMER. <br /> I <br /> RE �ERENCE DRAW NGS <br /> � , <br /> CONSTRUCTON NOTES <br /> I � PROVIDE NEW RECEPTACLE. , <br /> � CORE DRILL FLOOR SLAB FOR INSTALLATION OF NEW <br /> 1 /2" RIGID STEEL CONDUIT THROUGH FLOOR SLAB. � <br /> GROUT PENETRATION. <br /> I <br /> � INSTALL NEMA 5-15R RECEPTACLE IN PONY WALL <br /> COORDINATE EXACT LOCATION WITH WASH FOUNTAIN <br /> � SHOP DRAWINGS. � <br /> � ROUTE RACEWAY IN WALL � <br /> ;� <br /> � ROUTE CONDUIT (EMT) IN CEILING SPACE BELOW. <br /> � 6� CONNECT TO EXISTING HOMERUN. ; <br /> � 7� PROVIDE 20A-1 P GFCI CIRCUIT BREAKER TO SERVE <br /> WASH FOUNTAINS AND FLUSH VALVES (CIRCUIT 29c). <br /> � � MATCH LINE - FOR CONTINUATION SEE SHT M 1 E64 8� INSTALL AND WIRE TRANSFORMER (PROVIDED BY <br /> MECHANICAL) IN A SURFACE MOUNTED ENCLOSURE. _ <br /> 9� PROVIDE WIRING FROM FLUSH VALVE TO <br /> TRANSFORMER. <br /> P �AN �, 13 15 17 <br /> SCALE: 1/8�,_� ,_��, N � ���y ,;� �� * <br /> � <br /> M1E60 M1E61 M1E62 <br /> :� <br /> , �- — — <br /> M1E63 M1E64 M1E65 ' <br /> � _ <br /> KEY P �AN <br /> OFFMAN � W5741115 � SCALE: NONE * <br /> N G I N E E R S PHASE 1 RENOVATION PACKAGE <br /> 1101 2nd Ave., Suite 400�Seattie,WA 98101 IFC SUBMITTAL 8� 4' 0 4' 8' 16' <br /> ph 206.623.0717�fax 206.624.3775 <br /> coffman.com � 07.�2.�8 � <br /> L/�ST�NG creativity�resWts�relaGonships �����. � �8��—� �—��� , <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE J� DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> � • N� ACCEPTABILITY N. LAPRISE 07.02.18 <br /> �v as ����S�I�� THIS DESIGN AND/OR �HE�KEo PARTIAL 208Y/120V POWER PLAN W5741 1 15 0 R G 07.02.18 <br /> ORIG RESTROOM RENOVATION � G14 W5741115 CEI PWJ 07.02.18 ��' ��� � SPECIFICATION IS APPROVED P. JONES 07.02.18 SHEET <br /> � � � � BOE��� � ��� � �� �' � APPRovEo BY �EPr. �arE p. joNES o7.02.18 r�r�� WORKPLACE ENVIRONMENT INVESTMENT � <br /> ��E�KEo M 1 E 61 E 12 <br /> P. JONES O�.OZ.�H B U I L D I N G 40��0 JOB N0. COMP N0. ' <br /> � � � 83 ��. APPROVED �_ <br /> �� �IS�� 1� APPROVED DWG N0. <br /> �`�s E�� ELECTRICAL MASTER COL G-I/13-15 EVERETT, WA 40-030-M 1 E61 <br /> F���r�n�R <br />