My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1300 W MARINE VIEW DR 2016 Plans 2022-12-27
>
Address Records
>
W MARINE VIEW DR
>
1300
>
Plans
>
1300 W MARINE VIEW DR 2016 Plans 2022-12-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2022 3:35:58 PM
Creation date
8/12/2019 2:00:05 PM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
1300
Permit
PW0610-040
Year
2016
Notes
NORTH MARINA REDEVELOPEMENT INFRASTRUCTURE PHASE 1
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/�/ <br /> PROVIDE END PROVIDE FLAT PANE �BOARD 1 H 1 � EXISTING ) FEEDER SCHEDULE <br /> CAPS ON ALL PLATE FITfINGS <br /> ENDS AS REQUIRED 277/480 VOLT / 3 PHASE / 4 WIRE 200 AMP MCB MOUNTING: SURFACE <br /> SECTION: LUGS: ID N0. AMPERAGE SETS CONDUCTORS CONDUIT <br /> LOAD VA SERVES WIRE C.B. CKT PH CKT C.B. WIRE SERVES LOAD VA 2p2 20 AMP 1 (2) #10 CU. 2" <br /> 173� LIGHTS 20/1 1 � 2 40/3 TP1 , TP2, TP3 <br /> � 2130 LIGHTS 20/1 3 � 4 --- ------ O <br /> GALVANIZED 2130 LIGHTS 2�/1 5 � 6 --- ------ 502 50 AMP 1 (2) #8 CU. 2" <br /> FORMED STEEL SPACE 7 � 8 SPACE <br /> CHANNEL SPACE 9 � 10 SPACE <br /> SPACE 11 � 12 SPACE 503 50 AMP 1 (3) #6 CU. 2" <br /> SPACE 13 � 14 SPACE <br /> SPACE 15 � 16 SPACE <br /> P�ST BASE SPACE 17 � 18 SPACE 504 50 AMP 1 (4) #6 CU. 2" <br /> Y2"x45'CHAMFER <br /> SPACE 19 a 2� SPACE <br /> HANDHOLE �,.-� FINISHED SPACE 21 � 0 24 SPACE 507 50 AMP 1 (7) #6 CU. 2" <br /> i 3" MIN GRADE SPACE 23 <br /> ii <br /> � � �' �:`�:I f . . �1 I � ���� . -4• I I : �. . � .�- �---- <br /> � �� NOTES: <br /> ����'� � : . � . . e. � �.� � � .� . �d : . � .� \,�� �'\,�~������\,�'`��' INCLUDE CODE SIZED GROUND CONDUCTORS IN ALL <br /> �//�// // // /,j i i i � � i ' ,� .��' ./� l/ /,� ,�j' ,�e° \o <br /> TO LIGHTING �i \��\��� 1 I i i � � i�`���\� �,��'���\�o'�\ CONDUITS. <br /> HAN D H 0 LE 1 �f //\//�./ 1 � I i � � �/��/��/Oa��° <br /> OR ADDITIONAL --- \\.��\%---',�/ i i � �%°°`'�'�%�'`�/\ <br /> TRANSFORMER/ �--- -----�� �` (` CONCRETE PAD <br /> PANELBOARD � � <br /> \���`� TO TREE HANDHO�ES (QUANTITY P�`1�� �'1 SECTIONS: 1 SURFACE MOUNTED <br /> ` OF CONDUITS PER PLANS) 2os 120 V 1 PHASE 4 WIRE 40 A MCB LUGS: SINGLE NEMA 3R <br /> TYPE LOAD VA SERVES C.B. CKT CONNECTED PHASE �OAD CKT C.B. SERVES LOAD VA 7YPE <br /> F R 0 N T S i D E u 800 RECEPT - TREE WELL 20/ 1 1 1,600 2 20 / 1 RECEPT = TREE WELL 800 l.l <br /> U 600 RECEPT - TREE WELL 20/ 1 3 1,600 4 20 / 1 RECEPT TREE WELL 1,000 LI <br /> U 1,200 RECEPT - TREE WELL 20/ 1 5 1,200 6 20 / 1 SPARE N 0 T E S T H I S � H E ET. <br /> U 1,200 RECEPT - TREE WELL 20/ 1 7 1,200 8 20 / 1 SPARE <br /> � I T N T N PA NTI N <br /> E4.s $cA�: rv-rs 2,soo 2,soo 33.� �Ps �1 CONNECT LIGHTING CIRCUITS TO EXISTING BREAKERS IN <br /> PANEL 1 H1 . <br /> �2 PROVIDE NEW 40A 3P BREAKER IN PANEL 1 H 1 , MATCH <br /> PANELBOARD TP2 SECTIONS: 1 SURFACE MOUNTED EXISTING AIC RATING. <br /> 208 /120 V 1 PHASE 4 WIRE 40 A MCB LUGS: SINGLE NEMA 3R <br /> SQUARE D MINIZONE 'rrnE �ofw vn SERVES C.B. CKT CONNECTED PHASE l.OAD CKT C.B. SERVES LOAD VA n�E <br /> N EMA 3 R, 7.5 KVA LI 800 RECEPT - TREE WELL 20/ 1 1 800 2 20 / 1 SPARE <br /> 4-HO-ZU$�') 20V 1 9� U 800 RECEPT -- TREE WELL 20/ 1 3 800 4 20 / 1 SPARE <br /> HANDHOLE (TYPICAL) (NPICAL OF 3) �� soo RECEPT - TREE WELL 20/ � 5 600 s 20 / � SPARE <br /> IJ 600 RECEPT -- TREE WEl1 20/ 1 7 650 8 20 / 1 SPARE <br /> P E 503 AB �,400 �,450 ��.� �Ps <br /> TP1 TC <br /> PANEL <br /> 1 HV 502 <br /> 48C?V PANELBOARD TP3 SECTIONS: 1 SURFACE MOUNTED <br /> 208 120 V 1 PHASE 4 WIRE 40 A MCB LUGS: SINGLE NEMA 3R <br /> 5O4' TYPE LOAD VA SERVES C.B. CKT CONNECTED PHASE LOAD CKT C.B. SERVES LOAD VA TYPE <br /> TP2 TC u 600 RECEPT - TREE WELI. 20/ 1 1 600 2 20 / 1 SPARE <br /> BC ll 600 RECEP7 - TREE WELL 20/ 1 3 600 4 20 / 1 SPARE <br /> LI 400 RECEPT - TREE WELI. 20/ 1 5 400 fi 20 / 1 SPARE <br /> 5�2 LI 400 RECEPT - TREE WELL 20/ 1 7 450 8 20 / 1 SPARE <br /> 1,000 1,050 12.3 AMPS <br /> 504 TP3 TC <br /> CA <br /> - GROUND PER NEC {TYPICAL) <br /> STREET <br /> LIGHT <br /> REFER T4 PLANS FOR <br /> CIRCUITING REQUIREMENTS <br /> � � <br /> I-----�—� <br /> 2 N I A NOTE: <br /> E4.3 SCALE: NTS <br /> EARLY ROADWAY AND UTILITIES BID PACKAGE 13 ADJUST SCALES A CORDINGLY. ' <br /> PROJECT ENGINEER: S�: P O R T O F E V E R E T T DRAWING Na. <br /> � ' ' � 8/29/QS BID PACKAGE 13 - BID SEf p YD.Qpr� L BOYER NONE <br /> v i 'P D E S I G N E D 8 Y: Q A T E: E4■� <br /> Or O ENGf/NEER�,LLC $�s�os EARLY ROADWAY & UTI LITI ES � N 0 RT H M A R I N A R E D EV E LO P M E N T CIP N0. <br /> BID PACKAGE 13 STARR AUGUST 4, 2006 <br /> 17921 BOTHELL E1/EREfT HWY SE, 5��� ,05 � INFRASTRUGTURE PHASE 1 3-0-003-09 <br /> r� DRAWN BY: CHECKED BY: <br /> MILL CREEK, WASHINGTON 98012 qa 3/16/07 CONFORMED SET ADDENDA 1-4 � 55 �,�'4 �BCI( L BOYER L I G H T 1 N G D I A G R A N9 S NR�OJECT _ 5' � <br /> P.O. BOx 538 (425) 481-7735 FAX (425) 481-7692 ��,�5���'�� <br /> EVERETT wA 9s2o6 CONTACT: JOE GODWW ,�0 8/4/06 PERMIT APPROVAL/CONSTRUCTION qppRp�p gy: PD NM--200 O <br /> (425) 259-3164 JOB NUMBER: 005398 A N D P A N E L S C E Q U L E S <br /> N0. DATE BY REVlSION N0. DATE BY REVfSiON SHEEf N0. 7G OF 8J7 <br />