Laserfiche WebLink
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT <br /> ABBREVIATIONS � <br /> .. <br /> � . � a � a� � <br /> # POUND or NUMBER FL. FLOOR S. SOUTH - <br /> & AND FLASH. FLASHING S.C. SOLID CORE " Kidney Care <br /> (E) EXISTING FLUOR. FLUORESCENT S.C.D. SEAT COVER DISPENSER <br /> �- <br /> AT FT. FOOT or FEET S.D. SOAP DISPENSER <br /> - -- - -- - - _ _ ___ _ __ __- .- -__ _--- :; <br /> � c�� <br /> � DIAMETER or ROUND FTG. FOOTING S.N.D. SANITARY NAPKIN DISPENSER � <br /> 0 DIAMETER FURR. FURRING S.N.R. SANITARY NAPKIN �y � <br /> - CENTERLINE FUT. FUTURE RECEPTACLE - - <br /> - ANGLE S.S. STAINLESS STEEL � � � <br /> w ,�,�',� <br /> G.B. GRAB BAR S.SK. SERVICE SINK ■ ' : � � <br /> A.D. AREA DRAIN GA. GAUGE SCHED. SCHEDULE � _. � ?� � <br /> ACOUS. ACOUSTICAL GALV. GALVANIZED SECT. SECTION _ y � <br /> ACT. ACOUSTICAL TILE GL. GLASS SH. SHELF � � � � , <br /> ADJ. ADJUST,ADJUSTABLE or GND. GROUND SHR. SHOWER ~ � � ,� � <br /> ADJACENT GR. GRADE SHT. SHEET ' � <br /> � � � � <br /> AFF. ABOVE FINISH FLOOR GYP. GYPSUM SIM. SIMILAR �n �,y+ � <br /> AGGR. AGGREGATE _ "'�� � � � "' <br /> SPEC. SPEGFIED or SPECIFICATION -- <br /> AL. ALUMINUM H.B. HOSE BIBB SQ. SQUARE --� w v �� <br /> APPROX APPROXIMATE(LY) H.C. HOLLOW CORE STA. STATION `� �" --� � � <br /> ARCH. ARCHITECTURAL H.M. HOLLOW METAL STL. STEEL (F o r Te n a n t I m p rove m e n t P e rm i t O n I y} 4 ' � � <br /> A S B. A S B E S T O S HDWD. HARDWOOD STOR. STORAGE �,,� c.� � � <br /> HDWE. HARDWARE STRL STRUCTURE or STRUCTURAL - � cv <br /> ASPH. ASPHALT HORIZ. HORIZONTAL SUSP. SUSPENDED � v `� � <br /> HR. HOUR SYMM. SYMMETRICAL <br /> B.O.C. BOTTOM OF CONCRETE � W � � <br /> Z � <br /> F- � � <br /> . HEIGHT P ROJ E CT DATA P RO P E RTY OW N E R H E _ � � <br /> B.O.D. BOTfOM OF DECK T&G TONGUEAND GROOVE S ET I N D EX � <br /> B.O.M. BOTTOM OF MULLION I.D. INSIDE DIMENSION T. TREAD <br /> B.O.P. BOTTOM OF PANEL � Q � <br /> INSUL INSULATION or INSULATED T.B. TOWEL BAR � � <br /> B.O.R. BOTTOM OF REVEAL INT. INTERIOR T.C. TOP OF CURB `� � <br /> B/S. BUILDING STANDARD T.O.C. TOP OF CONCRETE General <br /> BD. BOARD APPLICABLE CODES SKOTDAL MUTUAL LLC <br /> JAN. JANITOR T.O.M. TOP OF MULLION G-000 COVER SHEET AND INDEX <br /> BITUM. BITUMINOUS JT. JOWT T.O.P. TOP OF PARAPET C/O SKOTDAL REAL ESTATE DAVE GRAEF, CCIM G-101 CODE COMPLIANCE AND LIFE SAFETY � <br /> BLDG. BUILDING T.O.R. TOP OF REVEAL CITY OF EVERETT, WASHINGTON 2707 COLBYAVENUE, SUITE 1200 PH: 425)252-5400 G-102 GENERAL NOTES - <br /> BLK. BLOCK BUILDING: 2015 INTERNATIONAL BUILDING CODE-WAC51-50 G-102A GENERAL NOTES <br /> K.O. KNOCK-OUT T.O.REC TOP OF DEEP RECESS EVERETT, WA 98201 FAX: (425)258-2473 G-103 ACCESSIBILITY DETAILS � <br /> BLKG. BLOCKING KIT. KITCHEN � 2015 INTERNATIONAL EXISTING BUILDING CODE dave.graef@skotdaLcom G-104 ACCESSIBILITY DETAILS <br /> BM. BEAM T.O.W. TOP OF WALL STRUCTURE: 2015 INTERNATIONAL BUILDING CODE <br /> BOT. BOTTOM LAB. LABORATORY T.P. TOP OF PAVEMENT MECHANICAL: 2015 INTERNATIONAL MECHANICAL CODE-WAC51-52 . <br /> LAM. LAMINATE(D) T.P.D. TOILET PAPER DISPENSER ELECTRICAL: 2005 NATIONAL ELECTRIC CODE (NFPA70) -= r <br /> C.B. CATCH BASIN LAV. LAVATORY T.V. TELEVISION PLUMBING: 2015 INTERNATIONAL PLUMBING CODE-WAC51-56 AND WAC51-51 <br /> C.G. CORNER GUARD TEL TELEPHONE FIRE/LIFE SAFETY: 2015 INTERNATIONAL FIRE CODE-WAC51-54 TE NAN T Architectural <br /> LKR. LOCKER _ <br /> C.I. CAST IRON LT. LIGHT TER. TERRAZZO ENERGY: 2015 ENERGY CONSERVATION CODE AD-101 DEMOLITION -REFLECTED CEILING AND FLOOR PLANS =_ ` <br /> C.O. CASED OPENING THK. THICK FUEL/GAS: 2015 INTERNATIONAL FUEL GAS CODE A-003 PARTITION TYPES <br /> C.O.M. CENTER OF MULLION TYP. TYPICAL ACCESSIBILITY: 2009 ICC/ANSI A117.1-2009 AMERICAN NATIONAL STANDARD A-101 ANNOTATED, DIMENSIONED FLOOR,AND ENLARGED PLAN & DETAILS ; <br /> M.C. MEDICINE CABINET A-130 REFLECTED CEILING DETAILS <br /> C.O.R. CENTER OF REVEAL M.O. MASONRY OPENING DAV I TA N E P H RO L O GY P RACT I C E AS S O C I AT E S A-131 REFLECTED CEILING, FINISHES AND FF&E PLANS - <br /> C.W. COLD WATER MAX. MAXIMUM U.O.N. UNLESS OTHERWISE NOTED OCCUPANCY CLASSIFICATION - -PER IBC CHAPTER 3 B A-401 MILLWORK ELEVATIONS, DETAILS, AND FINISH SCHEDULE <br /> CAB. CABINET UNF. UNFINISHED A-601 DOOR AND FINISH SCHEDULES, NOTES AND DETAILS <br /> MECH. MECHANICAL FIRE PARTITION-- PER IBC TABLE 508.4 N/A <br /> CEM. CEMENT(ITIOUS) MEMB. MEMBRANE UR. URINAL KRISTIN VIDETO ' <br /> CER. CERAMIC MET. METAL TYPE OF CONSTRUCTION - - -PER IBC 602 I-A 2000 16TH STREET PH: (253) 733-9820 <br /> CFCI. CONT. FURNISHED/CONT. MFR. MANUFACTURER VERT. VERTICAL SPRINKLERED YES DENVER, CO 80202 kristen.videto@davita.com - <br /> INSTALLED VEST. VESTIBULE <br /> CFOI. CONT. FURNISHED/OWNER. MH. MANHOLE NUMBER OF STORIES - J . <br /> MIN. MINIMUM <br /> INSTALLED M2CIlalIICaI - <br /> CLG. CEILING MIR. MIRROR W� WEST ASSESSOR'S PARCEL N0: --- - 00439162500100 <br /> DEFERRED SUBMITTAL <br /> MISC. MISCELLANEOUS W�C. WATER CLOSET A RC H I T E CT <br /> CLKG. CAULKING . � <br /> CLO. CLOSET MTD. MOUNTED W� WITH PROJECT SCOPE: THE SCOPE OF THIS PROJECT IS A TENANT IMPROVEMENT WHICH INCLUDES THE - <br /> MUL MULLION W�O WITHOUT DEMOLITION OF EXISTING PARTITIONS, ADD SUITE ENTRANCES FROM COMMON <br /> CLR. CLEAR WD. WOOD HALLWAY; CONSTRUCT OFFICES, EXAM, CONSULTATION, RECEPTION, WAITING, LAB, - <br /> CNTR. COUNTER WP WATERPROOF CONFERENCE, AND BREAK ROOMS; MODIFY MECHANICAL, ELECTRICAL, & PLUMBING W�E � -- <br /> COL. COLUMN N. NORTH VVSCT. WAINSCOT PER PLANS AND INSTALL MILLWORK& FINISHES. C OMB <br /> CONC. CONCRETE N.I.C. NOT IN CONTRACT EleCtl'ICaI __ <br /> CONN. CONNECTION N.T.S. NOT TO SCALE � WEIGHT DEFERRED SUBMITTAL � ' <br /> CONSTR CONSTRUCTION NO. NUMBER TENANT OCCUPANCY: LOREN VINE � � O <br /> . NOM. NOMINAL 3015 112TH AVE NE#205 P 425.670.6706 -- r N <br /> CONT. CONTINUOUS OFFICE (B) 2,004 S.F. BELLEVUE, WA 98004 F 425.774.8219 � � � <br /> CONTR. CONTRACTOR O.A. OVERALL Ivine@waremalcomb.com _ � � <br /> CORR. CORRIDOR O.C. ON CENTER Plumbing � W <br /> CPT. CARPET O.D. OUTSIDE DIAMETER DEFERRED SUBMITTAL <br /> CTR. CENTER OBS. OBSCURE J � � ' <br /> CTSK. COUNTER-SUNK OFCi. OWNER FURNISHED/CONT. -- � O <br /> INSTALLED - � � <br /> D. DEEP OFF. OFFICE �^ <br /> vJ rn <br /> D.F. DRINKING FOUNTAIN OFOI. OWNER FURNISHED/OWNER DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEERS OF RECORD ^ v <br /> INSTALLED G E N E RAL CO N TRACTO R U� ' z <br /> D.O. DOOR OPENING WHO SHALL REVIEW AND PROVIDE NOTATION INDICATING DOCUMENTS HAVE BEEN REVIEWED AND � � <br /> OPNG. OPENING FOUND TO BE IN GENERAL CONFORMANCE WITH THE BUILDING DESIGN. SUBMITTAL MATERIALS SHALL � ! <br /> D.S. DOWNSPOUT OPP. OPPOSITE INCLUDE PLANS, DETAILS AND CALCULATIONS PREPARED AND SIGNED BY A STATE REGISTERED � <br /> D.S.P. DRY STANDPIPE ENGINEER. � � � <br /> DBL. DOUBLE P.C. PRECAST CONTRACTOR SHALL SUBMIT ARCHITECT AND ENGINEER REVIEWED SUBMITTAL MATERIALS TO THE � � <br /> DEPT. DEPARTMENT BUILDING OFFICIAL FOR REVIEW AND PERMIT APPROVAL. DEFERRED SUBMITTAL ITEMS SHALL NOT BE � <br /> DET. DETAIL P��� PANEL JOINT INSTALLED PRIOR TO OBTAINING THE BUILDING OFFICIAL'S APPROVAL OF THE SUBMITTAL. AXIOMNW CONSTRUCTION JAMES BUCHANAN � ` <br /> DIA. DIAMETER P��M. PLASTIC LAMINATE 2232 BROADWAY, SUITE 101 PH: (206) 945-5227 r � <br /> P.T.D. PAPER TOWEL DISPENSER 1. AUTOMATIC FIRE SPRINKLER SYSTEM. <br /> EVERETT, WASHINGTON 98201 FAX: (425)405-3606 W <br /> DIAG. DIAGNONAL P.T.R. PAPER TOWER RECEPTACLE 2. FIRE ALARM SYSTEM. � <br /> DIFF. DIFFUSER james@axiomnw.com � <br /> DIM. DIMENSION PL PLATE 3. STEEL JOISTS, TRUSSES AND GIRDERS CONFORMING TO SJI STANDARDS SPECIFICATIONS. " <br /> PLAS. PLASTER 4. STEEL STAIRS, HANDRAILS AND GUARDS. -, O I"'� <br /> DISP. DISPENSER PLYWD. PLYWOOD 5. HIGH PILED STORAGE RACKING. _ � l� <br /> Ur <br /> DN. DOWN pR. PAIR 6. EXTERIOR BUILDING SIGNAGE. � � <br /> DR. DOOR 7. ANCHORAGE DESiGN FOR ALL ELECTRICAL EQUIPMENT REQUIRED. � <br /> PT. POINT 8. STOREFRONT AND CURTAIN WALL GLAZING SYSTEMS. �/ <br /> DWR. DRAWER PTN. PARTITION O �L <br /> E. EAST Q�T. QUARRY TILE � � <br /> SYMBOLS CONSULTANTS VICINITY MAP � � N � <br /> E.J. EXPANSION JOINT R. RISER W <br /> E.P. ELECTRIC PANELBOARD R.D. ROOF DRAIN <br /> E.W.C. ELECTRIC WATER COOLER R.O. ROUGH OPENING i I � <br /> EA. EACH � ALIGN A R FEROENCEEVATION = <br /> R.W.L. RAIN WATER LEADER � <br /> EL ELEVATION R A D. R A D I U S M E P E N G I N E E R � � <br /> ELEC. ELECTRIC(AL) REF. REFERENCE D XX B � > ' <br /> WB ENGINEERS&CONSULTANTS JIMMY SNEED � Q <br /> ELEV. ELEVATOR OFFICE� ROOM NAME SHEET NUMBER 4900 HOPYARD RD., SUITE 100 PH: 925 399-6687 <br /> REFR. REFRIGERATOR �� y� � W X � � <br /> EMER. EMERGENCY � ) w w w > w <br /> REINF. REINFORCE(D) 0000 ROOM NUMBER PLEASANTON, CALIFORNIA 94588 > > w -' Q � � ~'Z <br /> ENCL. ENCLOSED or ENCLOSURE C jsneed@wbengineering.com Q � W w w <br /> REQ. REQUIRED w > w > o Z 'Q cn � ' <br /> EQ. EQUAL Z � Q � Q � - ��! ' ! � <br /> RESIL. RESILIENT p � WALL MATERIAL TYPE � w � w � Q p W;� O ' <br /> EQPT. EQUIPMENT Y m Y W m � w , <br /> RGTR. REGISTER � Q U � U Y � Z j v � �, <br /> EXP. EXPANSION � � W A L L N OTE � � O O Q O Q w � W <br /> RM. ROOM � � c„> � p � � � � <br /> EXPO. EXPOSED F- �O Z <br /> RWD. REDWOOD DOOR NUMBER W �'�-� O <br /> � I <br /> EXST. EXISTING j' 101 C -�-- FLOOR MATERIAL TYPE L11 � I w�z cai�! <br /> EXT. EXTERIOR 52g I '� Q w� ' <br /> � �U � � i <br /> � � FLOOR NOTE <br /> ;,-';�I <br /> / <br /> � - <br /> F.A. FIRE ALARM � � � � W � � � <br /> � 'W o;o <br /> EXISTING DOOR PL MISC. MATERIAL TYPE <br /> � �.,,N.N <br /> F.B. FLAT BAR % � <br /> F.D. FLOOR DRAIN � CALIFORNIA ST � � o °' <br /> � TYPE NUMBER \ U o � � I <br /> F.E. FIRE EXTINGUISHER � � � , <br /> F.E.C. FIRE EXTINGUISHER CABINET "� ,�� KEYNOTE INDICATOR � �, <br /> / X DETAIL REFERENCE `, <br /> F.H.C. FIRE HOSE CABINET : ` <br /> F.O.C. FACE OF CONCRETE ``/ � SHEET NUMBER � \ _ � , , ; ' <br /> —� �� � � �"'�,, HEWITTAVE <br /> F.O.F. FACE OF FINISH X WALL TAG <br /> `, <br /> PA/PM: L. VINE <br /> F.O.M. FACE OF MULLION X REFERENCE ION , <br /> , � <br /> F.O.SH. FACE OF SHEATHING 7 � - � ' <br /> F.P. FIREPROOF <br /> XX SHEET NUMBER � FINISH INDICATOR DEC � 3 ZO�S \� DRAWN BY.: P.C.P. <br /> � F.S. FULL SIZE � <br /> CITY OF EVERET. JOB NO.: SEA18-6139-00 <br /> Y FDN. FOUNDATION �X �' --- PRO�ECT SITE ' <br /> o - ?ern�it �ervrc�� <br /> L FIN. FINISH(ED) X SECTION REFERENCE REVISION CLOUD & = <br /> DELTA NUMBER <br /> n` � SHEET NUMBER �•q- - SHEET Q <br /> � �� � � �� ��������`. <br /> � FIRE EXTINGUISHER o0 <br /> m� EXT. ELEVATION o CABINET W/FIRE �EVIEWED FOR ���� i � <br /> � � EXTINGUISHER � ' � ' <br /> � X REFERENCE PACIFIC AVE ,, � <br /> � ,�_�,��...,z� �Z�; �+ <br /> � � SHEET NUMBER � FE WALL-MOUNTED FIRE � o <br /> � <br /> -' EXTINGUISHER c�, <br /> U � <br /> NOT TO SCALE � <�v <br /> � lgt�� ot3 - � <br /> � <br />