ABBREVIATIONS DRAWING SYMBOLS BUILDING CODE SUMMARY - IRC LAND E z ! �
<br /> US /ZONING CODE SUMMARY � ;
<br /> � � � N �
<br /> W f o0 o�p
<br /> @ AT LAG BOLT + � BUILDING CODES USED ADDRESS: 4613 BAKER DR,EVERETT,WA 98203-1402 � j � �
<br /> AB ANCHOR BOLT LF LINEAR FOOT 'i4s.s7�E� • INTERNATIONAL RESIDENTIAL CODE(IRC)-2015
<br /> ABV ABOVE LL LIVE LOAD SPOT ELEVATION � �
<br /> NORTH ARROW WASHINGTON STATE ENERGY CODE(WSEC)-2015 � � Q 1�-
<br /> TAX PARCEL#: 00417400001200
<br /> AC AIR CONDITIONWG LT LIGHT � j � O
<br /> ADJ ADJUSTABLE LTG LIGHTWG 8 SIM � R302.6 DWELLING/GARAGE SEPARATION Q ' Qj o
<br /> ANCH ANCHOR LVR LOUVER BUILDING ELEVATION FLOOR ELEVATION LEGAL DESCRIPTION: SECTION 34 TOWNSHIP 29 RANGE 04 QUARTER SE DAVIDS MARINE ACRES BLK � -
<br /> � THE GARAGE SHALL BE SEPARATED AS FOLLOWS: 000 D-00-LOT 12 SD PLAT TGW EQ&UND 1/37 INT IN LOT 22(AKA COMM Z ; � N
<br /> APPROX APPROXIMATE(LY) LT WT LIGHT WEIGHT ,� 1 \ DRAWING NUMBER • MIN 1/2"GWB APPLIED TO GARAGE SIDE AT WALLS(1 HOUR RATING) ;
<br /> ARCH ARCHITECT(URAL) LVL MICROLAM LAMINATED A�-j,p� SHEET NUMBER E T WINDOW NUMBER • MIN 5/8"TYPE X GWB APPLIED TO THE CEILWG OF GARAGE PLAYGROUND RE5)SD PLAT&TGW ALL TDWS 2ND CLASS IN FRONT OF&ADJ Q � �
<br /> AUTO AUTOMATIC VENEER LUMBER � EG = EGRESS � TO SD LOT AS CONVYD BY ST OF WA EXC TH PTN IF ANY LY WHN R/W OF SEA& ' � � �
<br /> T= TEMPERED MIN 1/2"GWB AT STRUCTURES SUPPORTING THE GARAGE CEILING. MONTANA RR CO(GRRR)SUBJ ESE COE m���=�"�A o �
<br /> AW AWNING 8 SIM • MIN. 1 3/8"SOLID CORE DOOR,OR 20-MIN FIRE RATED DOORS,EQUIPPED WITH A SELF-CLOSING DEVICE. � ��� w ' � �
<br /> MAX MAXIMUM INTERIOR ELEVATION 1 p1 � � � �
<br /> BF BOTTOM FLUSH MECH MECHANICAL ^ DOOR NUMBER ZONE: R-S(RESIDENTIAL-SUBURBAN) }, _ ,
<br /> , DRAWING NUMBER R304 AND R305 ROOM DIMENSION REQUIREMENTS �
<br /> � � a�
<br /> BLDG BUILDING MED MEDIUM A�� SHEET NUMBER • GENERAL 7'-0"MINIMUM HABITABLE SPACE CEILING HEIGHT. USE CODE: 111 SINGLE FAMILY RESIDENCE-DETATCHED �` ' ° � � � i
<br /> BM BEAM MFR MANUFACTURER • 6'_8"MINIMUM CEILING HEIGHT IN BATHROOMS,TOILET ROOMS,OR LAUNDRY ROOM. E-- �
<br /> BOT BOTTOM MIN MINIMUM • SLOPED CEILING(MIN.5'-0"MUST MEET MINIMUM HEIGHT OVER 1/2 OF THE AREA.) � w �
<br /> BRG BEARING MISC MISCELLANEOUS �IM LOT SItE: 0.78 AC(33,976.8 SF) � U i qy � "
<br /> BUILDING SECTION • MINIMUM FLOOR AREA FOR A HABITABLE ROOM IS 70 SQ.FT.
<br /> BTWN BETWEEN MTL METAL � DRAWING NUMBER • 7'MINIMUM WIDTH FOR HABITABLE ROOM. w t Q p
<br /> MW MICROWAVE ` A101 LOT COVERAGE: �� `
<br /> �� SHEET NUMBER • BEAMS, GIRDERS, DUCTS, OR OTHER OBSTRUCTIONS IN BASEMENTS CONTAINING HABITABLE SPACES SHALL BE I- i .� �
<br /> FOOTPRINT AREA: 1 7 4 9 S F E X I S T I N G H O U S E � _ �
<br /> C C A S E M E N T PERMITTED TO PROJECT WITHIN 6'-4"OF THE FWISHED FLOOR. ; �
<br /> CB CATCH BASIN NEC NECESSARY ' o
<br /> CFM CUBIC FEET PER MINUTE NIC NOT IN CONTRACT SIM N/ALL SECTION R308 GLAZING PERMITTED AREA: MAXIMUM LOT COVERAGE = 35%(EMC 19.06.010) _ � � c ` '
<br /> CJ CEILING JOIST NTS NOT TO SCALE A�� D R A W I N G N U M B E R A L L G L A Z I N G I N H A Z A R D O U S L O C A T I O N S S H A L L R E C E I V E S A F E T Y G L A S S.T H E S A F E T Y G L A S S D E S I G N A T I O N S H A L L B E 1749 SF 0 - ° < ° � V i '
<br /> CLG CEILING �� SHEET NUMBER VI5IBLY MARKED ON EACH WINDOW AS REQUIRED BY CODE.THE FOLLOWING AREAS ARE HAZARDOUS LOCATIONS AND T TAL -5.1/0 35/o,THEREFORE OKAY � ,
<br /> CLR CLEAR 0/ OVER SHALL RECEIVE SAFETY GLASS: FRONT YARD SETBACK: W Q I
<br /> CNTR CENTER OD OUTSIDE DIAMETER • GLAZING IN DOORS. MIN.REQ'D: 20'-0" �
<br /> COL COLUMN OC ON CENTER /�� SIM STRUCTRAL DETAIL • GLAZING WITHW 24"ARC OF EITHER VERTICAL EDGE OF DOOR IN A CL05ED POSITION AND WHERE BOTTOM EXPOSED PROPOSED: 20'-0"EXISTWG COMPLIANCE,THEREFORE OKAY
<br /> CONC CONCRETE OH OVERHEAD � �� DRAWING NUMBER EDGE OF THE GLAZWG IS LESS THAN 60"AFF. '
<br /> CONST CONSTRUCTION OPP OPPOSITE A101 SHEET NUMBER • GLAZWG IN WINDOWS THAT MEETS ALL OF THE FOLLOWING: `'�1�:� I �I �F-�; �
<br /> CONT CONTINUOUS OV OVEN • A)THE EXPOSED AREA 6F AN INDIVIDUAL PANE IS LARGER THAN 9 SF. � � H '��!I a= .Y
<br /> CONTR CONTRACTOR • B)BOTTOM EDGE OF THE GLAZING IS LESS THAN 18"AFF WEST SIDE SETBACK: ,
<br /> COORD COORDINATE PC PIPE COLUMN SIM MIN.REQ'D: 5'-0" �f���I --
<br /> ARCHITECTURAL DETAIL • C)THE TOP EDGE OF GLAZING IS MORE THAN 36"AFF ���� I
<br /> PLAM PLASTIC LAMINATE � PROPOSED: 5'-0"EXISTING COMPLIANCE,THEREFORE OKAY � I
<br /> D DRYER PLYWD PLYWOOD A101 DRAWING NUMBER • D)ONE�R MORE WALKING SURFACES ARE WITHIN 36"MEASURED HORIZONTALLY AND IN A STRAIGHT LINE OF THE �
<br /> � SHEET NUMBER GLAZING. �i- E �LF _�;_� v�' ��
<br /> DB DROP BEAM PSF POUNDS PER SQUARE FOOT • GLAZING AT WET SPACES WHERE THE BOTTOM OF EXPOSED ED6E OF THE GLAZING IS LESS THAN 60°(EXCEPTION: � �r'k= � ���a" t
<br /> EAST SIDE SETBACK:
<br /> DEMO DEMOLITION PSI POUNDS PER S�UARE INCH FOR GLAZING THAT IS MORE THAN 60"MEASURED HORIZONTALLY AND IN A STRAIGHT LINE,FROM THE WATER'S MIN.REQ'D: 5'-0" %
<br /> DHW DOMESTIC HOT WATER HEATER PSL PARALLAM PARALLEL EDGE OF A BATHTUB). PROPOSED: 5'-0"EXISTING COMPLIANCE,THEREFORE OKAY
<br /> DIA DIAMETER STRAND LUMBER • GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36"ABOVE THE PLANE OF THE '
<br /> DIM DIMENSION PT POINT ADJACENT WALKING SURFACE OF STAIRWAY. I �
<br /> DL DEAD LOAD PT PRESSURE TREATED G E N E RAL N OTE S REAR YARD SETBACK: �I;
<br /> DN DOWN PTD PAINTED R310 EMERGENCY ESCAPE AND RESCUE OPENWGS(EERO'S) MIN.REQ'D: 20'-0"
<br /> DRY DRYER PWR POWER • IN BASEMENTS,EERO'S ARE REQUIRED IN EACH SLEEPING ROOM.THIS OPENING SHALL HAVE MAX CLEAR OPENWG PROPOSED: 20'-0"EXISTING COMPLIANCE,THEREFORE OKAY �
<br /> DS DOWNSPOUT SILL HEIGHT OF 44"AFF,AND IT SHALL OPEN DIRECTLY INTO A PUBLIC WAY OR TO A YARD THAT OPENS TO PUBLIC
<br /> DW DISHWASHER QTY QUALITY 1. IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT ALL WORK COMPLY WITH THE 2015 SEATTLE RESIDENTIAL WAY� HEIGHT LIMIT: I
<br /> DWG DRAWING �UANT QUANTITY CODE,THE WASHINGTON STATE ENERGY CODE,AND OTHER APPLICABLE CODES,RULES,AND REGULATIONS OF • ALL EERO'S SHALL HAVE A NET CLEAR OPENING OF 5J SQUARE FEET,WITH MIN.NET CLEAR HEIGHT OF 24"AND ALLOWED: 2g'_p" i
<br /> JURISDICTIONS HAVWG AUTHORITY MIN. NET CLEAR WIDTH OF 20".
<br /> EW EACH WAY R RANGE 2. GENERAL CONTRACTOR SHALL COORDINATE A PRE-CONSTRUCTION SITE MEETING WITH OWNER,ARCHITECT AND • EERO'S SHALL BE OPERATIONAL FROM INSIDE THE R�OM W/OUT THE USE OF KEYS,TOOLS OR SPECIAL KNOW�EDGE. PROPOSED: 23'-4"EXISTWG FROM AVERAGE GRADE,NO CHANGE II �'
<br /> E EXISTING RD ROOF DRAIN OTHER DESIGN CONSULTANTS,AS REQUIRED.
<br /> EA EACH REINF REINFORCING 3. GENERAL CONTRACTOR SHALL VERIFY EXISTWG GRADE CONDITIONS AND HEIGHT LIMITS WITH ARCHITECT ON SITE • MIN. HORIZONTAL AREA OF WINDOW WELLS SHALL BE 9 S�UARE FEET,WITH MIN.PROJECTION AND WIDTH OF 36". BUILDING SQUARE FOOTAGE: '
<br /> EG EGRESS RE�'D REQUIRED PRIOR TO BEGINNING OF W�RK AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCT IN THE SITE SURVEY AND/OR THE WINDOW WELL SHALL ALLOW THE EERO'S TO BE FULLY OPENED. BASEMENT: 888 SF �
<br /> ELEC ELECTRICAL REF REFRIGERATOR OTHER DRAWINGS. MAIN LEVEL: 1749 SF ,
<br /> EM ELECTRIC METER REV REVISION 4. PRIOR TO COMMENCEMENT OF ANY PORTION OF THE WORK,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF 311.7 STAIRWAYS UPPER LEVEL: 960 SF
<br /> EQ EQUAL RF ROOF ANY DISCREPANCIES NOTED AMONG OR BETWEEN THE CONTRACT DOCUMENTS,OWNER-PROVIDED INFORMATION, • STAIRWAYS SHALL NOT BE LESS THAN 36"MIN.CLEAR,ABOVE THE PERMITTED HANDRAIL HEIGHT. GARAGE: 441 SF
<br /> EQUIP EQUIPMENT RFG ROOFWG SITE CONDITIONS, MANUFACTURER RECOMMENDATIONS,OR CODES,REGULATIONS, OR RULES OF JURISDICTIONS • MIN. HEADROOM IN ALL PARTS OF THE STAIRWAY SHALL NOT BE LESS THAN 6'-8" i
<br /> EXH EXHAUST RM ROOM HAVING AUTHORITY. • A FLIGHT OF STAIRS SHALL NOT HAVE A VERTICAL RISE LARGER TNAN 147" i
<br /> EXIST EXISTING RO ROUGH OPENING 5. PRIOR TO COMMENCEMENT OF ANY PORTION OF THE WORK,THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE • MAX.RISER HEIGHT IS 7 3/4".OPEN RISERS ARE ALLOWED WITH OPENING BETWEEN TREADS THAT DOES NOT PERMIT PARKING:
<br /> EXP EXPANSION CONTRACT DOCUMENTS,OWNER-PROVIDED INFORMATION,AND SITE CONDITIONS,WCLUDING TAKING AND THE PASSAGE OF A 4"DIA.SPHERE. REQUIRED: 2 PER DWELLING(EMC 19.34.020) '
<br /> EXT EXTERIOR S 51NK VERIFYING FIELD MEASUREMENTS AS NECESSARY. • MIN.TREAD DEPTH IS 10".A NOSWG IS NOT RE�UIRED WHERE TREAD DEPTH IS MIN. 11". PROPOSED: 2(NO CHANGE)
<br /> SC SOLID CORE 6. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL GOVERNMENTAL PERMITS,FEES,LICENSES,AND INSPECTIONS • LANDWG WIDTH SHALL BE NO LESS THAN THE WIDTH OF STAIRWAY,AND MIN.36"DEPTH. SURVEY:
<br /> FD FLOOR DRAW SCH SCHEDULE NECESSARY FOR PROPER EXECUTION AND COMPLETION OF THE WORK,EXCEPT FOR THE GENERAL BUILDING PERMIT. • HANDRAIL HEIGHT,MEASURED VERTICALLY,SHALL BE BETWEEN 34"AND 38".HANDRAILS SHALL BE CONTINUOUS REQUIREMENTS: FOR ALL NEW BUILDWGS,ADDITIONS,OR ALTERATIONS OF EXISTING BUILDINGS, II
<br /> FDN FOUNDATION SCHED SCHEDULE 7. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY.WHAT IS REQUIRED BY ONE SHALL BE BINDING AS IF REQUIRED FOR FULL FLIGHT.HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS.TYPE I HANDRAILS THE PLANNING DIRECTOR AND BUILDING OFFICIAL SHALL BOTH HAVE THE _ �
<br /> FIN FINISH SECT SECTION BY ALL. THAT DO NOT HAVE A CIRCULAR CROSS SECTION SHALL HAVE A PERIMETER BETWEEN 4"AND 61/4",WITH A MAX INDEPENDENT AUTHORITY TO REQUIRE THE APPLICANT TO HAVE A SURVEY � W I
<br /> FJ FLOOR JOIST SF SQUARE FOOT 8. REPETITIVE FEATURES NOT INDICATED IN THE DRAWINGS EVERYWHERE THAT THEY OCCUR SHALL BE PROVIDED AS IF CROSS-SECTION OF 2/14"AND MIN.0.01"RADIUS-EDGE. COMPLETED TO VERIFY THAT THE SETBACK AND HEIGHT STANDARDS ARE MET. � I �
<br /> FL FLOOR SG SAFETY GLAZING DRAWN IN FULL. WHERE THE PROPOSED BUILDING,ADDITION,OR ALTERATION IS WITHIN ONE FOOT = �
<br /> FO FACE OF SH SINGLE HUNG 9. DO NOT SCALE THE DRAWINGS.LARGE SCALE DIMENSIONS GOVERN SMALL SCALE DIMENSIONS,GENERAL R312 GUARDS AND WINDOW FALL PROTECTION � �
<br /> FT FOOT SIM SIMILAR CONRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCY IN DIMENSIONS,PRIOR TO PROCEEDING WITH WORK. OF A REDUIRED SETBACK OR WITHIN ONE FOOT OF THE MAXIMUM ALLOWABLE �
<br /> • GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING SURFACES, INCLUDING STAIRS,RAMPS AND LANDWGS, z
<br /> HEIGHT,THE PLANNING DIRECTOR AND BUILDING OFFICIAL SHOULD ALWAYS W
<br /> FTG FOOTWG SI SLIDING WINDOW OR DOOR 10. AT NEW CONSTRUCTION,ALL DIMENSIONS ARE TO FACE OF FRAMING,FACE OF CONCRETE,CENTER LINE OF THAT ARE LOCATED MORE THAN 30"MEASURED VERTICALLY TO THE FLOOR/GRADE BELOW. Z n w o � I
<br /> REQUIRE A FULL OR LIMITED SURVEY,UNLESS EXTRAORDINARY CIRCUMSTANCES Q � � � � �
<br /> FURN FURNACE SPEC SPECIFICATION COLUMNS,AND CENTERLINE OF WINDOWS AND DOORS,U.N.O., • MIN GUARD HEIGHT SHALL BE 36".WHERE THE TOP OF GUARDS ALSO SERVE AS A HANDRAIL ON THE OPEN SIDE OF JUSTIFY OTHERWISE. W � o � Q �
<br /> SPF SPRUCE,PINE,FIR 11. AT EXISTING CONSTRUCTION,DIMENSIONS ARE TO FINISH FACE OF MATERIALS U,N.O.. STAIRS,T0.0 GUARDS SHALL BE BETWEEN 34"AND 36" W y ¢ � � �
<br /> 12. SEE SP EC I F IC A T I O N S B O O K F O R R E Q U I R E D S H O P D R A W I N G S.G E N E R A L C O N T R A C T O R S H A L L P R E P A R E A N D S U B M I T O P E N I N G S I N G U A R D S S H A L L N O T A L L O W P A S S A G E O F A 4"D I A.S P N E R E.T H E T R I A N G U L A R O P EN IN G AT THE SIDE OF � W W m � Z ¢ I �
<br /> GA GAUGE,GAGE S SQUARE .
<br /> GALV GALVANIZED SQ FT SaUARE FOOT SHOP DRAWINGS TO ARCHITECT;AFTER ARCHITECT'S REVIEW,TO GOVERNING AUTHORITY. OPEN STAIRS SHALL NOT ALLOW PASSAGE OF A 6"DIA.SPHERE. � � �
<br /> 13. T H E I N TENT OF ARCHITECTURAL DRAWINGS,DETAILS AND SPECIFICATIONS IS TO SHOW DESIGN APPROACH.IT IS THE WHEN THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72"ABOVE FINISH GRADE BELOW,THE � � w o ¢ '
<br /> GC GENERAL CONTRACTOR SQIN SQUAREINCH .
<br /> GEN GENERAL 5S STAINLESS STEEL GENERAL CONTRACTOR'S RESPONSIBILITY AND BAILIWICK TO PROPERLY INSTALL AND EXECUTE A STRUCTURALLY LOWEST PART OF CLEAR OPENING SHALL BE MIN.24"AFF.IF CLEAR OPENING IS LESS THAN 24",MAX WINOOW '
<br /> GL GLASS S&R SHELF AND ROD SOUND,WATER AND AIR PROOFED,DURABLE PROJECT. OPENING SHALL NOT ALLOW PASSAGE OF A 4"DIA.SPNERE. 'i
<br /> GM GAS MEfER STD STANDARD i
<br /> R314 SMOKE DETECTORS/R315 CARBON MONOXIDE ALARM REVISIONS DATE DESCRIPTION
<br /> GR GRADE STL STEEL PROVIDE A SMOKE DETECTOR AND CARBON MONOXIDE IN THE FOLLOWING LOCATIONS: I
<br /> GWB GYPSUM WALL BOARD STRUCT STRUCTURAL IN EACH SLEEPING ROOM. �
<br /> SYM SYMMETRICAL . I
<br /> HB HOSE BIB • OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. '
<br /> HC HOLLOW CORE TF TOP FLUSH • MINIMUM ONE AT EACH STORY OF THE DWELLING INCLUDWG BASEMENT.
<br /> HDR HEADER T&G TONGUE AND GROOVE VE NTI LATI 0 N EXHAU ST & IA THERMOSTATS I
<br /> HDW HARDWARE TEMP TEMPORARY,TEMPERATURE Q NOTES ENERGY CODE REQUIREMENTS
<br /> HORIZ HORIZONTAL THK THICK � � • PROVIDE MIN. (1)ONE PROGRAMMABLE THERMOSTAT FOR THE REGULATION OF TEMPERATURE.
<br /> HR HOUR(FIRE RESISTANT RATING) TOC TOP OF CONCRETE • THERMOSTAT TO ABIDE BY SECTION R403.1.1 OF THE 2015 WASHINGTON ENERGY CODE.
<br /> HT HEIGHT TOG TOGETHER REFERENCE IRC CHAPTER 15 II, ' ,
<br /> HVAC HEATING,VENTILATION&AC TOW TOP OF WALL DUCT LEAKAGE TEST WSEC(2015 EDITION):TABLE 402.1.1 PRESCRIPTIVE ENERGY CODE COMPLIANCE FOR CLIMATE ZONE MARINE 4
<br /> TYP TYPICAL 1. THE BUILDING SHALL BE EQUIPPED WITH A SOURCE SPECIFIC AND WHOLE HOUSE VENTILATION SYSTEMS. THIS ALL DUCTS/AIR HANDLERS ARE LOCATED INSIDE THE BUILDING ENVELOPE AND DO NOT REQUIRE TESTING PER
<br /> IG INSULATED GLASS SYSTEM USES AN ENERGY/HEAT RECOVERY VENTILATOR(SEE PLANS),VENTILATION AMOUNT TO BE DETERMINED BY EXCEPTION FOUND IN SECTION R403.2.2 OF THE 2015 WASHINGTON ENERGY CODE. GLAZED FENESTRATION U-FACTOR 0.30 NFRC '
<br /> IN INCH UNO UNLESS NOTED OTHERWISE IRC M1508.2/.3 LIGHTING EQUIPMENT SKYLIGHT U-FACTOR 0.50 NFRC
<br /> INCL INCLUDING UON UNLESS OTHERWISE NOTED 2, SOURCE SPECIFIC EXHAUST VENTILATION SHALL BE REQUIRED IN EACH KITCHEN,BATHROOM,WATER CLOSET, • A MINIMUM OF 75%OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURE SHALL BE HIGH-EFFICACY LAMPS
<br /> INFO INFORMATION LAUNDRY ROOM,INDOOR SWIMMING POOL,SPA,AND OTHER ROOMS WHERE WATER VAPOR OR COOKING ODOR IS PER SECTION R404.1 OF THE 2015 WASHINGTON ENERGY CODE. FENSTRATION U-FACTOR 0.30
<br /> INSUL INSULATING,INSULATION VAR VARIES PRODUCED. CEILING R-VALUE R-49
<br /> INT INTERIOR VENT VENTILATION 3. EXHAUST AIR fROM BATHROOMS AND TOILET ROOMS SHALL BE EXHAUSTED DIRECTLY OUTDOORS. M1507 EXHAUST FANS
<br /> ISG INSULATED SAFETY GLASS VERT VERTICAL 4. KITCHENS SHALL VENT AT 100 CFM INTERMITTENT OR 25 CFM CONTINUOUS. EXHAUST FAN TO VENT DIRECTLY TO THE EXTERIOR.CFM REQUIREMENTS TO MEET THE MINIMUM FOR THE FOLLOWING VAULTED CEILING R-VALUE R-38
<br /> VG VERTICAL GRAIN 5. BATHROOMS,TOILET ROOMS, LAUNDRY ROOMS AND SIMILAR SPACES SHALL VENT AT 50 CFM INTERMITTENT OR 20
<br /> JT JOINT VIF VERIFY IN FIELD CFM CONTINUOUS. LOCATIONS: ISSUANCES
<br /> 6, ALL VENTILATION SYSTEM CONTROLS SHALL BE READILY ACCESSIBLE. SOURCE SPECIFIC SYSTEMS SHALL BE • 50 CFM AT BATHROOM-TOILET ROOMS,LAUNDRY ROOMS,INDOOR SWIMMING POOLS,AND SPAS, WOOD FRAMED WALL R-VALUE R-21 INT
<br /> M
<br /> KD KILN DRIED WASHER • 100 CFM AT KITCHENS. BELOW-GRADE WALL R-VALUE `*10/15/21 +TB DATE DESCRIPTION
<br /> KP KING POST W/ WITH CONTROLLED BY MANUAL SWITCHES,DEHUMIDISTATS,TIMERS OR OTHER APPROVED MEANS. INTERMITTENTLY • ONE 100 CFM WHOLE HOUSE EXHAUST FAN.
<br /> W/0 WITHOUT OPERATED WHOLE HOUSE VENTILATION SYSTEMS SHALL HAVE THE CAPABILITY FOR CONTINUOUS OPERATION,AND _
<br /> SHALL HAVE A MANUAL TIMER AND AN AUTOMATIC CONTROL,SUCH AS A CLOCK TIMER IF RE�UIRED. FLOOR R-VALUE R-30/U=0.029
<br /> LAM LAMINATED(D) WASH CLOTHES WASHER COORDINATE ALL EXTERIOR PENETRATIONS WITH ARCHITECT. 07.13.2017 AS-BUILT PLANS
<br /> 7. ALL EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. EXHAUST DUCTS SHALL BE EQUIPPED WITH BACK- REFER TO ENERGY CODE SECTION FOR WHOLE HOUSE VENTIALTION. SLAB ON GRADE R-VALUE&DEPTH R-10 2' 09.19.2017 SD PRICING SET
<br /> LAV LAVATORY WD WARMING DRAWER DRAFT DAMPERS. EXHAUST DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-4.
<br /> WM WATER METER 8. THE BUILDING SHALL BE EQUIPPED WITH A WHOLE HOUSE VENTILATION SYSTEM CAPABLE OF A MINIMUM OF THE CFM
<br /> WS WIRE SHELVING LISTED IN THIS PROJECT(SEE FLOOR PLANS), SYSTEM SHALL SUPPLY OUTSIDE AIR VIA FRESH AIR INTAKE AT THE M1507 VENTILATION INT-(intermediate framing)denotes standard framing 16 inches on center with heatlers insulated with a minimum of R-10 insulation. 12.05.2017 PERMIT SUBMITTAL SET
<br /> WWM WELDED WIRE MESH HEAT RECOVERY VENTILATOR SYSTEM. ALL DUCTWORK IN A HEAT RECOVERY SYSTEM SHALL BE SIZED AND INSTALLED PROVIDE OUTSIDE AIR AT EACH HABITABLE ROOM WITH INDIVIDUAL INLET AT WINDOWS,TYP.COORDINATE WITH
<br /> PER THE MANUFACTURER'S INSTRUCTIONS. A FILTER MUST BE INSTALLED ON THE UPSTREAM SIDE OF THE HEAT ARCHITECT. '" "10/15/21 +TB"means R-10 continuous insulation on the exterior of the wall,or R-15 on the continuous insulation on the interior T
<br /> # NUMBER OF POUND(5) of the wall,or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall.
<br /> EXCHANGER IN BOTH THE INTAKE AND THE EXHAUST AIRSTREAMS WITH A MINIMUM EFFICIENCY RATING(MERV)OF 6. "10/15/21 +TB"shall be permitted to be met with R-13 caviry insulation on the interior of the basement wall plus R-5 continuous
<br /> 9. AIR INLETS SHALL NOT BE LOCATED CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET OR PLUMBING VENT NOTES insulation on the interior or exterior of the wall."TB"means thermal break between floor slab and basement wall.
<br /> (UNLESS VENT QUTLET IS 3'ABOVE THE OUTDOOR AIR INLET),WHERE OBJECTIONABLE ODORS,FUMES OR VAPORS MAY • ALL CODE SUMMARIES ABOVE ARE FOR REFERANCE ONLY PLEASE REFER TO THE BUILDING DEPARTMENT FOR
<br /> BE PICKED UP,IN A HAZARDOUS OR UNSANITARY LOCATION,IN A ROOM OR SPACE HAVING FUEL-BURNING FURTHER DETAILS ADVANCED FRAMING ALLOWS FULL DEPTH ACROSS ENTIRE SURFACE.INSTALL R-49 IF INSULATION IS REDUCED AROUND
<br /> APPLIANCES,OR IN AN ATTIC,CRAWL SPACE OR GARAGE.
<br /> CEILING PERIMETER
<br /> 10. WHOLE HOUSE FANS LOCATED FOUR FEET OR LESS FROM INTERIOR GRILL SHALL HAVE A SONE RATING OF 1.0 OR LESS �
<br /> MEASURED AT 0.1 INCHES WATER GAUGE.
<br /> CREDIT SELECTION: PER WSEC CHAPTER 5:ALTERATIONS(REMODELS)DO NOT NEED TO OBTAIN ENERGY CREDITS FROM �
<br /> 11. WHOLE HOUSE VENTILATION SHALL BE DUCTED TO ALL MAIN HABITABLE ROOMS, ALL INTERIOR DOORS SHALL BE TABLE R406.2.ADDITIONS MUST MEET REQUIREMENTS OF NEW CONSTRUCTION.
<br /> UNDERCUT MIN 1/2"ABOVE FINISH FLOOR COVERING.
<br /> COPYRIGHT BOARD AND VELLUM LLQ ALL RIGHTS RESERVED.
<br /> ORIGINAL SHEET SIZE IS 22"x3q"
<br /> . A OUTSIDE AIR INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED AND LOCATED PER THE INTERNATIONAL LIGHTING: MINIMUM 75%OF PERMANENTLY INSTALLED LAMPS IN LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS.
<br /> MECHANICAL CODE.
<br /> BOARD &VELLUM PROJECT#: 2016170.00
<br /> 1 . VENT ALL EXHAUST FANS TO THE OUTSIDE. EXHAUST DUCTS ARE TO BE CONSTRUCTED OF SMOOTH BORE DUCTWORK: DUCTWORK IN UNCONDITIONED SPACES SHALL BE INSULATED W/R-8 INSULATION,MIN. SDCI PROJECT#: XXXX)00(X
<br /> NONCOMBUSTIBLE MATERIAL AND ARE TO BE INSULATED AS REQUIRED BY CODE. DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR AND HOMEOWNER PRIOR TO
<br /> 14. VENTILATION DUCT FOR THE DRYER SHALL BE 4"DIAMETER METAL WITH A SMOOTH INTERIOR AND PROVIDED WITH A B U I LD I N G AREA CALC U LATI O N S AN APPROVED FINAL INSPECTION. PLOT DATE: DECEMBER 5, 2017
<br /> BACKDRAFT DAMPER CONCEALED IN CONSTRUCTION. INSTALL DRYER AND EXHAUST PER DRYER MANUFACTURER'S
<br /> INSTRUCTIONS,
<br /> ENERGY: EACH DWELLING UNIT IS REQUIRED TO BE PROVIDED WITH AT LEAST ONE PROGRAMMABLE THERMOSTAT FOR
<br /> 15. EXHAUST HOaD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF 400 CFM SHALL BE PROVIDED WITH MAKEUP AIR AT EXISTING TO REMAIN NEW EXISTING + NEW THE REGULATION OF TEMPERATURE.
<br /> A RATE APPROXIMATELY E�UAL TO THE EXHAUST AIR RATE.SUCH MAKEUP AIR SYSTEMS SHALL BE EQUIPPED WITH A
<br /> MEANS OF CLOSURE AND SHALL BE AUTOMATICALLY CONTROLLED TO START AND OPERATE SIMULTANEOUSLY WITH CONDITIONED SPACE(INTERIOR) NOTE:A RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE COMPLYING WITH SEC 401.3 IS REQUIRED TO BE COMPLETED BY A
<br /> THE EXHAUST SYSTEM. BASEMENT 888 0 888 DESIGN PROFESSIONAL OR BUILDER AND PERMANENTLY POSTED WITHIN 3'OF THE ELECTRICAL PANEL PRIOR TO FINAL PROJECT INFORMATION
<br /> FIRST FLOOR 1749 0 1749 INSPECTION T
<br /> SECOND FLOOR 960 0 960
<br /> BUILDING AIR LEAKA6E AND TESTING SHEET NO.:
<br /> TOTALS 3597 0 3597 THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO LIMIT AIR LEAKAGE AND BE TESTED AND VERIFIED AS HAVING
<br /> AN AIR LEAKAGE RATE BELOW 5 AIR CHANGES PER HOUR PER SECTION R402.4 OF THE 2015 WASHINGTON ENERGY CODE.
<br /> �