Laserfiche WebLink
_i� ' <br /> FASTENING SCHEDULE MATERIAL LIST <br /> WA�LS: FLOOR: ROOF: <br /> PLATE—TO—STUD MIN. OF 3— 0.121" x 3" NAILS 2 x 8 FLOOR JOIST—TO—RIM MIN. OF 4— 0.131" x 3" NAILS (SENCO KC27 OR EQUAL) ROOFING. . . . . . . . . . . . .ARCH. SHINGLES OVER SELF—ADHERED <br /> UNDERLAYMENT APPLIED SHINGLE FASNION <br /> VW TACKBOARD—TO—STUD O WTERIOR 16 ga x 2" WIDECROWN STAPLES (SENCO P21) C� 6" oc TOP & BOTTOM C�ASS "A" BOTTOM BOARD—TO—JOIST 16 ga. x 3/8" WIDE CROWN C�? 12"oc MAX. —HIGH WIND APPUCATION— <br /> AND GLUED IN FIELD —DRIP EDGE SHALL BE PROVIDED AT EAVES AND <br /> FLOOR DECKING—TO-2x JOIST 0.113" x 2 3/8" RING SHANK Q 6"oc EDGE, 12"oc FIELD <br /> SHEETROCK—TO—STUD @ INTERIOR 0.091 x 2Ya" NAILS AT 16" oc EDGE AND CONSTRUCTION ADHESIVE IN FIE�D. (SENCO GE-24). USE CONSTRUCTION ADHESIVE (AFG01) ON JOISTS RAKE EDGES OF SHINGLE ROOFS (IBC 1507.2.9.3). . <br /> SHEATHING. . . . . . . . . . .7/16" APA RATED (24/16) MINIMUM <br /> BOTTOM PLATE—TO—FLOOR 0.131" x 3" NAILS Q 8"oc (SENCO KC27 OR EQUAL) <br /> ROOF: FRAM�NG . . . . . . . . . . . . .2 x 10 DF #2 RAFTERS Q 24"oc . <br /> SHEATHING—TO—STUD @ SIDEWALL 16 ga. x 1 3/4" STAPI.ES Q 6"oc EDGE, 12"oc FIELD (SENCO N19) RIM—TO—RAFTERS MIN. OF 3— 0.131" x 3" NAILS (SENCO KC27 OR EQUAL) w/ 2" FURRING ON BOTTOM FOR R38 <br /> ALL EDGES SUPPORTED BY FRAMING OR BLOCKING <br /> FURRING—TO—RAFTERS MIN. 4— M20 2 x 3 (MIN.) PLATES EACH SIDE RIDGEBEAM. . . . . . . . . .DOUBLE 1 1/2" x 24" CONTINUOUS LVL 2.OE <br /> SHEATHING—TO—STUD � ENDWALL SEE ENDWALL FASTENING NOTES ON ELEVATIONS. <br /> ROOF RIM—TO—TOP PLATE Q.131" x 3" NAILS � 8"oc (SENCO KC27 OR EQUA�) LEDGERS. . . . . . .. . . . . .2 x 4 D.F. TAPER CUT <br /> LAP SIDING TO STUD PER MANUFACTURES SPECIFICATIONS <br /> LEDGER—TO—RIDGEBEAM 0.131" x 3" NAILS @ 3"oc & 3 � BUTT JOINTS (SENCO KC27 OR EQUAL) RIMS. . . . . . . . . . . . . . . . .2 x 6 CONTINUOUS LVL 2.OE <br /> THREE STUD CORNER CONNECTION 0.131" x 3" NAILS @ 12" (SENCO KC27 OR EQUAL) WITH 2 x 10 DF VENT BLOCKS <br /> RAFTER—TO—RIDGEBEAM 4— 0.131" x 3" NAILS (SENCO KC27 OR EQUAL) <br /> RIDGEBEAM—TO—RIDGEBEAM 4 ROWS � 0.131" x 3" NAII�S Q 12"oc INSULATION. . . . . . . . . .R38 CELLULOSE BLOW—IN OVER CLASS "A" <br /> MATERtAL (AIR BARRIER COMPONENT) <br /> AIR BARRIER NOTES: <br /> SHEATHING—TO—ROOF MEMBERS 16 ga x 13/a" STAPLES � 6"oc EDGE, 12"oc FIELD (SENCO N19} CEILING. . . . . . . . . . . . . .SUSPENDED T—BAR (PER fBC 808.1) <br /> THESE KEY AREAS SHALL BE SEALED BY CAULKING, GASKETS, TAPE OR WEATHER—STRIPPING: NOTE: SHEATHING TO BE INSTALLED PERPENDICULAR TO THE RAFTERS. ` <br /> —JOINTS AROUND FENESTRATION (WINDOWS AND DOOR FRAMES): USE APPROPRIATE�Y SIZED BACKER ROD WITH M4NIMUM OFFSET SHEATHING 4 ft. AND BLOCK EDGES OF ANY PIECES LESS THAN 24" ARCHITECTURA� . . . . .12" OVERHANG <br /> 2" LAP AT ENDS. <br /> —JUNCTIONS BETWEEN WALLS AT: MODLINECONNECTION: NOTE: ALL MODLINES (DEFINED AS THE SPACE BETWEEN ADJOINING MODULES) SOFFIT. . . . . . . . . . . . . . . .FIBER CEMENT PANEL, PERFORATED FOR � <br /> —BUILD�NG CORNERS: USE CAULKING MUST BE INSULATED AT THE ROOF, FLOOR AND WALLS ON SITE. VENTING AS REQUIRED <br /> —STRUCTURAL FLOORS: USE SILL SEAL OR CAULKING <br /> —ROOFS (AT RIM): USE SILL SEAL OR CAULKING RIDGEBEAMS 1/2" BOLTS w/ 1Y2" DIA. WASHERS C�? 6'-0"oc AND 8" FROM EACH END VENTING. . . . . . . . . . . . .SOFFIT AND RIDGE <br /> —PENETRATIONS OF UTlL1TY SERVICES THRU THE AIR BARRIER @ ROOFS, WALLS, AND FLOORS: USE CAULKING, SPRAY <br /> FOAM, OR AIR BARRIER TAPE. (MINIMUM 2" EDGE DISTANCE) <br /> —BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS: USE BACKER ROD, CAULK, SPRAY FOAM OR AtR BARR{ER TAPE. RIM JOISTS 1/2" BOLTS w/ 1Y2" DIA. WASHERS � 4'-0"oc AND 8" FROM EACH END A,�' f c <br /> —JOINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDANTS: USE CAULK OR APPROVED TAPE. (MINIMUM 2" EDGE DISTANCE) �1�� <br /> —RECESSED LIGHTING FIXTURES: USE CAULK OR SPRAY FOAM <br /> SIDING. . . . . . . . . . . . . . .FIBER CEMENT LAP SIDING WITH 8 EXPOSURE <br /> OVER BUILDING WRAP. BUILDING WRAP TO <br /> EXTEND TO BOTTOM OF FLOOR RIM (MIN.) <br /> MOISTURE . . . . . . . . . . .WRAP LOWER 12" OF BUILDING & CORNERS WITH <br /> C B A PROTECTION MOIST—STOP. WRAP BUILDING w/BUILDING WRAP <br /> 4 6 SHEATHING. . . . . . . . . . .Y2" CDX PLYWOOD (MIN.15/32" RATED SHEATHING) <br /> � .� A-4 A-4 FASCIA. . . . . . . . . . . . . .1 x 6 <br /> / <br /> TRIM. . . . . . . . . . . . . . . . .1 x 4 AT CORNERS, WINDOWS, DOORS AND <br /> 1 x 6 � MODLINE <br /> I � �2 3 2 NOTE:2"x 2" GALV. FLASHING UNDER CORNERS <br /> LU26 HANGERS AT ALL RAFTERS �2 A-4 A-4 SHIP LOOSE TO BE INSTALLED ON SITE BY <br /> ,'� OVER DOOR & WINDOW OPENINGS —— ! —` OTHERS <br /> � WITH 6— 0.131" x 1�/�" NAILS � _ FRAMING. . . . . . . . . . . . .2 x 6 D.F. #3 or BETTER STUDS C� 16"oc <br /> � INTO LVL ROOF RIM I RIDGEBEAM BRACING �� / � <br /> '� ,,. � / SEE DETAIL 5 � . , *� � TOP PLATE. . . . . . . . . .2 x 6 CONTINUOUS LVL 2.OE <br /> ' '� \�' � A-4 FLAME SPREAD i� \' BOTTOM PLATE. . . . . .2 x 6 D.F. <br /> i I IS 25 OR LESS � <br /> \ 124" � INSULATION . . . . . . R-21 FIBERGLASS BATTS <br /> i � ' <br /> sEA� — 6 FT. WI E WINDOWS � <br /> AT ROOF , INTERIOR FINISH. . . . . .MATERIAL INSTALLED FROM STUDS OUT <br /> RIM/TOP n� —USE 2— 2x6 D.F. #2 w� MIN. R10 RIGID FILLER — � EXT. WALLS:LAYER 1: 5/8" TYPE 'X' SHEETROCK (AIR BARRIER} <br /> PLATE —USE (2� FULL HEIGHT STUDS AND Q LAYER 2: Yz�� VINYLWRAP TACKBOARD (FINISH) <br /> (1� TRIM STUD AT EA. SIDE OF WINDOW m ABOVE WALL FINISH: LAYER 1: 5/8" SHEETROCK <br /> t� <br /> o AT GABLE ENDS <br /> NICD BACKER � <br /> � ROD . � <br /> I AROUND � o I SKIRTING. . . . . . . . . . . . .SHIP LOOSE <br /> � INTERIOR = <br /> � SIDE OF � � ONE DRY CUP PERM VAPOR GUTTERS . . . . . . . . . . . .PROVIDED AND INSTALLED ON SITE BY OTHERS <br /> ' WINDOWS � BARRIER ON THE WARM 51DE, <br /> � AND DOORS w p � <br /> TYPiCAL THRU—OUT BUILDING. <br /> � p U m <br /> FL00 : <br /> ' i o <br /> � � � i COVERING. . . . . . . . . . . .ON SITE BY OTHERS <br /> CAULK WALL � � <br /> CORNERS FROM � DECKING. . . . . . . . . . . . .23/32�� APA RATED T&G — GLUED AND NAILED <br /> TOP TO BOTTOM �., I (AIR BARRIER COMPONENT) <br /> AT INTERIOR i <br /> � FRAMING. . . . . . . . . . . . .2 x 8 DF #2 JOISTS � 16"oc <br /> SEAL I A-4 RIMS. . . . . . . . . . . . . . . . .2 x 8 CONTINUOUS LVL 2.OE <br /> AT FLOOR � 4 7 NOTE:12" HIGH MOISTURE BARRIER INSTALLED ON <br /> RIM/BOTTOM /��` � A-4 A-4 � � PERIMETER (OVER GYPSUM) AT RIMS AND END <br /> PLATE / � � JOISTS <br /> � , , ' � � '� � I JOIST HANGERS. . . . . .AT ALL RIMS � <br /> � � INSULATION . . . . . . . . . .R-3Q UNFACED FIBERGLASS BATT FIBERGLASS <br /> T \ . <br /> �� �/ � �` �� (USE TWO LAYERS OF R-15) <br /> MIDSPAN MIDSPAN <br /> SUPPORT �" SPACE SUPPORT BOTTOM COVER . . . . . .CLASS A <br /> REQUIRED REQUIRED <br /> 6'—11" 6'—11" 6'—11" 6'—11" 09/27/2017 <br /> 13'-10" 13'-10" �G o wa��Tl�, <br /> � ,�`� .: '�G�� <br /> � R <br /> � <br /> }r <br /> S E C T I O N - A A �°� ��G IS°°ERti� �ww� � <br /> ��Sf�NAL ���5 <br /> 1/2" = 1'-0„ � <br /> 9-7-17 DELETE RIGID FOAM ON INTERIOR OF EXTERIOR WALLS LDG COPYRIGHT 2017, BLAZER INDUSTRIES, INC. � MODULAR Approved for Const: Job No: 19031 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY C/assroom for. <br /> OF BLAZER INDUSTRIES, INC.AND SHALL �� 28 X 32 KC DA - Everett S D File Copy: <br /> NOT BE REPRODUCED, USED,OR DISCLOSED �� INDUSTRIES,INC. � � <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE Drawn By: LDG � <br /> .,� www.blazerind.com �/A. GOLD Pacific Mobile 17 BLMP-04 A9 WA issue Date: 9-7-17 <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� P.O.BOX 489 ■ Aumsville,OR 97325-0489 <br />