My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2003 ADAMS AVE 2018 Plans 2022-12-29
>
Address Records
>
ADAMS AVE
>
2003
>
Plans
>
2003 ADAMS AVE 2018 Plans 2022-12-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2022 9:33:50 AM
Creation date
8/13/2019 10:32:58 AM
Metadata
Fields
Template:
Address Document
Street Name
ADAMS AVE
Street Number
2003
Permit
C1803-013
Year
2018
Notes
NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�___-—_ <br /> - <br /> �L V ����1 V� . <br /> 76'-0�� , <br /> 28'-0° 48'-0" . <br /> 18'-0" 30'-0" <br /> 10'-7" 7'-5�� <br /> 3'-0" 7'-7° <br /> --- ----- --------- - - - --------------------------------- <br /> i 4040 � � i-------------- <br /> � , <br /> ,- -------------------------------------------�- 5 5&P _ j <br /> N � � LA55 - ------i i � � <br /> � r-' I <br /> i ( � I � � � <br /> N i � 50 CFM FAN I J � � c� � <br /> � ATTIC vEtvT ouT � WALK-IN � —' � ` i o� <br /> � � I � O N I� � � �O � � o . <br /> � I ATTTC � I MASTER �n I o � I * <br /> � ACCE55 i � BATH �NT OUT N j N � - � � <br /> � 2640 , , � � � I � � i <br /> � � � � i i � N — ------J � cr� N I <br /> ii � <br /> ,� �`'� � d' ln i i I 2468 S&P � � � �� <br /> �' �� � � N � ;� j 4'-5 1/2" '-6' 4'-7 1/Z" 3�_ �� 4'-2" � � j � w Q �I <br /> �n d' � � a , � - <br /> �- � <br /> � = I O W � ��bb� I bb� �bb � � f � � � I M - <br /> � � <br /> IM T----------- � � <br /> 0 0 � � � � _� w UNFINISHED --�+____T���--�--__=fi== ----------------- �� ----- " ------ -------------------------------- �---- `r� � <br /> v � �' � <br /> c� N ,.,., � `'r' � ---------- � O---STORA6E ROOM � � ��., ; � � �n`s I � � p O� oj _ ° ;, <br /> � � � <br /> � m �� � ; ; y � d- � DN � � � � � I ``�' , <br /> � �� V Q � � OPTIONAL I `v � � � � OPEN TO BELOW v a p� m /''� <br /> = � � ► C�J I � �...f... �� <br /> � � � �„ � � WALK-IN `� � I I �n � , <br /> � ; � a Q � � CLOSET � � o � � � � a o <br /> � rn � a a ; ; LOCATION j .�. � � � �� � j � � M�VIANUF'� TRUSSES @ 4" O.0 <br /> MAS ER Z �� ^/ H <br /> W � � i i � ' ' � � � OI `��iL� <br /> > d- 1 � '-' � � � BEDROOM � nc � �,� � r.., <br /> � 2640 � q ; �i i � � � �ISPLAY APPROVED ST MPS <br /> I � A TTIC _ <br /> - � ACCE55 � � � >, ° � � I � � I o. <br /> \ � ( I = J q i I � ( ' <br /> .-, � ( Z cL � � � I O . <br /> � � ATTTC Q H � �-- ------ � . <br /> I � � Q L ---------� j , <br /> � � ( � � I � � <br /> - ' I ' ' � <br /> I � � <br /> o � � <br /> , I <br /> NL ----------------------------------�— ------I— EGRE55 i <br /> � 30 50 3� 50 30 50 I __________ � � <br /> - �— -- -�- — ----- — --� -- -- -- —1------------------------------------- � <br /> , „ � �� � �� � �� � �� <br /> (Z:�� �(��U��T�_���l _ _.__ _ 5 -6 3 -3 1/2 5 -0 1/Z 2 -1 2 -1 <br /> av .� L�. N R� tZM � <br /> � � p�� 3 G(�OS�� _ 13'-10" 4'-2" <br /> � , <br /> 18'-0" 30'-0" � � <br /> 28'-0° 48'-0° <br /> 76'-0" <br /> _ <br /> P R R P A � <br /> UP 40 <br /> scA�E 1�4�� = i� - o�� ATTIC VENTILATION CALCULATIONS <br /> 1536 S.F. / 150 = 10.25 S.F. NET CLEAR AREA REQ'� <br /> 14" X 7" VENT = .51 SQ. FT. NET CLEAR VENT AREA <br /> 10.25 SF (REQ'D AREA� _ 20 VENTS REQ'D <br /> ,51 S.F. (ACTUAL AREA) TRUSS NOTES <br /> 18'-0" 18 -0 MANUFACTURED TRUSSES TO BE OESIGNED AN� DRAWINGS PREPARED ; <br /> � �� BY A LICENSED WA STATE STRUCTURAL ENGINEER. <br /> • 10'-7° 7'-5° 10'-7" 3'-8 1/2" 3'-8 1/2" DRA WTNGS TO BE ON SITE AND AVAILA BLE TO THE INSPECTOR AT � <br /> SAFETY THE TIME OF INSPECTION. . � <br /> GLA55 A A G40 40 A A 20 30 TRUSSES SHALL NOT BE FIEL� MO�IFIED WITHOUT PRIOR APPROVAL Q �/ <br /> BY THE BUILDING OFFICIAL t.�, I�..�L. <br /> 5&P _ 5o cFM FAN `" ALL BRACING SPECIFIED BY THE TRU55 MANUFACTURER SHALL BE W �� <br /> � V <br /> SOAKING -------, � SOAKING VENT OUT � � INSTALLE� ACCORDING TO THE SUPPLIED ENGINEERIN� �RAWINGS. Z <br /> � .-� TUB � <br /> TUB i o z4bs M _ GARAGE ROOF TO BE 12:12 PITCH � <br /> —► is� - 50 CFM FAN c� H � ' <br /> 50 CFM FAN � � —.t � VENT OUT � Q ��., W <br /> VENT OUT � 1NALK-IN � Q � � � <br /> �F N CLOSET � :o '�' O � � u? '� TRUSSES TO BE PERMANENTLY LABELE� TO SHOW MANUFACTURER, � <br /> MASTER � ' o i N � � DESIGN LOAbS, AN� ON CENTER SPACING. w <br /> BATH 0 CFM FAN I �" MASTER <br /> � NT OUT I - BATH � DETAILS CALCULATIONS AND PROFTLE DRAWIN65 TO BE ON SITE AT � � <br /> N � ------' m � z tv c osET ---� `" THE TIME OF INSPECTION. c�.. <br /> � L NE L _ <br /> 5&P III 5&P �, , � <br /> 2468 24bs APPROVED HANGERS TQ BE USED AT ALL TRU55 TO TRU55 CONNECT 5. � .. <br /> BOTTOM CHORDS OF TRUSSES TO BE HELD OFF OF NONBEARING <br /> , ,� ,_ � , „ , „ INTERIOR WALLS WITH "SIMPSON STC ROOF TRU55 CLIP" OR EQUAL. ___ <br /> 5'-11 1/2" '-6' 4'-7 1/Z" 1'-9" 4'-2° 5 -11 1/2 6 6 -4 1/2 4 -2 � <br /> GABLE END TRUSSES TO HAVE VERTTCAI. MEMBERS AT 24" O.C. TO ��I� � � <br /> 18'-0° 18'-0" RECEIVE SIDIN6. <br /> GABLE TRUSSES TO BE �ESTGNED FOR LATERAL LOADS OR INSTALL <br /> 1 x 4 DIA60NAL BRACTNG FROM RIDGE TO TOP PLATE. <br /> INSTALL 2 x 6 STRONGBACK ON TOP OF BOTTOM CHORD AT MIDSPAN <br /> T �� (OR AT 1/3 POINTS FOR SPANS GREATER THAN 28'-0"). <br /> T AST R A � � <br /> A T #�1 A � ������ <br /> T A T R . ���� �� <br /> A N� S <br /> . <br /> ��������� ��� ������ <br />
The URL can be used to link to this page
Your browser does not support the video tag.