My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2018 BLDG 40-05 Plans 2022-12-06
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-05
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-05 Plans 2022-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 2:54:11 PM
Creation date
8/13/2019 10:59:27 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-05
Permit
B1803-014
Year
2018
Notes
BLDG MODIFICATION FOUNDATION FOR PALLETIZED RACEWAY TOOL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � . � � . . � � ...''�. <br /> INCLUDED INCLUDED INCLUDED I SS U E LEG EN D <br /> IN SET SHEET IN SET SHEET IN SET SHEET <br /> DRAWING N0. N0. DRAWING TITLE REV DATE DRAWING N0. N0. DRAWING TITLE REV DATE DRAWING N0. N0. DRAWING TITLE REV DATE NOT YET ISSUED <br /> G E�1 ERAL M EC HAf� I CA� E�ECTR CA� � $ T <br /> Q PR�VIOUSLY ISSUED, <br /> � 40-005—GO GO COVER SHEET — 03.05.18 � 40-005—M1a M1a SCHEDULES C 03.Q5.18 � 40-005—EO EO ELECTRICAL LEGEND C 03.05.18 NOT W THIS ISSUE , <br /> � 40-005—G1 G1 INDEX OF DRAWINGS — 03.05.18 � 40-005—M1b M1b PIPING LEGEND B 03.05.18 � IN THIS ISSUE <br /> � 40-005—M1c M1c SCHEDULES B 03.05.18 � 40-005-1E62R 1E62R PARTIAL 208Y/120V POWER PLAN — REMOVAL C 03.05,18 <br /> � 40-005—M1 M67R M1 M67R PARTIAL HVAC PIPING PLAN — REMOVAL B 03.05.18 � 40-005—E2 E2 480Y/277V POWER PLAN — FIRST FLOOR FRO 03.05.18 M <br /> � 40-005—TM62R TM62R PARTIAL HVAC PIPING PLAN — REMOVAL B 03.05.18 � 40-005—E2a E2a MOTOR CONTROL CENTER B 03.05.18 PREL PRELIMINARY ISSUE <br /> C IUI � � 40-005—UGM112R UGM112R PARTIAL PLUMBING PLAN — REMOVAL B 03.05.18 � 40-005—E4 E4 SUBSTATION #1-6 (V05-1) ONE LINE DIAGRAM FRO 03.05.18 FOR REVIEW OR <br /> � 40—YD—C2 C2 GENERAL CIVIL NOTES — 03.05.18 � 40-005—UGM116R UGM116R PARTIAL PLUMBING PLAN — REMOVAL B 03,05.18 � 40-005—E4a E4a SUBSTATION #1-7 (V05-2) ONE LINE DIAGRAM D 03.05.18 INFORMATION ONLY : x� T <br /> � 40-005-1M112R 1M112R PARTIAL PLUMBING PLAN — REMOVAL B 03.05.18 � 40-005—E9 E9 GROUNDING PLAN C 03.05.18 NOT FOR CONSTRUCTION <br /> � 40—YD—C80T C80T COMPOSITE SITE PLAN — 03.05.18 � 40-005-1M116R 1M116R PARTIAL P�UMBING PLAN — REMOVAL B 03.05.18 � 40-005—TE12 TE12 PARTIAL LIGHTING PLAN B 03.05.18 a <br /> � 40—fl05—TM112R TM112R PARTIAL PLUMBING PLAN — REMOVAL B 03.05.18 � 40-005-1E61 1E61 PARTIAL 208Y/120V POWER PLAN FRO 03.Q5.18 ORIG OR{GINAL ISSUE <br /> � 40—YD—C220-32TR C220-32TR ENLARGED PLAN — REMOVAL — 03.05.18 � 40-005—TM116R TM116R PARTIAL PLUMBING PLAN — REMOVAL B 03.05.18 � 40-005-1 E62 1 E62 PARTIAL 208Y/120V POWER PLAN C 03.05.18 FOR PERMIT, BID, <br /> � 40-005—RFM116R RFM116R PARTIAL PLUMBING PLAN — REMOVAL B 03.05.18 � 40-005-1 E65 1 E65 PARTIAL 208Y/120V POWER PLAN FRO 03.05.18 PROCUREMENT OR <br /> � 40—YD—C220-32T C220-32T ENLARGED PLAN — GRADING AND PAVING — 03.05.18 � 40-005-M3R M3R DIAGRAMS — REMOVAL C 03.05.18 � 40-005-1 E66 1 E66 PARTIAL 1 ST FLOOR 208Y/120V POWER PLAN K 03.05.18 <br /> � 40—YD—0532-1 C532-1 CIVIL SECTIONS AND DETAILS — 03.05.18 � 40-005—M456R M456R SECTIONS & DETAILS C 03.05.18 � 40-005-1 E111 1 E111 PARTIAL 480Y/277 VOLT POWER PLAN FRO 03.05.18 <br /> � 40-005-1 E112 1 E112 PARTIAL 277/480V POWER PLAN E 03.05.18 A DRAWING REVISION — <br /> � 40-005—TM12 TM12 PARITAL HVAC PLAN B 03.05.18 � 40-005-1 E115 1 E115 480Y/277 VOLT POWER FRO 03.05.18 SEE SPECIFIC DRAWING <br /> ' � , <br /> � 40-005—M1 M67 M1 M67 PARITAL HVAC PLAN B 03.05.18 � 40-005-1 E116 1 E116 PARTIAL 277/480V POWER PLAN E 03.05.18 FOR NATURE OF <br /> A R C H I T E C T U RA� � 40-005-TM62 TM62 PARTIAL HVAC PIPING PLAN B 03.05.18 � 40-005-M 1 E116 M 1 E116 PARTIAL 277/480V POWER PLAN C 03.05.18 +y <br /> � 40-005-TM66 TM66 PARTIA� HVAC PIPING PLAN B 03.05,18 <br /> � 40-005-1Al2R 1Al2R PARTIAL FLOOR PLAN — REMOVAL C 03.05.18 � 40-005—UGM112 UGM112 PARTIAL PLUMBING PLAN B 03.05.18 FRO FOR REFERENCE ONLY — <br /> � 40-005—UGM116 UGM116 PARTIAL PLUMBING PLAN B 03.05.18 DRAWWG OF RECORD INCUDED . <br /> � � 40-005-1Al2 1Al2 PARTIAL FLOOR PIAN C 03.05.18 � 40-005-1M112 1M112 PARTIAL PLUMBING PLAN B 03.05.18 TO PROVIDE ADDITIONAL <br /> � 40-005-1A15 1A15 PARTIAL FLOOR PLAN D 03.05.18 � 40-005-1M116 1M116 PARTIAL PLUMBING PLAN B 03.05.18 <br /> � 40-005-1A16 1A16 PARTIAL FLOOR PLAN C 03.05.18 � 40-005—TM112 TM112 PARTIAL PLUMBING PLAN B 03.05.18 T TEMPORARY DRAWING — <br /> � 40-005—A350 A350 DOOR SCHEDULE ORIG 03.05.18 � 40-005-TM116 TM116 PARTIAL PLUMBING PLAN B 03.05.18 DRAWING CREATED FOR CURRENT <br /> � 40-005—A501 A501 FENCING DETAILS B 03.05.18 � 40-005—RFM112 RFM112 PARTIAL PLUMBING PLAN B 03.05.18 CONSTRUCTION PROJECT ONLY <br /> � 40-005—A502 A502 MISCELLANEOUS DETAILS ORIG 03.05.18 � 40-005—TM262 TM262 PARTIAL FIRE PROTECTION PLAN B 03.05.18 NOT A BOEING ROCORD DRAWING <br /> � 40-005—TM266 TM266 PARTIAL FIRE PROTECTION PLAN B 03.05.18 " <br /> � 40-005—M3 M3 DIAGRAMS C 03.05.18 <br /> � 40-005—M456 M456 SECTIONS AND DETAILS C 03.05.18 <br /> � 40-045—M504 M504 SECTIONS AND DETAILS FRO — <br /> � 40-005—M510 M510 SECTIONS AND DETAILS FRO _ <br /> � 40-005—M512 M512 SECTIONS AND DETAILS FRO — <br /> ,�-.. <br /> STR U CTU RA� <br /> � 40-005—S2A-1 S2A-1 STRUCTURAL ABBREVIATIONS AND NOTES ORIG 03.05.18 " <br /> � 40-005—S2A-2 S2A-2 STRUCTURAL NOTES ORIG 03.05.18 <br /> � 40-005—S2A-3 S2A-3 STRUCTURAL NOTES ORIG 03.05.18 <br /> � 40-005—S62R S62R PARTIAL FLOOR SLAB PLAN — REMOVAL � B 03.05.18 <br /> � 40-005—S66R S66R PARTIAL FLOOR SLAB PLAN — REMOVAL B 03.05.18 <br /> � 40-005-1 S62R 1 S62R PARTIAL FLOOR FRAMING PLAN — REMOVAL B 03.05.18 : <br /> � 40-005—S210R S210R FRAMING ELEVATIONS — REMOVAL ORIG 03.05.18 <br /> � 40-005—S12 S12 PARTIAL FOUNDATION PLAN B 03.05.18 � <br /> � 40-005—S16 S16 PARTIAL FOUNDATION PLAN B 03.05.18 <br /> � 40-005—S62 S62 PARTIAL FLOOR SLAB PLAN B 03.05.18 <br /> � 40-005—S66 S66 PARTIAL FLOOR SLAB PLAN 6 03.05.18 <br /> - � 40-005-1 S62 1 S62 PARTIAL FLOOR FRAMING PLAN B 03.05.18 <br /> � 40-005—S210 S210 FRAMING ELEVATIONS ORIG 03.05.18 ' . <br /> � 40-005—S506 S506 STRUCTURAL bETAiLS ORIG 03.05.18 z <br /> � 40-005—S506-1 S506-1 STRUCTURAL DETAILS ORIG 03.05.18 <br /> COFFMAN . <br /> N � � H E E R S ISSUE FOR PERMIT n � <br /> 1101 2nd Avenue,Suite 400�Seattle,WA 98101 ,��. <br /> ph 206.623.0717�fax 206.624.3775 � <br /> coffman.com <br /> r( <br /> LASTING creativify�resWts�relationships r ' <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ,j s, DRAWN DATE SUBTITLE CURRENT REVISION SYMBO� � DATE � <br /> ��og *��0,� ACCEPTABILITY HEBOEI�LKOV 03.05.18 INDEX OF DRAWII�GS W5240458 03.05.� 8 � <br /> — 777X PALLETIZED RACEWAY TOOLS W4975102 CEI ESO 03.05.18 �R,6 „� THIS DESIGN AND/OR R. MORGAN 03.05.18 sHEET c <br /> � �e o SPECIFICATION IS APPROVED ENGINEE TITLE 777X PALLETIZED RACEWAY TOOLS <br /> BOE,�� AP RQVED BY DEPT. DATE E. OJALA 03.05.18 � t <br /> CHECKED 1 c <br /> � 39631 wa APPROVED BU I LDI NG �O�oo� JOB N0. W524O45H COMP N0. C <br /> � R�L °` � <br /> ��j�NAL �'�� APPROVED ARCHITECTURAL MASTER EVERETT, Wq °wc No. 40-005—G1 <br /> 3/511 R <br />
The URL can be used to link to this page
Your browser does not support the video tag.