My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2410 38TH ST 2019-08-22
>
Address Records
>
38TH ST
>
2410
>
2410 38TH ST 2019-08-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2019 11:23:04 AM
Creation date
8/13/2019 11:14:34 AM
Metadata
Fields
Template:
Address Document
Street Name
38TH ST
Street Number
2410
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
412 <br /> March, 15th, 2019 <br /> To: James Bronder, P.E., S.E. <br /> Associate Engineer <br /> Plans Examiner <br /> City of Everett <br /> Correction Letter <br /> RE: Building Permit Review Letter <br /> Dear Mr. Bronder, <br /> In response to the Plan review comments, the plans have been examined and revised per your <br /> comments in order to receive approval for a building permit. Please see the response to your <br /> comments below. <br /> Architectural 1. <br /> City Comment: <br /> 1. On Sheet A1.1, the proposed cooler box appears to increase the fire area of the existing <br /> building. Previous records appear to indicate that the existing structure is a nonsprinkler'd, Type <br /> 5B structure with a B Occupancy. Per IBC 2015 506.2, the total area of proposed area and <br /> existing area appears to exceed the allowable area threshold of a nonsprinkler'd building. <br /> Please provide details indicating a proposed sprinkler system is to be installed or indicate via <br /> details an alternate means of providing fire separation between the two areas. <br /> Answer: <br /> The 2-hr fire separation between the existing warehouse facility and the new cooler box is <br /> accomplished by the existing 8" thick cmu exterior wall of the warehouse. To protect the <br /> existing opening, we are replacing the existing roll up door with a minimum 90 minute rated <br /> roll up door with a fusible link to release and close the roll up door if fire is present. <br /> Please reach out to me with and questions in regard to the proposed corrections. I have also included <br /> information on the proposed roll up door to be installed as well as the shop drawing and installation <br /> pack for premanufactured cooler box deferred submittal for your review and approval. <br /> Sincerely, <br /> Matt Schreifels <br /> matts(c�2812architecture.com <br /> 2812 Colby Ave Everett, WA 98201 <br /> 2812 Colby Avenue Everett WA 98201 <br /> P (425)252-2153 www.2812architecture.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.