Laserfiche WebLink
� � . . ... . . . � � . <br /> .'� � � � � � 1 • . <br /> ��� � (E)�3SC 45KVA (E)MCC-H3A � � • � '4 <br /> T � <br /> __��.___ � �__�.. � __I , � ����-���v . <br /> -- - ----�---- - � �--- G E N E RAL N OTES 4 <br /> �., ___ __.______.__ ___..._..__ _ —_�_�_ �. 3 � 1011 SW Klickitat Way, Suite 208 <br /> ��� I <br /> i� � �,���E� � 1. CIRCUIT NUMBERS SHOWN REFER TO PANEL L2SE UNLESS OTHERWISE NOTED. Seattle,WA 98134 <br /> � ��. V�� �_-�� { � 2, PROVIDE ALL CONDUIT, BOXES AND WIRE AS REQUIRED BY WAC, NEC AND P: ZO6.631.8442 � www.oaips.COCTI <br /> � � F L3SC-20,22 � � SPECIFICATIONS. <br /> �3 � �� 1 � � 3, PROVIDE ALL CONDUIT, BOXES AND WIRE AS REQUIRED BY WAC, NEC, AND SPECIFICATIONS <br /> � � SECTIONS 26 0510, 26 0511, 26 0519, 26 0532 AND 26 0533 FOR A FULLY FUNCTIONING ` <br /> (I�--, ,- _.v____. ______� �.�-�, ( � SYSTEM. <br /> _�� _ � <br /> � ir� `���--�-- i��v � I�`��� F � �'���-~-�� � � � 4, WALL MOUNTED DEVICES SHALL NOT BE MOUNTED BACK TO BACK UNLESS PHYSICAL SPACE - <br /> � s L3SC-22 � --,___ � ` _ ���`� NECESSITATES IT. IF THESE DEVICES MUST BE MOUNTED BACK TO BACK, PROVIDE SOUND <br /> t; , r- L3SC-20� <br /> � ��� � �� � ;� � I �� � � INSULATION AT BOXES. � � � 1 , <br /> � -_ / I � I 5. FOR BRANCH CIRCUITS TNAT EXCEED 75 FEET IN LENGTH, INCREASE WIRE BY ONE WIRE SIZE. �'_l I E N G I N E E R I N G <br /> - -- –— :� , <br /> F� � � � � �� � <br /> 6� �—__ �� 21 � , �L +3�6 3 6, HOMERUNS SHALL NOT BE COMBINED. <br /> � � � Consulting Electrical Engineers <br /> 6 I ; 4 � 7. PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. <br /> I � 3 / � � � �� , <br /> I i - % �'� � 8. FOR LOAD CHANGES, REFER TO (AFiER) PANEL SCHEDULES. 19515 North Creek Parkway, Suite 302 <br /> � � �`� �� � � Bothell, Washington 98011 <br /> . � ( ��_ __�� � S �_� . <br /> l� __ <br /> i J -S — � -- � -� --�—,--- --r Phone: 425-402-9400 Fax: 425-402-9402 <br /> . . � � J �� �� � - J _�_�� � i � . . . <br /> � V i � ��_���_� �� . <br /> , �� , ���--�� � �; _ I � � <br /> � i , � � _ � <br /> ; . � � <br /> i ( �L �SA-�13 --� � � � ; � <br /> � r=--i-,�_ � --- � ; � <br /> 2 I+3�,, _� ��-- � r-- �--^—� � - ; � � � �V �,�`+,L ,� � <br /> � � � ;, ,. �,.�:� � - . <br /> � ' � � <br /> � � �� <br /> / �-� s I ---� � <br /> . _ ___ .. <br /> G \ _ .. _. ._ . <br /> � , �� , / ��� I ( o �JJ � `__ ��t..-�_ ���' � .' <br /> � ��� -=%� � -__ ; ! ��—__� == � -;�_ ���--__–�__.�---_ � F LAG N OTES � � �� , <br /> � ---R____�� ; j � - —�===��i � I _ � <br /> -- - , � ,�-� �j . - ��____a.�__� -_ .�-.� . <br /> � �---�� IL �1-� � �� 1 PROVIDE CONNECTION TO DYSON DB HAND DRYER AS SHOWN. 120V/1440W. ZO'I7 <br /> � i� ��� �� � � ���� -�. � � ��� �� � COORDINATE WITH GENERAL CONTRACTOR ANY ALTERATIONS TO GWB CEILING TO x73 �� ' <br /> �' "�-�� � �� �\ � � � � � MAKE LOCATIONS SHOWN WORK. � I � <br /> / t �NAL � � <br /> j � � � � � �� � � � � � � C R�U�I�T�THE RECEPTACLES 0 �X�ISTING RECEP�ACLE��C R U�IT�SEE F LAG� NOTE�, � <br /> �� � � � �(� ; � ` � ' DETAIL 2, SHEEf ED2.1. <br /> �-= _tL..�_,_._._._. � f�_._! , _.1L. � �� �`____......._� ..�,�_ � ....�..t�.�,�.,.,.,�i,.���....�,.��� , <br /> ..`.._ � -----------�------ �M�`��'�"�� ��_ 3 RE-INSTALL EXISTING FIRE ALARM DEVICE IN EXISTING ROUGH-IN AND <br /> �-,:�_���_��_,� ___�__ �.. __��. ��.�_.__.�__._m.__._� � � RE-CONNECT EXISTING FIRE ALARM CIRCUIT TO EXISTING DEVICE. PROVIDE LABOR <br /> �_ <br /> � � � AND MATERIAL AS REQUIRED TO ENSURE A PROPERLY WORKWG SYSTEM. SEE <br /> �� � � �� � FLAG NOTE 1, DETAIL 2, SHEET ED2.1 FOR ADDITIONAL INFORMATION. <br /> � � �j ��:, <br /> � � ( � PROVIDE LABOR AND MATERIALS AS REQUIRED TO INTERCEPT AND EXTEND <br /> � , � � EXISTING FIRE ALARM ROUGH-IN AND CIRCUIT TO NEW LOCATION SHOWN. '� , <br /> � I � � RE INSTALL EXISTING FIRE ALARM DEVICE IN NEW LOCATION. PROVIDE LABOR AND <br /> � � MATERIAL AS REQUIRED TO ENSURE A PROPERLY WORKING SYSTEM. SEE FLAG <br /> NOTE 1, DETAIL 2, SHEET ED2.1 FOR ADDITIONAL INFORMATION. <br /> PARTIAL 3 <br /> RD FLOOR RESTROOM POWER PLAN � . <br /> 2 SCALE: 1/4" = 1'-0" � <br /> J � <br /> `�, ' � i ' � �' � 0 O <br /> � ��_ ________� _� �. __.LL ___--____�_�_�j�_�w�_�_..�._�.� � � � .�_.�� V � <br /> �---- � So 2 � -r�-- G EN ERAL N OTES <br /> � �` � � <br /> � �.___Y__ > � o , <br /> � F2 �;V�i�ilEi�l F2 = 0 � p�j <br /> � � v� � 3 � � 4 1, CIRCUIT NUMBERS SHOWN REFER TO PANEL H2LA UNLESS OTHERWISE NOTED. z � <br /> � � �- H3 - H3LA-1 2, REFER TO LIGHTWG FIXTURE SCHEDULE, THIS SHEET, FOR ADDITIONAL INFORMATION. Z w W Q � <br /> i � � 3, PROVIDE ALL CONDUIT, BOXES AND WIRE AS REQUIRED BY WAC, NEC, AND SPECIFICATIONS = � � � <br /> �- � �� � � $ SECTIONS 26 0510, 26 0511, 26 0519, 26 0532 AND 26 0533 FOR A FULLY � � O � <br /> !i� -� ��E� l FUNCTIONING SYSTEM. � <br /> --,e_ _��, <br /> i ��� 1�---------��r-�---� ` ,- _--"�---r--'--���-- � � ! �______� q.. WALL MOUNTED DEVICES SHALL NOT BE MOUNTED BACK TO BACK UNLESS PHYSICAL � 0 0 � <br /> '� � , __ � � � SPACE NECESSITATES IT. IF THESE DEVICES MUST BE MOUNTED BACK TO BACK, PROVIDE O <br /> � SOUND INSULATION AT BOXES. � N W <br /> ��� � �' � I � � V � <br /> r - F1 � F1� .-:= ' F1 5. FOR BRANCH CIRCUITS THAT EXCEED 75 FEET IN LENGTH, INCREASE WIRE BY ONE WIRE <br /> H3LA-3 ,H3LA-3 (� , H3LA-3 F 3 SIZE, � J <br /> _ ,r- <br /> I . �� __�- - --- � H3LA- � � 6. HOMERUNS SHALL NOT BE COMBINED. � <br /> �-f= � � _ -- � ; ! ~ <br /> � � 7. PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. W O <br /> / � ) � � <br /> � � j \, _ ___ � � � 8. FOR LOAD CHANGES, REFER TO (AFTER) PANEL SCHEDULES. � , <br /> IG_ i �'— - --- � � _� ��____.� __ <br /> r ! <br /> 1 � � _-_ ����. � w�� �.. ..� �-..� . <br /> �- � � I I ---�����•-��;��.e W . <br /> 4, <br /> � � � <br /> , 1�� ��� 1�� o �-T 11 F9 �� ' � � � � � � <br /> _� --- H3LA-3 � <br /> �-� j �� �--- ( 1=J� _ _ � � � � <br /> I � - - <br /> � �� -� ���� � � <br /> ; �-----� ...�..�,� � <br /> --r��:r- �—� <br /> � � _, <br /> I � I ���� � o� i�l � � � _ � <br /> � , �� � ��� .. . �,_.�...� <br /> - <br /> _. ._� <br /> � � F, F�1� ;—_ � __F?� � _ � �FLAG NOTES <br /> � � L _ H3lA-3 �H3tA-3 � ��H3LA-3�� F1 � i ___�__ <br /> �� � H3LA-3 � ! <br /> � � � - (�_— _�- � �__ '�-� �%- . <br /> � � � j� � ��������-�-�---�--=-- � PROVIDE NEW FIXTURES AS INDICATED. INSTALL IN CEILING OPENWG. COORDINATE <br /> � �� -"� I� ' � , � ! I � I � WITH GENERAL CONTRACTOR ANY ALTERATIONS TO GWB CEILING TO MAKE <br /> �-� `\ \ �__ � �' __ .,` �� \ I ' � LOCATIONS SHOWN WORK. INTERCEPT AND EXTEND EXISTING BRANCH CIRCUIT , <br /> � / <br /> i <br /> - � <br /> � - <br /> � _( � � WIRING. PROVIDE ALL MATERIALS, EQUIPMENT & LABOR AS REQUIRED TO ADJUST <br /> % :� � OPENING AND RE-CONNECT EXISTING EXISTING BRANCH CIRCUIT WIRING TO <br /> � / � \ � � ACCOMMODATE NEW FIXTURE. , <br /> 1 � --� � � � I <br /> I <br /> i <br /> � — � I 3 2 PROVIDE BOXES, CONDUIT AND WIRE AS REQUIRED TO RELOCATE LIGHT SWITCH TO <br /> � '--- - _� -----_-� --- �-�- --i � -----�-----�------�� -----�------�- ---- --�-------1--°° _�__m._�-� ��.""�`�v�_ ` __ ____ _ ._`_ � LOCATION SHOWN. SEE FLAG NOTE 2, DEi'AIL 1, SHEET ED2.1 FOR ADDITIONAL I i I <br /> �� �`�m��__ __..��_. _._ .�_�__. __�_ _._ _ __�.��� INFORMATION. ,� I <br /> ��,._._..�___�_�_�.�..___.______ <br /> � �3 } PROVIDE NEW FIXTURE INDICATED. COORDINATE WITH GENERAL CONTRACTOR FOR —I _ I _ <br /> _---� (� <br /> �-�-- �-- V NEW OPENING IN EXISTING GWB CEILING. PROVIDE ALL MATERIAL, EQUIPMENT & � <br /> � ! � ; LABOR AS REQUIRED TO CONNECT NEW FIXTURE TO EXTENDED EXISTWG BRANCH I i i <br /> � ' CIRCUIT WIRING. � <br /> I ` ' � ' <br /> � � � j � AL�ERATIONS TO XGWBE CEILING TO MAOORd CA7 0 SIT SHOWN WORK� PROVIDER ANY <br /> 1 <br /> � <br /> � � � � , C O N D U I T A N D W I R E A S R E Q U I R E D T O C O N N E C T 7 0 E X I S T I N G C O N T R O L L E D HALL WAY � I � <br /> CIRCUIT. -� -.- <br /> �rn�o�r�2� � �� I , <br /> ,..._�...-.��_� �-�.>...�,u..tis—��. <br /> rr�+r���ec�`� ii I � <br /> PARTIAL 3 RD FLOOR RESTROOM LIG HTI NG PLAN ���� :. �.�_�.��, �� __:�.� � _ ���� .��_�_ � � � <br /> . <br /> 1 . „ _ ,_ » =:�"` %'�, ;� -���.:,���...����.���,�������.� ; ,' o � � <br /> �-_=-_ �' I � <br /> --_. �==G,� � <br /> � � <br /> SCALE. 1/4 - 1 0 <br /> ,� , , �. m �` -0�. � ��,�. , j .Q <br /> � �, r '� <br /> �� � � <br /> � ; — .�.. <br /> � , - : _ <br /> � � . <br /> �� � ��" � � �-�' ' <br /> � � <br /> � � � � " _�-- ��� ��' �� � � I � <br /> ; <br /> � _ �._,�.� __.. -� ; <br /> i <br /> . !" � � � cn <br /> �� � � � - ��3 3 � � � ' ( I <br /> � <br /> _ <br /> � ��� L <br /> - � .�� � <br /> � � <br /> ���� ��� � � R�i� _�. p -- - - - - � <br /> I �—I a <br /> ! �`��-�' �," , � t,�,,� ��- �.�, �, �_-�� � t .� -r <br /> �1����� ���fi��� s�������� �` � � ��x''��„�°��� ,._,��-- _�-a � -�� i .� I � <br /> � ��' .._. � � �,�'�,� � t��' '`` : � N ( m � ".. <br /> .7 � � ;� ! 11 � I � � <br /> TYPE �ESCRI('�l�N �9�n€afac��srer E�A�t3F�C���ER LAt�[P �#LL��TC I�V�'�T RE!'�IARKS �. _ I�� � �!, �� .±�: � � � ; � � <br /> .:.;::.... . . :..: .... . .:, . . ....: :.. ........: ......... ...........,.. :. ...... .. ...... :.. ....... ......... , ........ ,, , �� s 3;, ,��� �o � � — --�— - — � � ° <br /> a� 3 � �y�;i, �y � {� � T r�� a '��._.� . �� i l 1 ���p��y-� �� I <br /> NAiME �ATALt7GN[3. LUMENIS; TYPE ; 4Ei F��I�E� �VATTS =������� .�� �'. -� ,,,�,-� ; ;� �I���� <br /> i �� i,lll; � �I, t �jt ; � ..�� �..�� ':�4�_�. ,,�i. 3 .i.l I'il � 1 ��� � � � � � U <br /> � � '. ��.! . '���,�,'�x��.. �_� �l�_ .�����.� � <br /> Ft R_C��vE� L��'1,?t�'FL'C3iIR�ja"t�'C�H �}lP�1P.lit�1G �'�iLllftl@4'� L�_R-3°�-L�fiJ-G€a1-G-=��'-1i ;�3�3 LEa? �50� �!t,1�,litl� a� � ! <br /> uz �d.�.�-.,,� .��. , <br /> � � � � � � � � � � � � � � � � ; Sheet No / Title: <br /> � �� � ' ' �� <br /> F2 P.ECES�E�t��J� S�Uj;P.E ��Tt�PtL}t�H� �UhdCl �����=15Lf�1-'�K` �"-fa1�J�7L3�ERIRE� 9��}�J LE� 3�C?G �IP91P,ilhJ� 20:7 i! ; � � PARTIAL 3RD <br /> �._�__W��.� - _.._ � f ____��._____�..._ _ ______.__t` <br /> FLOOR PLAN <br /> 'I. �,LL FltlISHEv�� 8E�.+'cRIFiEi� B'°�`,�.R�N(��C�PRlO���Ok2��f2. ` <br /> ' <br /> 2.;=tLL�IC1L�n:�E���a 8E:�ERIFI�C�C�n'��FlTRAG�'t�R PP.ItJR�tJ G1RC}�� ; ' <br /> � � <br /> ��=-_=__ __ __.� -- ._� � <br /> NORTH <br /> KEY PLAN /� , . <br /> NOT TO SCALE � <br /> Project#; XXX <br /> • w����w�«w�����• •����i � <br /> . . .. . . _ _ __. _ :�I'. <br />