Laserfiche WebLink
GENERAL YES NO <br /> Bathroom doors are easily and quickly openable from the outside when locked [rl0 <br /> Carbon Monoxide alarms are installed as required in R315.1 on each level of the home. Er-0 <br /> Smoke alarms are installed on all levels of the dwelling,in each resident sleeping room,outside each separate <br /> sleeping area in the immediate vicinity of sleeping rooms(R314). Er—E] <br /> Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all _ 0 <br /> parts of the dwelling upon activation of a single device. <br /> Access road and water supply meet local fire jurisdictional requirements. Er 0 <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand .�/ <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). L7 0 <br /> Pocket doors shall have graspable hardware available when in the closed or open position. 0'--0 <br /> R311.8 Ramps YES NO <br /> Inside Ramp N/A 0 0 <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) 0 0 <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes <br /> directions. 0 0 <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. 0 0 <br /> Outside Ramp N/A 0 YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) D 0 <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp changes 121"" 0 <br /> directions. <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. 0 <br /> Guards below are depicted vertically as an example only.All Ramps must have Guards OM— ,---- 0 0 <br /> -y L— Less than 4" Handrail-3both sides <br /> ■ ■i■ j <br /> Guard I 11.11111111.111.1.1111111111111811.11111111.111.1.1111111111111811.11111111.111.1.1111111111111811.11111111.111.1.11111111111118 -- _ <br /> ill = <br /> —— <br /> 36"min <br /> i__._, ! I 3'x3'min <br /> landing <br /> 3'x 3'min ��..-------,---��..� <br /> landing M <br /> — 3' One unit vertical in twelve units horizontal _ 3' _ <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> R311.2 Means of Egress I YES NO <br /> R311.2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. Er. 0 <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). 0' 0 <br /> R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry [a'--0 <br /> without use of key,tool or spec owledge. Required exit door shall have no additional locking devices. <br /> R311.7 Stairways N/A YES NO <br /> R311.7.4.1 Riser Height:Max riser height shall be 7% inches(8 inches in structures built prior to July 1,2004) 0 0 <br /> R311.7.4.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures built prior to July 1,2004) 0 0 <br /> R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple 0 0 <br /> risers.Handrails shall be installed in accordance with R311.7.7.1—R311.7.7.4 <br /> Effective: 2013 July 01 7.. <br /> Updated: 2013 June � � <br />