Laserfiche WebLink
a <br /> PT 2K6 SILL PLATE W/5/8"dia,x10" <br /> ANCHOR BOLT.EMBED MIN 7"INTO <br /> � <br /> CONC.&WITHIN 12"OR SILL ENDS , <br /> 5/8"x 12"A.B. @ 48"oc, <br /> W/3"x3"x1/4"STL WASHERS <br /> SPACING PER PLAN 12"from each end, min. 7" CB44 OR PER PLAN <br /> CONT.SEALANT JOINT embed(uno}&BP 5/8-2 PL ' <br /> O/NIIN.R-10 RIGlD IiUSUL. ��2° Expansion Joint CONC.PAD FOOTING <br /> THEi2�1AL BREA�(@ 4"CONC.W/WWM fc=2,500 PSI <br /> COtVDiTION�D SPACES O/4°GRAV L _ <br /> � (5EE PLAN) <br /> � � E.N. � <br /> x- - ��- <br /> �II I . ' a " a 4 a CONC.SLAB,REF. <br /> �i � , 4 <br /> � LL 2 # TOP&BOTT <a , , '<� - a X ' D <a - a- �� � Q ° v4 v <br /> I D�- _ ;. ' _ A. . a � " ; _ _ n a 1 1/4" - <br /> �1�� ' .� Y�4. � r++ l �� • • 4 Q° � ° ° ;— . <br /> °" � � CONT.KEY CONC.SLAB PER PLAN <br /> s , <br /> � #4 @ 48"oc EW �t(� �� ��� —����\�\\��\�\\/ °" �\\/�\�/\/� � ' ° ° v a ° <br /> z � ,/ /// 0 9 a, /// - - <br /> � �' �+�r �'��!��� q ����� _ a a Z � . <br /> �i , <br /> � I - % a �9 4 �i o a ° � <br /> � ' ° � i— . . 4 s • <br /> (2)#4 BARS CONT. � ° conc.fonting per plan ° a � , , <br /> � °q , <br /> � ENTIRE FOOTWG. �p , a4 � w/min. 1-#4 T&B a va ° � � � � <br /> 3"MIN.ABOVE BOTT � Stuctural Notes take " a ° <br /> 16° oF FTG ('1) No. 4 Bar Horiz. <br /> precendence <br /> 10" SEE PLAN <br /> � <br /> FOOTING. DE7AIL SLAB � FTG. DETAIL TU�NDOWN at GARAGE DOOR POST FOOTING D�TA1L � ' <br /> � 2 3 TYPICAL SLA� CONSTRUCI�ION JOINT � � , <br /> 4 5 � <br /> �� <br /> � <br /> STRUC°TURAL NO�'ES �Y � , " <br /> CASH CARR ENGINE�I�INC� � <br /> TAKE PREC�DENC� � <br /> � <br /> � <br /> � <br /> wsEc � - <br /> � . <br /> CHAPTER 4, PRESCRIPTIVE � � <br /> I�O�OF CtJiVSTRUCTION- � _ <br /> �lazing Max: � <br /> METAL ROOF <br /> O/30#BUILDING FELT %of Floor U-value Vertiral Unlimited � ,� � <br /> U-factor Vertical .30 � � � <br /> 0/1/2"APA RATED PLYD SHTG. DOOR U-value.20 � � <br /> O/RFTRS OR TJI Per Plan ��i��� � � � � <br /> 1"AIRSPACE W/INSULATION BAFFLE. J� (U <br /> R38 BATT INSULATION �XTEND 12"ASOVE WSULATION PER CODE With Attics= R-valu�49,Vaulted=R-value 38 Single �" (f� � � <br /> 6 MIL.VB, WARM SIDE ROOF CONSTRUCTION- rafter orjoist vaulted ceiling w/min. 1-in.vented � p� "f� <br /> 1/2"GWB, PAINTED � � <br /> �/ -a-e+ <br /> METAL ROOF airspace above the insulation. � � � � <br /> 3s°oH O/30#BUILDWG FELT �JV�ils: � �� - <br /> 0/1l2"APA RATED PLYD SHTG. 1.Above Grade Wall R-Value 21 intermediate frm � � ' <br /> 9� � � C°U lJ�l � <br /> � 6x12 False Beam O/RFTRS OR TJI Per Plan 2. Neaders insulated minimum R-10 � ; <br /> ����I( l ���l � R38 BATT INSULATION <br /> l�`�'" DBL � 2x VENT BLOCKS W/ 3 2 DIA.WIRE . <br /> � t � 6 MIL.VB, WARM SIDE 1"AIRSPACE W/INSULA710N BAFFLE. <br /> PL � ° <br /> SCREENED VENT HOLES @ EA. BLOCK <br /> � 1/2"GWB, PAINTED EXTENQ 12"ABOVE INSULATION PER CODE <br /> � 1"AIRSPACE W/tNSULATiON BAFFLE(if insulated) <br /> r-- <br /> � <br /> • EXTEND 12"ABOVE INSULATION PER CODE <br /> � <br /> � <br /> � <br /> � ROOF CONSTRUCTI�N - <br /> �� E3CTERIOR WALL- g (� METAL F200F <br /> � SIDING PER ELEV. ��J l� 2x B�R�B�K'G W/2"SCREENED <br /> � l��� " O/30#BUILDING FELT <br /> � O/T Y V E K H O U S E W R A P � � 2x VE N T B L O C KS W/ 3 2" DIA.WfRE ENT HOLES 1/4��CORROSION <br /> � ) 0/1/2"APA RATED PLYD SHTG. ,�� <br /> DBL RESISTANT METAL MESH <br /> � LAP WEATHERPROOF MEMBRANE 4"MIN. ''= SCREENED VENT HOLES EA. BLOCK � j <br /> � p� � @ O/16' 7J1 Per Plan COVERING o <br /> � r--- <br /> � O/1/2°APA RATED PLYWD SHTG � R38 BATT INSULATION (OPTIONAL � � <br /> = c <br /> S�CCJN D L�V�L � 0/2x6 STUDS @ 16"qc(W/R21 BATT INSUL) � 6 MIL.VB,WARM SIDE 'c� � <br /> Q <br /> � 1/2"GWB, PAINTED � 1/2"GWB, PAINI'ED � � � <br /> � � 2x6 FIREBLOCKlNG PER CODE � � ai � <br /> � APPROVED VAPOR RETARDER � � v <br /> � WILI.BE PROVIDED ON THE WARM �c�{--v'" �•C. �7�.��, � r���.1', �1�,�, DBL 2x6 RE-FIN 26 GA. C � �� '� <br /> � TOP PL METAL GUTTER � � � � <br /> � SIDE OF INSULATION PER WSEC �tA :�, � <br /> � 2��� O/1x12 CEDAR FASCIA � � � � <br /> � 502.1.6.1, INCLUDING AT RIM JOIST _ <br /> � � v � � <br /> ^ AREAS WITHW FLOORASSEMBLIES -� � � ��4 <br /> TYPICAL FLOOR � EXTERIOR WALL- � � CL � i;�' x <br /> zs ' <br /> FIN per plan 1/2"PART. BD. UNDERLAY � SIDING PER ELEV. � � � � � <br /> � O/TYVEK HOUSE WRAP = � �. ^ <br /> (WHERE APPLICABLE) --- - - ~ Rim board cont.1-1/8" LP SOIId StaC't OS� G���� TERiOR WALL ASSEMBLY � � o N <br /> LAP WEATHERPROOF MEMBRANE 4" MIN. [� („y� � d � <br /> O/3/4" PYLWD SUBFLR ���"! �{4f���' or 1-1/4" LVL rim bd. FIR�T LEV�L O/1/2"APA RATED PLYWD SHTG SIDING PER ELEV. � <br /> (GLUE AND SCREW) �B� O/HOUSE WRAP <br /> O/TJI @ Per Plan TOP PL Rim joists shall be in�ul�ted and includs 0/2x6 STUDS @ 16"oc(W/R21 BATT INSUL) LAP WEATHERPROOF MEMBRANE 4"MIN. <br /> 1/2"GWB CEILWG the air b�rrier 1/2"GWB, PAINTED <br /> PT 2x6 SILL P�ATE Wi 1/2"dia.x1o" O/1/2"APA RATED PLYWD SHTG or equal <br /> ANCHOR BOLT.EMBED MIN 7"INTO 0/2X6 STUDS @ 16��OC <br /> — CONC.&WITHIN 12°OR SILL ENDS (W/R21 BATT INSUL-OPTIONAL) � <br /> W!3"x3^x1la°STL WASHERS 1l2°GWB (INT.SIDE), PAINT � <br /> FI RST LEVEL PT 2x SILL PlATE W/5/8"dia.A.B. SPACING PER PLAN } * <br /> EMBED MIN 7" INTO CONC. & <br /> PT 2x SI�L PLATE W/5/8"dia.A.B. grade-SLOPE AWAY <br /> �MBED MIN 7"INTO CONC. & WITHIN 12" OR SILL ENDS FROM WALL @ 6"70 10' <br /> KEEP BOTTOM�F DRYWALL = WITHIN 12"OR SILL ENDS KEEP BOTTOM OF DRYWALL � W/3"x3"x1/4"STL WABHERS � <br /> 4"CONCRETE SWB '; <br /> 3/4"OFF FINISHED FLOOR. — 3/4"OFF FINISHED FLOOR. ~ SPACWG PER PLAN w/6x6 10/10 WWM � , � Fin. Gr. � <br /> /3"x3"x1/4"STL WASHERS , � <br /> INSTALL CAPIL.LARY BREAK _ INSTALL CAPILLARY BREAK NON-POURUS SILL SEAL AND o/6 MIL BLK V.B. <br /> � .,:. . , �, ,., <br /> SPACING I'�R PLAN C� <br /> 4"CONC. SLAB OR 1/2" PLASTIC SPACER -- OR 1/2"PLASTIC SPACER CAPILLARY BREAK o/4^GRANULAR FILL #4 Yert. �48"oc � <br /> NON-POURUS SILL SEAL AND <br /> W/WWF 6x6 W1.4 x W1.4 CAPILLARY BREAK Exterior 4"Conc. Patio _ � � � � <br /> RADIANT IN FLOOR HEAT per pian — 4" CONC. SLAB — Per Pla� � � � <br /> : , , _ f .; W/WWF 6x6 W1.4 x W1.4 (2)#a BAtzs coNT. 12° ~ <br /> 0/R10 RIGID INSULATION � » ' ° � � <br /> � � , <br /> • RADIAN7 IN FLOOR HEAT per plan _ _ _ , ALL REINFORCEMENT MUS7 BE 3°MIN.ABOVE BOTT � <br /> O/6 mii VB °� ° '�5 T� °° ' y�' ONT. SEALANT JOINT � — — <br /> , <br /> , ` <br /> , <br /> � , , _ <br /> � <br /> � - � 0/R10 RIGlD INSULATION 'ONT.SEALANT JOINT TIED INTO PLACE FOR OF FTG ,C��C W � � t <br /> . � . . .� �_. . . . . . � ,' =� ° ' , s �-o� � <br /> O/4"CRUSHED WASHED GRAVEL , �u �j- O/MW. R-10 RIGID INSUL. O/6 mil V� � 4� O/MIN. R-10 RIGID IiVSUL. FOUNDATION INSPECTION �`��:�vV�LSli C�+� � � ~ � <br /> �, ! <br /> � THERMAL BREAK „ THERMAL BRERK �...P 4.��}�-�^ �G'�O� � � � <br /> FOOTING O/4 CRUSHED WASHED GRAVEL sEe nETai��/a-�o �,� � <br /> �EE DTL 1/A-10 a��",+ � � � <br /> �' > , �,; , <br /> � w - � <br /> FOR ALL Df2AINAGE SYSTEM <br /> STRUCTURAL NOTES BY S�E CIV1L ENGINE�RING SHEETS . ,�� �f��}��,�r�; ,{�ct� - DATE: 6/5/2017 <br /> �':� �V..��)[4t�l�.l�`r ��4� � <br /> CASH CARR ENGINEERING <br /> �'r, _...._...-•� ,t: <br /> TAKE PRECEDENCE � t�. ���s ��e�� . <br /> T��-��� SCAL�: 1/4�� <br /> TYPICAL 2 STORY WALL �EGTiON TYPICAL GARAGE WALL SECTION J��: - � <br /> TYPICAL 1 STORY WALL SECTION . , <br /> � � � �. <br /> SHEET: <br /> � <br /> hese pl�ns M�Y NOT �� r�produced without specifi <br /> permission o� E�� I�esidential �esign, Marysville, WA <br />