� . „ 2 , �, � 4 5 6 7 g g LEGE�ID �
<br /> 2 3 -9 2 3 -9 2 3'-9" 23'-9" 1 9'-7 1/2" 1 9'-7 1/2" 19'-7" 23'-4"
<br /> CEILING PANELS (SEE STRUCT)
<br /> � AIR DIFFUSER (SEE MECH)
<br /> HIG A1TIC HIGH ATTIC _
<br /> � LIGHT (SEE ELECT) �
<br /> �
<br /> ¢ � ACCESS HATCH � '
<br /> � W
<br /> � � � � � I I I � � "' E4UIPMENT HATCH �
<br /> iz
<br /> 0
<br /> � EQUIP HATCH ACCESS HATCH � `�' ~
<br /> 1 A282 A501 1 A282 A500 Z Z 2 � ZONE OBSTRUCTED BY UTILITY TRACK BELOW ATTIC
<br /> _ �
<br /> ¢ o
<br /> MATCHLINE — FOR CONTINUATION SEE 1A280 � �
<br /> � — �
<br /> �.� � �.� � .
<br /> ��
<br /> � ��.i.� i �:��" ��� /, , � � � � l�� � , % ;/Tl i - /. �'T ��. lT / , ���T/,� � /T ��.7T� � / T i�i ���T% �� i i ,- , /,T��� � �'�::/ i � � ��ii��TlT/-/Tii� �
<br /> � �T, �
<br /> ��/T i�ll�-iiiiiilT,�. /; ��- � ��� � ��T/; , � i �T�� / T/T,� ii/ ��T� ,� � i /�i /, l,'i�" i / � i/, �� /Ti/,-T� /,;� ,� i; � T/, � ,' �/7� T/, ,�/ %- � i ,� ���TTI i / � , T/, �, ,T/Ti , l/�����, .
<br /> � � �� �� � N !
<br /> �/—�—�� \
<br /> 7� � -�� � /� �� _ ��. _ _ r_
<br /> �' ��L — �_ ������///� � �i�i�i�.�.��i'////,_ ///. � �� i �/ �_ ��i i //�// i�� �ii� /� /� / i, � �/�'L� � -���/ /�/,�� /- i / /_ ��/.� � ///� � / _i � / / %� . � ��_ /� / /� �
<br /> CATWALK SEE 2Al2 N I
<br /> — — — — — — — — �
<br /> I I � � I .
<br /> �L.L� �.L� �L � � .. ,
<br /> ,
<br /> — — — — — — — — — — — — — — — — — — — — — — �— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
<br /> � - - - - -
<br /> �.v 2 �.� � � � � 2
<br /> � � I I � 2
<br /> — � � E�IERAL NOTES �
<br /> �
<br /> HANGAR o . �
<br /> . -.. . _.. - ,
<br /> _- _ i�. �' �GLEASON' TRAK. SEE STACKER CRANE DWGS.
<br /> N
<br /> WALL ABOVE ��CRANE RAIL. SEE STACKER CRANE DWGS. '
<br /> �� 2 �� � � lL � � ( 2 I I I PER STRUCT
<br /> - - - - - - - - — — — � - - - - —
<br /> - - - — - - - - - - - - I- - - - - - - - - - - -
<br /> - - _- - - - J
<br /> STILL �� �� � � � HAN AR 2 R E�E R E�l C E D RAW I N G S �
<br /> ROOM B Y �
<br /> 140 � I � � � I I 45_003_1A5
<br /> I 45 OQ3 1A280 ,
<br /> � - - - - - - - - � 45-003-1A281
<br /> 45-003-1A283
<br /> �T�iilT/-1 � /, _ , /�T fTll ��ii%» � � � � � �� ' _ ���T/ ��, i�ll, , Tl, � � " � � l� � � � - - -� - - -7-T - � � CATWALK SEE 2Al2 �� 45-003-1A284 ��
<br /> i � i .�i /, /���/,�Ti i , /�/, /-��Ti i- � i l//-, _ �� /, �/ /, , . ,� /�1-�-_/,�/ /„ � /,� � 45-Q03-1A285 �
<br /> �L� L�.� 1 �L� �L � �� - - ���
<br /> i�
<br /> N
<br /> ���-�- - , � _ ,�� , � . ,, �� ; _ ; ,�, , . ,� , , % ,� � ; , � � ,, , � _ . � „ ,� , , � , � ,_ , , ; , , �� ,� � � � , � ,, , , � COI� STRUCTI0 �1 �I T
<br /> � � — � 0 ES
<br /> � � T/,- �-_ �,/, i%T/ 1�71,?T� � � /��T i; � �li T�� , �,� l , � �: l; � i /_�T/; � iTIT/�T, - , � l �� , i,���� � i ,' , /� / �� �� " , ��i�� � ITi�T/ll i� � _
<br /> �� � � - - 1 ' EXISTING CEILING TO BE MODIFIED THIS AREA. SEE STRUCTURAL �
<br /> �„� � � DRAWINGS S462R & S462 FOR ADDITIONAL INFORMATION AND .
<br /> SCOPE OF MODIFICATIONS.
<br /> ELECTRICAL � r\ � EXISTING LIGHT FIXTURE TO BE BE RELOCATED. SEE DRAWINGS
<br /> ROOM STA KER RANE UTILI
<br /> 1 E12R & 1 E12 FOR ADDITIONAL INFORMATION.
<br /> �3g PEN RATI N ( P 6)
<br /> � 2 �
<br /> � � �
<br /> I ,
<br /> STAIR "A" �
<br /> 138 A
<br /> _ — — — � . ,
<br /> � 1 9 15
<br /> FAN TYP �
<br /> MECH PIPING PENEfRATION ROOM - - - A
<br /> MECH (SEE MECH TYP 7 PLCS) MECH 132 � AC SS H TCH �
<br /> I ROOM � I 1A28 W5 0 I � � � 1A280 ,
<br /> �30 �31 1A281
<br /> — — — - G
<br /> — — — — — — �0 6 , .���
<br /> 1A282 1A283
<br /> STORAGE � PAINT GUN CLEANING PAINT VESTIBULE ;� ` '
<br /> 124 STORAGE ROOM PREPARATION 129A
<br /> °° M
<br /> �29 1 A285
<br /> -- -- -- 125 -- -- _128 __ -- — --
<br /> MATCHLINE - FOR CONTINUATION SEE 1A284 �
<br /> � 1A284
<br /> N
<br /> �
<br /> � W — — S
<br /> CEILING PANELS AND � v �
<br /> SUPPORT IN THIS , Z K�EY PLAN - BUILDING 45-003 N .
<br /> AREA PER STRUCT ,,,., o
<br /> zQ �
<br /> J =
<br /> = Z
<br /> ¢ 0 8' 4' 0 4' 8' 16' '. _
<br /> g V
<br /> �ow ATr�c HIGH ATTIC SCALE: 1/8"- 1 '-0" "
<br /> t�F AN �
<br /> �VI
<br /> D�N—H5 — 11 .21 , 1 N G I H E E R s :
<br /> 20 8
<br /> P A R T I A� P �A f� �I E W „o� 2�d,Suite 400�Seattle,WA 98,o,
<br /> � ph 206.623.0717�fax 206.624.3775
<br /> SCALE: 1/8��— , �—o�� I �SUE F4R CONSTRIJ �TI N coffman.com � _
<br /> � LASTING creetivit results releuonshl
<br /> Y i I as
<br /> r
<br /> SYM REVISION 8Y APPROVED DAlE SYM R�llISION BY APPROVED DATE Y S � DRAWN DATE SUBTITLE CURRENT REVISION SYMBO� DATE �
<br /> .�g J ACCEPTABILITY R PARCHEN os.z�.o5 PARTIAL FIRST FLOOR � � �
<br /> - RECORD DRAWING J#54716Q HGI/SEL 01.18.08 ,c�, �oF wAs�r� y THIS DESIGN AND/OR CHECKED 1786915 A 11 .21 .18 �
<br /> A 45-003 MODIFICATIONS HATCN QOOR RELOCATION 1786915 CEI/EO EO 11.21.18 / � Fe�`� � SPECIFICATION IS APPROV�D R GWINN 06.30.06 TITLE REFLECTED CEILING PLAN SHEE7 �
<br /> BOE/�� APPROVED BY DEPT. DATE R GWINN as.3o.os 45-003 MODIFICATIONS HATCH DOOR RELOCATION �
<br /> CHECKED 1 A2�2 R k
<br /> � � � L COSGROVE 06.30.06 �1
<br /> �p O�, 6 ti .c�W APPROVED B U I L D I N G 45�OQ V JOB N0. COMP N0. C
<br /> � RAL E���yti� S. LEHTWEN os.3o.os 547160 �
<br /> �
<br /> - SjONA� �� S PLUSK 06.3Q.06 ARCHITECTURAL MASTER COL G—M/1 -9 EVERETT, Wq, owc No. 45-003-1 A282R
<br />
|