My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
221 SE EVERETT MALL WAY 2018 RED WING SHOES Plans 2022-12-29 (2)
>
Address Records
>
SE EVERETT MALL WAY
>
221
>
RED WING SHOES
>
Plans
>
221 SE EVERETT MALL WAY 2018 RED WING SHOES Plans 2022-12-29 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2022 8:06:07 AM
Creation date
8/13/2019 4:07:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
221
Tenant Name
RED WING SHOES
Permit
B1808-005
Year
2018
Notes
TI FOR NEW TENANT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I . I � <br /> ��cH�-r���� . <br /> o � 4125 Lakeland Ave. N., Suite 200 � T <br /> ��� Minneapolis, Minnesota 55422 � <br /> E LECTR I CAL SYM B 0 LS PANELBOARD SCHEDUL�" 763-533-7171 fax: 763-533-�979 � <br /> ALL SYMBOLS DO NOT NECESSARILY APPLY � <br /> PANEL DE=SIGNATION: EXISTING PANEL "M2", RENAMED PANEL "L" _'���������� <br /> MOUNTING HT TO CEN7ERLINE BUS SIZE: 225 AMP <br /> SYMBOL DESCRIPTION UNLESS OTHERWISE NOTED CONFIGURATION: 120�208 VOLT 3 PHASE 4 WIRE � � ��y������`�"�� <br /> - MAIN SIZE: 200 ������� ����� <br /> ��������,� <br /> �d DUPLEX RECEPTACLE 18" AF� MOUNTING: SURFACE �������� �;. , <br /> a���\��������� <br /> INT. RATING SYS AMPS: 10,000 ������ <br /> �I DOUBLE DUPLEX RECEPTACLE 18" AFF LOCATION: ���� ��-�������.�'`�����.�°� <br /> � ,� <br /> �� .. <br /> GROUND FAULT INTERRUPTION RECEPTACLE RED WING SHOES <br /> , 0/C LIGHT RECEPT MOTOR MISC MISC MOTOR RECEPT LIGHT 0/C PHONE (p��E 9464RED��N(651�) 3s soas� � <br /> Q FLOOR OUTLET W/ DEVICE AS INDICATED <br /> CKT ITEM OR AREA SERVED P�tOT WATTS WATTS WATfS WATTS PH WA17S WATTS WATTS WATTS PROT ITEM OR AREA SERVED CKT � <br /> � CEILING MOUNTED RECEPTACLE 1 SPARE 2�/1 q 360 20/1 � <br /> CASHWRAP 2 <br /> ILLUMINATED EXIT SIGNS/EXTERIOR EMERGENCY AS REQUIRED 4 <br /> LIGHT. 3 SALES TRACK LIGHTING 20/1 408 B 360 20/1 CASHWRAP <br /> �-I JUNCTION BOX RECESSED WALI_ AS REQUIRED _ <br /> Q JUNCTION BOX CEILING MOUNT 5 SALES PENDANT LIGHTING/CEILING FANS 2G/1 156 2�� � 20/1 SPARE 6 . <br /> a.� SINGLE POLE SWITCH �6" AFF � STOCK ROQM/LIGHTS 20/1 333 A 200 20/1 OPEN SIGN 8 <br /> �. <br /> (SUBSCRIPT INDICATES SWITCH LEG) � EMERGEN�Y/EXIT/NL 2U/1 �2g B 540 20/1 GENERAL RECFPTACLES(SALES) 10 <br /> 3-Ff}I 3-WAY SWITCH 46" AFF * � t <br /> 4-ffli 4-WAY SWITCH 46" AFF 11 RESTROOhA LIGHTS & EXHAUST 2(J/1 44 180 100 � 360 20/1 WORK BENCH 12 � . <br /> FAN/GFI RECEPTACLE . <br /> Tc TIME CLOCK AS REQUIRED ❑ �3 DISPLAY 'NINDOW RECEPTACLES 2U/1 360 A 360 20�� WORK BENCH �4 �k " <br /> LC-1 LIGHTING CONTACTOR AS REQUIRED ,� �5 SECURITY BOARD 2(��� 500 B 720 20/1 STOCK ROOM RECEPTACLES/ WATER 16 � <br /> COOLER RECEPT. <br /> BRANCH CIRCUIT PANELS (250V OR LESS) 6'-0" TO TOP 17 SHELF LIGHTING 2��� 540 � 360 20�� TELEPHONE 80ARD �8 <br /> BRANCH CIRCUIT PANELS (277/480V) 6'-0" TO TOP RECEPTACLE AT PANEL <br /> 19 SPARE 20/1 A 1500 20/1 WATER HEATER 20 <br /> � DRY IYPE TRANSFORMER - SI'ZE AS NOTED -- • <br /> ON DRAWING 2� TIMECLOGK 2Q�� 100 g 72p 20/1 GENERAL RECEPTACLES(SALES) 22 <br /> `� NON FUSED DISCONNECT SWITCH AS REQUIRED — <br /> 23 RTU REC�PTACLE 2�1/� 180 � 1200 20/1 SIGN 24 ❑ <br /> FUSED DISCONNECT SWITCH AS REQUIRED . <br /> 25 SPARE 20/1 A 5760 20�� EXISTING RTU 26 . <br /> �I TELEPHONE OUTLEf — 1 DATA JACK PER 18" AFF <br /> OUTLET UNLESS NOTED OTHERWISE 27 2U/1 g 5760 28 <br /> SPARE . <br /> DATA OUTLET — 1 DATA JACK PER OUTLET 18" AFF 29 30 c'�������'����� ' <br /> � UNLESS NOTED OTHERWISE SPARE 2���� � 5760 <br /> � CEILING SPEAKER �� <br /> �5 F FIRE ALARM VISUAL SIGNAL 96" AFF <br /> (NUMBER INDICATES STROBE CANDELIA) " "`��--- ��.�-�"� <br /> �5 F FIRE ALARM AUDIBLE VISUAL SiGNAL 96 AFF <br /> � (NUMBER INDICATES STROBE CANDELLA) � t <br /> � ���� �i <br /> F� DUCT SMOKE DETECTOR ������� ,��., <br /> Q SMOKE DEfECTOR �o.--- � � ��� � <br /> os OCCUPANCY SENSOR AS REQUIRED ��` � # <br /> --� � <br /> os WALL MOUNTED OCCUPANCY SE:NSOR AS REQUIRED � � <br /> � <br /> � �,�8 � . � <br /> -�__ � �� a B c ��'`� ���������°����� <br /> � SECURITY SYSTEM CAMER,4 CONNECTED LOAD: 27.2 KVA 75.5 AMPS VA PER PHASE. 8873 9234 9080 � ����d���.���� <br /> � SECURIT`( SYSTEM MOTION DEf�CTOR �.� �����'�'���� <br /> Kp SECURIN SYSTEM KEY PAD— EiY OTHERS— COORDINATE INSTALLA�fION �` PROVIDE LOCK-ON DEVICE °PROVIDE: L(�CK--OFF DEVICE ° ROUTE THRU TIME CLOCK �� 1� � _ <br /> pc SECURITY SYSTEM DOOR CONT�CT <br /> F� PANIC BUTTON _ LOAD CALCULATION ������� ����������� <br /> ANY SYMBOL MAY BE FURTHER DESIGNA7ED BY <br /> ONE OR MORE OF THE FOLLOWING SU65CRIPTS: � <br /> TOTAL CONNECTED LOAD 27.2 KVA <br /> EM EMERGENCY <br /> NL NIGHT LIGHT �� ������� � <br /> MOTOR LOAD 17.6 KVA X 1.00 = 17.6 KVA <br /> W WALL MOUNTED 25� OF LARGEST MOTOR 17.3 KVA X .25 = 4.3 KVA �j�� �� ���,j`jj ����� <br /> MISC. LOAD 2.1 KVA X 1.0 = 2.1 KVA ly i� � <br /> WP WEATHERPROOF . <br /> LIGHTING LOAD 3.0 KVA X 1.25 = 3.8 KVA <br /> X EXISTING OUTLET/ DEVICE RECEPT. 1 ST 10 KVA � 100% 4.5 KVA X 1.0 = 4.5 KVA <br /> -,-- REMAINDER � 50� 0.0 KVA X .5 = 0.0 KVA �� � �� �� <br /> ��1 � ������ ��11 ���, ��-� <br /> TOTAL DEMAND LOAD 32.3 KVA �e��$t, �� g��0� <br /> CTS-13,24 AT 120/208V,3PH,4W 89.7 A <br /> � ��V������ <br /> � <br /> I <br /> EXISTING F'ANEL "L" � <br /> 30 POLE, REUSE r�� > <br /> EXISTING CIRCUIT .�--E`(ISTING TIME CLOCK <br /> ( �� R��PLACE IF REQUIRED <br /> BREAKERS, REPLACE LI J S�E SPECIFICA710NS <br /> WITH NEW AS . <br /> REQUIRED. MATCH <br /> EXISTING r —— � � <br /> MANUF"ACTURER, <br /> MAIN7AIN EXISTING � � �at�; 08,02�1$ <br /> SERVICE: FEEDER. ; <br /> ELECTRICAL CONTRACTOR TO FIELD VERIFY CAPACITY <br /> I I �x��� ��: ��� <br /> PROVIDE 200AMP CIRCUIT �REAKER AVAILABLE BY ELEC. I I • <br /> AND NEW MEATER IN THE EXISTING CONTRACTOR. � � ������� ��': N�� <br /> SERVICE ENTRANCE. EQUIPMENT TO I I <br /> MATCH EXISTING EQUIPMENT. FIELD � � ��b �� T���: 18R�-�18 � <br /> VERIFY L _ _ �J ' <br /> � <br /> � R1SER DIAGRAM _`�. <br /> N.T.S. ���@�, �n��r����.�� . <br /> � . , <br /> ' ��� , <br /> � <br /> COPYRIGHT 2018, ALAN J. PLUTOWSKI <br /> � <br /> 644�.F�5 , <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.