Laserfiche WebLink
-- , ___ <br /> , , <br /> + T - •Mobile- <br /> X X <br /> x — X — X -1 X — X — X —I =PROJECT INFORMATION: <br /> x x <br /> I EVERETT WATER TANK <br /> x (E)T-MOBILE BTS CABINETS (E)STEEL MONOPOLE X (E)T-MOBILE BTS CABINETS (E)STEEL MONOPOLE SE01605A <br /> (E)T-MOBILE ICE BRIDGE I (E)T-MOBILE ICE BRIDGE <br /> 319 76TH ST SW <br /> x x EVERETT,WA 98201 <br /> AD •4 V • D .pD .q y D <br /> x 'p 4 —ISSUED FOR: <br /> ' 'a p' • 4 • q ,. ° D' 4 D BUILDING PERMIT <br /> ° p• A °. .D ° <br /> x D. - D. • p p ® D x D. p ® p G D —REVISION HISTORY: CHK. <br /> N <br /> 4 <br /> I q• / •4' A ° p • 4 NO. DATE: DESCRIPTION: BY: <br /> 1 <br /> I j q Bf��?I I 'p - d 1 0. . \/ <br /> x A D �) p * x A Dom. �� Dr +lam. ► <br /> ° �. (P)8'DOUBLE SWING GATE I q• <br /> Air <br /> FOR GENERATOR ACCESS • 4' a. <br /> x q• ' '• .. .� .. A°D \ / D '' '4 • (P)3/4"U/G PVC CONDUIT /, <br /> I D • p p p pq ° D CTRL CTRL ° CTRL — CTFIS. U® p W/CATS ALARM CABLE <br /> x ° p (E)T-MOBIL POWERG N 7500 a. • ,–(E)T-MOBILE POWER/TELCO x . ' p 4 . D ° (E)T-MOBILE POWER/TELCO <br /> • ' GENERATOR MOUNTED ON CONC PAD Q EQUIPMENT MOUNTED ON(E)H-FRAME 4 ° D N q EQUIPMENT MOUNTED ON(E)H-FRAME <br /> D <br /> xJo 4 ■� <br /> I +/ V As P CTRL • <br /> P _ CCTRL P n 9/5/2018 REVISED PER REDLINES BJT <br /> I LI I II / \ 8/22/2018 ISSUED DESIGN REVIEW BJT <br /> \ rc (P)100 AMP SERVICE RATED DISCONNECT& =PLANS PREPARED BY: <br /> / (E)T-MOBILE 120 GAL PROPANE TANK 100 AMP SERVICE RATED TRANSFER SWITCH <br /> X «< // \\ MOUNTED ON(E)CONC.PAD ' ` (P)(3)#3 THWN W/(1)#8 GRN MOUNTED ON(E)H-FRAME B. J. THOMAS, P.E. <br /> \ �8'r=-- I GRD IN 1-1/2"PVC CONDUIT 7607 80TH AVE NE <br /> X / \\ / / / // `'/ F (P)1"PVC CONDUIT W/ V MARYSVILLE,WA 98270 <br /> I / 1 GENERATOR CONTROL WIRING 206-851-1106 <br /> / <br /> x / I +\ I D (E)T-MOBILE POWERGEN 7500 GENERATOR TO BE <br /> / I / + REPLACED W/(P)GENERAC#RG025 25KW GAS —DRAWN BY: CHK.BY: <br /> Icr <br /> // F. <br /> GENERATOR MOUNTED ON(P)8'x 3'-11"CONC PAD <br /> (POURED IN PLACE) <br /> x \ I / \ + o a .• "s <br /> 1 I (SEE SHT.A-2 FOR DETAILS) JL BJ <br /> \ i <br /> x \\ / / (E)BUILDING 'r x c, ;N, e D• <br /> N W/CAT5 ALARM CAB EUIT (E)BUILDING —LICENSURE: <br /> N <br /> I I3'-6" \\\ c i+o.y <br /> \ / <br /> N\ / // °s < (P)3/4"0 PE PIPPING FOR , - o <br /> LPG FROM PROPANE TANK/ <br /> IFF���� 7 <br /> N._,___________ <br /> ___ x TO GENERATOR �' <br /> 3, I likkizza,i47:4ii cv <br /> (E)5'CLEARANCE SETBACK 1 I I NOTE: =DRAWING INFORMATION: <br /> \ / DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY <br /> I 6 / PROPANE TANK SHALL HAVE A REGO-7502 1-1/4" ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> / \ M-NPT FILLER VALVE W/MANUAL SHUTOFF ERRORS AND OMISSIONS.ALL PREMUS ISSUES OF THS <br /> X \ X 3' / DRAWING ARE SUPERSEDED BY THE LATEST REVISION. <br /> THE INFORMATION CONTAINED IN THIS SET OF <br /> DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR <br /> \\ I / DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED <br /> X \ X // (P)5'CLEARANCE SETBACK CLIENT IS STRICTLY PROHIBITED. <br /> I N N I <br /> '� =DRAWING TITLE: <br /> X x– <br /> I I (E)T-MOBILE 120 GAL PROPANE TANK TO BE ENLARGED <br /> x x RELOCATED&MOUNTED ON(P)3'(PRECAST OR OUREDINPLACE) x 3'x 4"CONC.PAD SITE PLAN <br /> (SEE SHT.A-3 FOR DETAILS) <br /> x x <br /> —DRAWING NUMBER: <br /> x EXISTING ENLARGED SITE PLAN X PROPOSED ENLARGED SITE PLAN <br /> I 22x34 SCALE:1/2"=1' I22x34 SCALE:1/2"=1' <br /> x 11x17 SCALE:1/4"=1' x 11x17 SCALE:114"=1' . <br />