GENERAL YES NO <br /> Bathroom doors a re easily and quickly openable from the outside when locked l- 0 <br /> Carbon Monoxide alarms a reinstalled as required i n R315 on each level of the home. ID' 0 <br /> Smoke a I arms are installed on all levels of the dwelling,in each resident sleeping room,outside each separate <br /> sl eepi ng area i n the i mmed iate vi ci nity of sleeping rooms(R314). a0 <br /> Smoke and Carbon Monoxide alarms a reinstalledinsuchamanner sothatthe audiblewarningmay beheard inall ®/ <br /> parts of the dwel ling upon activation of a single device. <br /> Access road and water supply meetlocalfirejurisdictional requirements. Er 0 <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twistingofthe wrist(lever-type). 0 <br /> Pocket doors shall have graspable hardwareavailablewhen in the closed or open position. 0-, 0 <br /> R311.8 Ramps YES NO <br /> Inside Ramp N/A err0 0 <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) 0 0 <br /> R311.8.2 Landing Requirements:min.3X3 foot landingattop/bottom,where doors open onto ramps,and where rampchanges <br /> directions. 0 0 <br /> R325.9.1 Handrails required o h sides of ramp in accordancewith R311.8.3.1—R311.8.3.3. 0 0 <br /> Outside Ramp N/A Ir YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) 0 0 <br /> R311.8.2 Landing Requirements:min.3X3 foot landingattop/bottom,where doors open onto ramps,and where rampchanges 0 0 <br /> directions. <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. 0 0 <br /> Guards below are depicted vertically as an example only.All Ramps must have Guards 0 0 <br /> Handrail both sides <br /> — Less than 4" /34"-38" <br /> Guard <br /> 36"min <br /> 3'x 3'min <br /> landing <br /> ------- <br /> 3'x3'min — <br /> landing ......�,� a . <br /> 3' One unit vertical in twelve units horizontal I 3. — <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> R311.2 Means of Egress YES NO <br /> R311.2 Door must be side-hinged with min.width of32 inches between face of door and stop.Height not less than 78 inches. Er 0 <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). Cr 0 <br /> R325.4 Required exit door hardware shall unlock inside and outsidemechanismswhenexitingthebuildingallowingre-entry m/ 0 <br /> without use of key,tool or special knowledge. <br /> R311.7Stairways N/A Q 'Fl rer7 61vZ YES NO <br /> R311.7.5.1 Riser Height:Max riser height shall be 77'/ inches(8 inches ins ructures built prior toJuly 1,2004) 0� <br /> R311.7.5.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures built priortoJuly 1,2004) [� <br /> R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple L7a i/0 <br /> risers.Handrails shall be installed in accordance with R311.7.8.1—R311.7.8.4 <br /> Effective:2013 July 01 <br /> \ Updated:2017 February <br />