My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2920 107TH ST SE 2019-08-14
>
Address Records
>
107TH ST SE
>
2920
>
2920 107TH ST SE 2019-08-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/14/2019 10:25:23 AM
Creation date
8/14/2019 10:25:23 AM
Metadata
Fields
Template:
Address Document
Street Name
107TH ST SE
Street Number
2920
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,°H-' WAC 296-46B- 00: ELECTRICAL PLAN REVIEW <br /> DIRECTIONS:Read the WAC section below to determine if plan review is required or not required.Then Select the box next to,(a)to <br /> tell City Staff if plan review is not requried and selectthe box next to the specific reason frorr►WAC 296-46B-900.If plan review is <br /> required,select the box next to(b)and(c)to-acknowledge that plan review is required and the electrical plans have been provided <br /> with this permit application. <br /> *If item(a)-(ii,hi,or v)is selected,the work must also comply with section(a)-(vii).See arrow flow than below. <br /> (3)Electrical plan review. <br /> [] (a)Electrical plan review is:not required for: <br /> O (i)Low voltage systems; <br /> •t�--O (ii)Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> (iii)Heating and cooling specific retrofit projects that result,in an electrical load reduction on each existing feeder <br /> involved in the project,provided there is not a corresponding increase in the available fault current in arty feeder, <br /> (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the project's distribution system <br /> d does not include: <br /> (A)Emergency systems other than listed unit equipment per NEC 700,12(F); <br /> (13)An electrical system defined in NEC 517.2;or <br /> (C)A required fire pump system. <br /> 4--0 (v)Modifications to existing electrical_installations'where all of the following conditions are met: <br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground;: <br /> (8)Does not involve emergency systems other than listed unit equipment per NEC 70012(F); <br /> (C)Does not involve branch circuits or feeders of en essential electrical system as defined in NEC 517.2: <br /> and <br /> (D)Service or feeder load calculations are increased by 5%or less. <br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell,or wind electric system(s)with a total <br /> fl rating of 9600 watts or less. <br /> (viii For installations in(a)(il),(iii),and(v)of this subsection to be considered,the following must be available <br /> to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are,providing bothbefore and after panel schedules as needed:and <br /> (D)Provide information showing that the service and feeder(s)supplyingthe panel(s)where the,work is <br /> taking place hes adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE:Electrical planreview is not required for"Medical,dental,and chiropractic;clinic"of which is a clinic or <br /> O 'physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more,per section <br /> (1)(0)(xii).,• <br /> 1—t (b)Electrical plan review is required for all other newor altered electrical projects in educational,institutional,or health care <br /> L.--J occupancies defined in this chapter, <br /> (c)If a review is required,the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> table 90x.3 ,Taal!90D•2 <br /> Health or Personal care r.ciktaes' Educational and Institutional facilities.Places of Assembly.or Other Facilities• <br /> Health or Personal Cara Facility Plait ReviewEducational,Institutional.or Paan Revierp <br /> Type Required• <br /> KKP °titer facility Types. Required <br /> t "avLCat VIA <br /> f r <br /> a5::5trd hzurig foci,'EX <br /> D'vote e''cehe'x»,10: its 'ei Notes to"rabies 900-1 and 9002. <br /> Pp:,gate t•.5n tat •a;_ ;itv-atte rszCtt tC cl:eject :2t tYlCIC Ct•n•�3 <br /> vat.„tf o, •'ed -mar.Qqu€e p.an;xe.‘ea.on face,t;t;;At./clot <br /> -rbu ars;.•:,-"+ F¢e;'ac i'>` "e' re`:cr.eo^“ ceoa.'t"reit.. <br /> lana 'ter':'3 a;SI:C.ih•."._..,..._.._ s ^. ...... <br /> wr x ;e i r o f ;' <br /> a IL e3'ae't a fe+iab=,caz; as PERMIT# Page 2-Plan Review <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.