My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
620 112TH ST SE SPACE 375 2019-08-16
>
Address Records
>
112TH ST SE
>
620
>
620 112TH ST SE SPACE 375 2019-08-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/16/2019 8:47:47 AM
Creation date
8/16/2019 8:47:34 AM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SE
Street Number
620
Unit
SPACE 375
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. PPS illil <br /> S try N i�. t .y„ 7> 1 '3 ��• til <br /> -- Coafimns o ',:%A44'. + t <br /> .4./,, <br /> -a i,, HUD MIIICSS ,,,Witaw;' <br /> 10/20/08 <br /> EXTERIOR SIDEWALL <br /> 0.035 X 1 IOC TIE-DOV.TI EXTERIOR S1OEWALI. <br /> STRAP OR BRACKET OITERgR CROS$IAE0.78ER <br /> T INSTALLED AT FACTORY -r 0 035 X 1 113'TIEDbi N <br /> ♦ 1/ STRAP OR BP.aCXET <br /> INSTALLED AT FACTORY MAW ABEAM <br /> / 11 V al-r Lt // 1f —_ <br /> V �- MAIN 1.13641A i.e W I ```��_. ,=,.- _ _ — <br /> "- —_ O DOUBLE._ _ <br /> R. HEADED `-__� <br /> 3 `\1- i, <br /> _ <br /> �_2 f ,-- �WTERIOR u W u+CHCR <br /> ,¢O <br /> ,'- j CROSS IdEIdE_R <br /> ,- Z t--_ / 0035X1IfeTIEDCVN - j1 <br /> STRAP FUR/101E0 BY INSTALLER I <br /> I i i-GROUND LE'i EL — ____ __._-.._ t <br /> i <br /> f I 0.035%1 uc TIE-ooit I —GRCUNDLK.EL <br /> _ GEE MOTE 3II STEP I- <br /> I <br /> STRAP FURI1rJ-1ED BY INSTALLER <br /> , I <br /> Anglo of swim.wfien no sla4YM,I&N..is us W <br /> Figure 66. Lateral tie-down con- <br /> STEP 2. DETERMINE TIE-DOWN CONFIGURATION figurations <br /> There are two primary tie-down configurations: the near beam and the far beam meth- <br /> ods. (Figure 63). <br /> • Near beam method. For all Wind Zones,connect an anchor strap from the <br /> anchor head to the beam closest to the anchor. See Figure 67. In-line anchor <br /> configuration and Figure 68. Stabilizer plate configuration.For Wind Zones II <br /> and III connect a vertical strap from the sidewall factory installed tie of the <br /> home to the anchor head using a double-headed anchor;connect the other <br /> strap to the beam closest to the anchor. Refer to Table 22 for maximum <br /> heights from ground. <br /> • Far beam method.For Wind Zones II and III connect one anchor strap from <br /> the anchor head (using a double-headed anchor)to the home's near beam or <br /> far beam and one to the sidewall of the home. Refer to Table 23 andTable 24 <br /> for maximum heights from ground. <br /> STEP 3. SELECT ANCHORS <br /> Use the torque probe results from Prepare the Site,STEP 5.DETERMINE SOIL- <br /> BEARING CAPACITY AND FROST LINE(p. 14)and the anchor manufacturer instruc- <br /> tions; select the type and length of anchor to use.The installed ground anchor size <br /> (length)must be listed (i.e.approved)for the soil class. <br /> Make sure the anchor is of sufficient length such that the top of the helix is below the <br /> frost line. Select a shaft diameter sufficient to resist excessive torsion,"ring-off" (when D <br /> the helix or anchor head separates from shaft)or shaft splitting. Consult the anchor D <br /> supplier for guidance. <br /> ..a <br /> Review all of STEP 3. INSTALL ANCHORS(p.69)and STEP 4.INSTALL STRAPS = <br /> (p. 70)before making final anchor selections to determine when single-headed vs. 7J <br /> double-headed anchors should be used. Follow the specifications in Table 30 when se- m <br /> O <br /> letting stabilizing system components. 73 <br /> TABLE 30.ANCHOR SYSTEM MATERIALS SPECIFICATIONS 0 <br /> Component Specification m m <br /> .., .e.» ;,.,,,t..,_ok.. ,v, ,�- CA <br /> Anchors must be tested and listed to resist a minimum ultimate load of-f,725 lbs and a minimum allowable <br /> i working load of 3,150:lbs or ultimate and corresponding working load limited by soil conditions and anchor . U3 <br /> Anchors length.The working load is the maximum load the designer can use.Ground anchors must be provided <br /> with protection against weather deterioration and corrosion at least equivalent to that provided by a coating '' <br /> of zinc on steel of not less than 0.30 oz per sq ft of surface coated. r- <br /> Straps must be minimum 1-114"x 0.035"zinc-coated(0.30 oz per sq ft)steel strapping conforming to <br /> Straps ASTM D3953-97,Type 1,Grade 1, Finish B with a minimum allowable working load capacity of 3,150 lbs C <br /> and a minimum ultimate load of 4,725 lbs.Slit or cut edges of zinc-coated strapping do not need to be zinc 1 <br /> coated. <br /> > <br /> The size and type of stabilizer plate,if required by the ground anchor manufacturer,will be specified in the ' <br /> anchor manufacturer's instructions.Stabilizer plates must be provided with protection against weather } <br /> Stabilizer plates deterioration and corrosion at least equivalent to that provided by a coating of zinc on steel of not less than <br /> — 0.30 oz per sq ft of surface coated.Altematively,ABS stabilizer plates may be used when listed and cerci- <br /> fed for such use. <br /> n r <br />
The URL can be used to link to this page
Your browser does not support the video tag.