Laserfiche WebLink
z ' Washington State Energy Code:Cnent Performance Worksheet,Type R-3 Occupancies <br /> George D.Deasy AIBD SKOLAND RESIDENCE <br /> 1304 Hillcrest Parkway <br /> Mt Vernon,WA.98274 <br /> 360-428-4819 <br /> Heating System Size <br /> Ducts are located in unconditioned space: <br /> Conditioned Floor Area 275 Equipment size over design load 1150`.. <br /> Conditioned Building Volume 200 Btu/hour output 8,025 <br /> Weather Statio)Everett Paine AFB V KW 2.4 <br /> Component Performance,R-3 occupancies Code Target Values Proposed Design Values <br /> Area UA Area UA <br /> Vertical Glazing U= 0.300 41 12.4 97 29.0 <br /> Overhead Glazing U=0.500 0 0.0 0 0.0 <br /> Doors U= 0.200 0 0.0 0 0.0 <br /> Flat/Vaulted Ceilings U= 0.027 275 7.4 275 7.4 <br /> Wall(above grade) U= 0.056 314 17.6 259 21.0 <br /> Floors U= 0.029 275 8.0 275 8.0 <br /> Slab on Grade F= 0.360 0 0.0 0 0.0 <br /> Below Grade <br /> 2'depth,wall U= 0.042 0 0.0 0 0.0 <br /> 2'depth,slab F=0.590 0 0.0 0 0.0 <br /> 3.5'depth,wall U=0.041 0 0.0 0 0.0 <br /> 3.5'depth, slab F= 0.640 0 0.0 0 0.0 <br /> 7'depth,wall U= 0.037 0 0.0 0 0.0 <br /> 7'depth,slab F= 0.570 0 0.0 0 0.0 <br /> Target UA Total 45.4 Proposed UA Total 65.3 <br /> Target Credits from Chpt.9 1.0 Proposed Credits from Chpt. 9 1.5 <br /> If the Proposed UA s the Target UA,and the Proposed Credits From Chpt.9 are z 1 than the home meets the 2009 WSEC. <br /> Check other code requirements <br /> /a) <br /> (;)9- <br /> Copyright 2010,WSUEEPIO-009(Version 10)Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) <br /> 1/4/2013 �ef0' <br />