Laserfiche WebLink
• SECTION 5.0 POST SPACING,POST TYPE AND FOOTING SIZE FOR SOLID COVERS <br /> Ground Snow Load: 30 .sf Live Load: 20 .sf Roof Desi:n Load 29 •sf Wind S•eed: 115 MPH EXPOSURE B Seismic Ss= 150% Seismic Desi:n Cate:o D Freestandin: or Attached <br /> cubic footing"d" cubic footing"d" cubic footing"d" cubic footing"d" cubic footing"d" cubic footing"d" cubic footing"d" cubic footing"d" cubic footing"d" cubic footing"d" cubic footing"d" <br /> Table 5.25 Constrained Constrained Constrained Constrained Constrained Constrained Constrained Constrained Constrained Constrained Constrained <br /> trib Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) Crib Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) <br /> Post Footing Max Post Length Post Footing Max Post Length Post Footing Max Post Length Post Footing Max Post Length Post Footing Max Post Length Post Footing Max Post Length ! Post Footing Max Post Length Post Footing Max Post Length Past Footing Max Post Length Post Footing Max Post Length Past Footing Max Post Length <br /> Header Detail 3' Type lin) 8' 12' 15' 3.5' Type (in) 8' 12' 15' 4' Type (in) 8' 12' 15' 4.5' Type (in) 8' 12' 15' 5' Type (in) 8' 12' 15' 5.5' Type (in) 8' 12' 15' 6',Type (in) 8' 12' 15' 6.5' Type (in) 8' 12' 15' 7' Type fin) 8' 12' 15' 7.5' Type (in) 8' 12' 15' 8' Type On/ 8' 12' 15' <br /> On Slab On Slab 9'-6" 0 8'-2" B 7'-1" 8 6'4" B 5'-8" B 5'-2" B 4'-9" B 0-4" A 4'-l" B 3'-9" B 3'-6" 8 <br /> 0.042"x3"x8" MU76 8'-6" A 18 24 27 28 7'-8" B 18 23 26 28 7'-1" B 19 23 25 27 6'-7" B - 19 23 25 26 6'-1" C 19 22 25 26 5'-9" C 19 22 24 26 5'4" C 19 21 24 25 5'4" C 20 21 24 25 4'-9" C 20 22 24 25 4'-6" C 20 22 24 26 4'4" C 20 22 25 26 <br /> Double 3"x8" MU113 12'-10" C 21 27 30 31 11'-9" D 21 26 29 31 10'-10" D 21 26 28 30 10'-3" D 22 25 28 30 9'-7" D 22 25 28 29 9,1" D 22 24 27 29 8'-7" D 23 24 27 28 8'-2" D 23 24 26 28 7-9" D 23 24 26 28 7'-5" D 23 23 26 27 7'-1" D 23 23 26 27 <br /> Double 2"x6.5" MU113 11'-5" C 20 25 27 29 10'-6" C 20 24 27 28 9'-9" C 21 24 26 28 9'-2" D 21 23 26 27 B'-B" D 21 23 26 27 8'-2" D 22 23 25 27 7'9" 0 22 22 25 26 7'-5" D 22 22 25 26 7-1" D 22 22 24 26 6'-10" D 23 22 24 26 6'-7" 0 23 22 25 26 <br /> 16 G Steel C MU78 14'-10" D 22 28 31 33 13'-3" D 22 27 30 32 12'-1" D 22 26 29 31 10'-11" D 22 26 28 30 9'-10" D 22 25 28 29 8'-11" D 22 24 27 29 8'-2" D 22 24 26 28 7'-6" D 22 23 26 27 7'-0" D 22 23 25 27 6'-6" D 22 22 25 26 6'-1" D 22 22 25 26 <br /> 14 G Steel C MU78 17'-9" D 23 29 32 34 16'-0" D 23 28 31 33 14'-7" D 24 28 31 32 13'-7" D 24 27 30 32 12'-7" D 24 27 29 31 11'-8" D 24 26 29 31 11'-0" 0 25 26 28 30 10'-2" D 25 25 28 30 9'-5" D 25 25 27 29 8'-10" D 25 24 27 29 8'-3" D 25 24 26 28 <br /> 12 G Steel C MU78 24'-7" E 26 32 35 37 22'-11" E 26 31 34 36 21'-1" E 27 30 34 36 19'-9" E 27 30 33 35 18'-6" E 28 29 32 34 `17'4" G 28 29 32 34 16'9" G 28 28 32 33 15'-7" G 28 28 31 33 14'-10" G 29 28 31 33 14'-1" G 29 27 30 32 13'-6" H 29 27 30 32 <br /> Double 16 G Steel C MU114 25'-7" E 26 32 35 37 24'-3" E 27 31 35 37 23'-3" F 28 31 34 36 22'-4" G 28 31 34 36 21'-7" H 29 30 34 36 20'-9" H 30 30 33 35 19'9" H 30 30 33 35 18'10" H 30 29 33 35 18'-1" H 31 29 32 34 17-5" I 31 29 32 34 16'-9" I 31 29 32 34 <br /> Double 14 G Steel C MU114 27'-3" E 26 32 36 38 25'-11" E 27 32 35 37 24'-9" G 28 32 35 37 23'-10" H 29 31 35 37 23'-0" H 30 31 34 36 22'-3" H 30 31 34 36 21'-8" I 31 31 34 36 21,1" I 31 30 34 36 20'-7" I 32 30 33 35 19'-11" I 32 30 33 35 19'-3" I 33 30 33 35 <br /> Double 12 G Steel C MU114 31'-0" F 28 33 37 39 29'-5" G 29 33 37 39 28'-2" H 29 33 36 38 27'-1" H 30 32 36 38 26'-2" I 31 32 35 38 25'-4" I 32 32 35 37 24'-7" I 32 32 35 37 24'-0" 1 33 31 35 37 23'-5" 1 33 31 34 37 22'-10" 1 34 31 34 36 22'-5" 1 34 31 34 36 <br /> Steel Lockseam MU89 8'-7" 8 18 19 21 22 7'-10" 6 18 18 20 22 7-2" B 19 19 21 22 6'-9" C 19 19 21 23 6'-3" C 19 20 22 23 _5'41" C 19 20 23 24 5'-7" C 20 21 23 24 5'-3" C 20 21 24 25 5'-0" C 20 22 24 25 4'-9" C 20 22 24 26 4'-6" C 20 22 25 26 <br /> 0.120"x3x3 Alum MU96 9'-0" B 18 19 21 22 8'-7" C 19 19 21 22 8'-3" C 20 19 21 22 7'-11" C 20 19 21 23 `7'-8" C 21 20 22 23 7'-5" C 21 20 23 24 7'-2" D 21 21 23 24 7'-0" D 22 21 24 25 6'-10" D 22 22 24 25 6'-8" D 22 22 24 26 6'-6" D 23 22 25 26 <br /> 0.120"x4x4 Alum MUSO 12'-2" C 20 22 24 26 11'-7" C 21 22 24 26 11'-1" D 22 22 24 25 10-8" D 22 21 24 25 10'-3" D 23 21 23 25 10'-0" D 23 21 23 25 9'-8" D 24 21 23 24 9'-5" D 24 21 24 25 9'-2" D 24 22 24 25 9'-0" D 25 22 24 26 8'-10" E 25 22 25 26 <br /> DBL Steel lockseam MU120 12'-2" C 20 21 23 24 11'-7" C 21 20 22 24 11'-1" D 22 20 22 24 10'-8" D 22 20 22 23 10'-3" D 23 20 22 23 9'-11" D 23 20 23 24 9'-8" D 24 21 23 24 9'S" D 24 21 24 25 9'-1" D 24 22 24 25 8'-10" D 25 22 24 26 8'-6" D 25 22 25 26 <br /> D810.120"x3x3 Alum MU120 11'-5" C 20 20 22 24 10'-10" C 20 20 22 23 10'4" 0 21 20 22 23 10'-0" D 22 20 22 23 9'-7" D 22 20 22 23 9'-4" D 23 20 23 24 9'-1" D 23 21 23 24 8'-10" D 23 21 24 25 8'-7" D 24 22 24 25 8'-5" D 24 22 24 26 8'-3" D 25 22 25 26 <br /> OBL0.120"x4x4 Alum MU120 15'-4" D 22 23 26 27 14'-7" D 23 23 26 27 14'-0" D 23 23 25 27 13'-5" D 24 23 25 27 13'-0" D 24 22 25 26 12'-7" D 25 22 25 26 12,3" E 25 22 24 26 11'-11" E 26 22 24 26 11'-7" E 26 22 24 26 11'-4" E 27 22 24 26 11'-1" E 27 22 25 26 <br /> Samson Beam MU99 12'-2" C 20 24 27 28 11'-7" C 21 24 26 28 10'-10" D 21 23 26 28 10'-2" D 22 23 26 27 9'-7" D 22 23 25 27 9'-0" D 22 22 25 26 8,6" D 23 22 24 26 8'-1" D 23 22 24 26 7'-8" D 23 22 24 25 7'-4" D 23 22 24 26 7'-0" D 23 22 25 26 <br /> 3.5"x3"I beam MU65 9'-9" B 19 20 22 24 9'-3" C 19 20 22 23 8'-10" C 20 20 22 23 8'-6" C 21 19 22 23 8'-3" D 21 20 22 23 8'-0" D 21 20 23 24 7'-9" D 22 21 23 24 7'-7" D 22 21 24 25 7'4" D 23 22 24 25 7-2" D 23 22 24 26 7-0" D 23 22 25 26 <br /> 4"x3"I beam MU56 11'-0" C 20 22 24 25 10'-5" C 20 21 24 25 10'-0" C 21 21 23 25 9'-7" D 21 21 23 24 9,3" 0 22 21 23 24 8'-9" D 22 20 23 24 8'-2" 0 22 21 23 24 7'8" 0 22 21 24 25 7-3" D 23 22 24 25 6'-11" D 23 22 24 26 6'-7" D 23 22 25 26 <br /> 5"53"I beam MU57 13'4" C 21 24 27 28 12'-8" D 22 24 26 28 12'-1" D 22 23 26 27 11'-8" D 23 23 26 27 11'-3" D 23 23 25 27 _10'-8" D 24 23 25 27 10'-0" D 24 22 25 26 9'-5" D 24 22 24 26 8'-11" D 24 22 24 25 8'-5" 0 24 22 24 26 8'-0" D 24 22 25 26 <br /> 5"x4.11"I beam MU65 14'-7" D 21 24 27 29 13'-10" D 22 24 27 28 13'-3" D 23 24 26 28 12'-9" D 23 24 26 28 12'-3" D 24 23 26 28 1111" D 25 23 26 27 11'-7" E 25 23 26 27 11,3" E 25 23 25 27 10'-9" E 26 23 25 27 10'-3" E 26 22 25 26 9'-9" E 26 22 25 26 <br /> 7"x4"!beam MU58 19'-3" 0 24 29 32 34 18'-3" D 24 28 31 33 17'-6" E 25 28 31 33 16'-10" E 26 28 31 32 16'-3" E 26 27 30 32 15'-9" E 27 27 30 32 15'-4" E 27 27 30 32 14'-11" G 28 27 30 31 14'-6" G 28 27 30 31 14'-1" G 29 26 29 31 13'-5" H 29 26 29 31 <br /> 7n5.86"Ibeam MU63 20'4" D 24 29 32 34 19'-3" D 25 29 32 34 18'-5" E 26 28 31 33 17-6" E 26 28 31 33 16'-2" E 26 27 30 32 -15'-0" E 27 27 30 32 14'-0" E 27 26 29 31 13'-1" E 27 26 29 30 12'4" E 27 26 28 30 11'-8" E 27 25 28 30 11'-0" E 27 25 28 29 <br /> 10"x5.86"I beam MU62 31'-1" F 28 35 39 42 29'-6" G 29 35 39 41 28'-3" H 29 35 38 41 27'-2" H 30 34 38 40 26'-3" I 31 34 38 40 25'-5" 1 32 34 37 39 24,8" 1 32 33 37 39 20-1" 1 33 33 37 39 23'-6" 1 33 33 37 39 22'-11" 1 34 33 36 38 22'4" J 34 33 36 38 <br /> 7"x55"I beam MU59 19'-11" D 24 29 32 34 18'-11" D 25 29 32 33 18'-1" E 25 28 31 33 17'-5" E 26 28 31 33 16'-10" E 27 28 31 32 16'4" E 27 27 30 32 15'40" G 28 27 30 32 15'-5" G 28 27 30 32 15'-0" G 29 27 30 32 14'-5" H 29 27 30 31 13'-9" H 29 26 29 31 <br /> 10"x55"1 beam MU60 28'41" E 27 35 39 41 27'-6" G 28 34 38 40 26'4" G 29 34 38 40 25'4" H 30 34 37 39 `24'-5" H 30 33 37 39 23'-8" 1 31 33 37 39 23,0" I 31 33 36 38 22'5" I 32 33 36 38 21'-10" I 33 32 36 38 21'4" 1 33 32 36 38 20'-11" 1 34 32 35 38 <br /> 5"RF Fascia MU16 6'-9" A 17 20 22 24 6'-0" A 17 20 22 23 5'-6" A 17 19 21 22 5'-1" A 17 19 21 23 4'-8" A 17 20 22 23 4'-4" A 18 20 23 24 4'4" A 18 21 23 24 3'-10" A 18 21 24 25 3'-7" A 18 22 24 25 3'-5" B 18 22 24 26 3'-3" 8 18 22 25 26 <br /> 6.5"RF Fascia MU15 7'-3" A 17 22 24 26 6'-6" A 17 21 24 25 5'-11" A 17 21 23 24 5'-5" A 18 20 23 24 5'-0" A 18 20 22 23 4'-8" A 18 20 23 24 4'4" B 18 21 23 24 4'-0" B 18 21 24 25 3'-9" B 18 22 24 25 `3'-7" 8 18 22 24 26 3'-5" B 18 22 25 26 <br /> 6"Extruded Fascia MU31 10'-6" C 19 24 26 28 9'-5" C 20 23 25 27 8'-7" C 20 22 25 26 8'-0" C 20 22 24 26 7'-5" C 20 22 24 25 6'-11" C 20 21 24 25 6'-6" C 21 21 23 25 6'-1" C 21 21 24 25 5'-9" C 21 22 24 25 5'-5" D 21 22 24 26 5'-2" D 21 22 25 26 <br /> Samson Fascia MU20 10'-11" C 19 23 26 27 9'41" C 20 23 25 27 9'-1" C 20 22 25 26 8'-6" C 21 22 24 26 8'-0" C 21 22 24 25 7'-6" D 21 21 24 25 7'-0" D 21 21 23 25 6'-8" D 21 21 24 25 6'4" D 22 22 24 25 6'-0" D 22 22 24 26 5'-9" D 22 22 25 26 <br /> 5"and 5.5"Ext Fascia MUO7 8'-0" A 18 22 24 25 7'-2" A 18 21 23 25 6'-7" B 18 20 23 24 6'-1" B 18 20 22 24 5'-8" B 19 20 22 23 5'-3" 0 19 20 23 24 4'-11" B 19 21 23 24 4'-7" C 19 21 24 25 4'4" C 19 22 24 25 4'-1" C 19 22 24 26 3'-11" C 19 22 25 26 <br /> 4.5"Ex Alum Fascia MU32 7-1" A 17 20 23 24 6'4" A 17 20 22 23 5'-9" A 17 19 21 23 5'4" A 18 19 21 23 4'-11" A 18 20 22 23 4'-7" A 18 20 23 24 4'-3" B 18 21 23 24 _4'-0" B 18 21 24 25 3'9" B 18 22 24 25 3'-7" B 18 22 24 26 3'-5" 8 18 22 25 26 <br /> 6"RF Panda MU29 4'4" A 14 19 21 22 3'-10" A 14 18 20 21 3'4" A 15 19 21 22 3'-1" A 15 19 21 23 2'-9" A 15 20 22 23 `2'-6" A 15 20 23 24 2'4" A 15 21 23 24 2'-2" A 15 21 24 25 2'-0" A 15 22 24 25 1'40" A 15 22 24 26 1'-9" A 15 22 25 26 <br /> 5"Magnum Gutter MU36 8'-6" A 18 21 24 25 7-6" 8 18 21 23 24 6'-8" B 18 20 22 24 6'-1" B 18 20 22 23 5'-6" B 18 20 22 23 5'-1" B 18 20 23 24 4'-8" 8.-._,_ 19 21 23 24 4'-4" B 19 21 24 25 4'-0" B 19 22 24 25 3'-9" B 19 22 24 26 3'-6" B 19 22 25 26 <br /> 6"Magnum Gutter-.- -°MU37-:'12_-10" C 21 25 28 29 12'-1" D 21 24 27 29 11'-3" D 22 24 27 28 10'-7" D 22 24 26 28 9'-11" D 22 23 26 27 9'-5" 0 23 23 25 27 8'-11" CI--••.923 23 25 27 8'-6" D 23 22 25 26 8'-1" D 23 22 25 26 7-9" D 24 22 24 26 7-5" D 24 22 25 26 <br /> 6"Smooth Gutter MU38 10'-5" C 19 24 26 28 9'-8" C 20 23 26 27 9'-2" C 20 23 25 27 8'-9" C 21 23 25 26 8'3" D 21 22 25 26 7'-9" D 21 22 24 26 7'-5" D 22 22 24 25 7'-1" D 22 21 24 25 6'-9" D 22 22 24 25 0-6" D 22 22 24 26 0-3" 0 22 22 25 26 <br /> Table 5.25 tub Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) sob Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) trib Min Uplift Footing(in) <br /> Post Footing Max Post Length Post Footing Max Post Length Post Footing Max Post Length Post Footing Max Post Length Post Footing Max Past Length Post Footing Max Post Length Post Footing Max Post Length Post Footing Max Post Length Post Footing Max Post Length Post Footing Max Post Length <br /> H eader Detail 8.5' Type (in) 8' 12' 15' 9' Type (in) 8' 12' 15' 9.5' Type linl 8' 12' 15' 10' Type (in) 8' 12' 15' 10.5' Type (in) 8' 12' 15' 11' Type fin) 8' 12' 15' 11.5' Type (in) 8' 12' 15' 12' Type (in) 8' 12' 15' 13' Type (in) 8' 12' 15' 14' Type (In) 8' 12' 15' <br /> On Slab On Slab 3'4" B 3,2" 8 3'-0" B 2'-10" B 7-8" B 2.7" B 2'-5" 0 2'4" B 2'-2" B <br /> 0.042"x3"x8" MU76 4'-1" C 20 23 25 27 3'-11" C 20 23 26 27 3'-9" C 26 23 26 28 3'-7" C 20 24 26 28 3'-5" C 26 24 27 28 3'4" C 20 24 27 29 3'-2" C 20 25 27 29 3'-1" C 20 25 28 29 2'-10" C 20 25 28 30 2'-8" C 20 26 29 30 <br /> Double3"x8" MU113 6'-10" D 24 23 25 27 6'-7" D 24 23 26 27 6'4" D 31 23 26 28 6'-1" D 24 24 26 28 5'-11" D 32 24 27 28 5'-8" D 24 24 27 29 5'-6" D 24 25 27 29 $'4" 0 24 25 28 29 5'-1" D 25 25 28 30 4'-9" D 25 26 29 30 <br /> Double 2"x6.5" MU113 6'-4" D 23 23 25 27 6'-1" 0 23 23 26 27 5'-11" D 30 23 26 28 5'-8" D 23 24 26 28 5'-6" D 31 24 27 28 5'-4" D 24 24 27 29 5"2" 0 24 25 27 29 _5'-1" 0 24 25 28 29 4'-10" D 24 25 28 30 4'-7" D 24 26 29 30 <br /> 16 G Steel C MU78 5'-9" D 22 23 25 27 5'-5" D 22 23 26 27 5'-2" D 29 23 26 28 4'-10" D 22 24 26 28 4'-8" D 29 24 27 28 4'-5" D 22 24 27 29 4'9" D 22 25 27 29 4'-l" D 22 25 28 29 3'-9" D 22 25 28 30 3'-6" D 22 26 29 30 <br /> 14 G Steel C MU78 7'-9" D 25 24 26 28 7'4" D 25 23 26 27 6'-11" D 32 23 26 28 6'-7" D 25 24 26 28 6'-3" D 32 24 27 28 6'-0" D 25 24 27 29 5'-9" D 25 25 27 29 5'-6" D 25 25 28 29 5'4" D 25 25 28 30 4'-9" D 25 26 29 30 <br /> 12 G Steel C MU78 13'-0" H 29 27 30 31 12'-6" H 29 27 29 31 12'-0" H 39 26 29 31 11'-7" H 30 26 29 31 11'-2" H 39 26 29 30 10'-10" H 30 26 28 30 10'-6" H 30 25 28 30 10'-2" H 30 25 28 30 9'-8" H 31 25 28 30 9'-2" I 31 26 29 30 <br /> Double 16 G Steel C MU114 16'-2" I 31 28 31 33 15'-8" I 32 28 31 33 15'-2" I 42 28 31 33 14'-8" I 32 28 31 32 14'-3" I 42 27 30 32 13'-10" I 33 27 30 32 13'-6" 1 33 27 30 32 13'-2" 1 33 27 30 32 12'-7" 1 33 27 29 31 12'-0" 1 34 26 29 31 <br /> Double 14 G Steel C MU114 18'-8" 1 33 29 33 34 18'-1" 1 33 29 32 34 17'-7" 1 44 29 32 34 17'-1" 1 34 29 32 34 16'-8" J 44 29 32 33 16'-3" J 34 28 31 33 15'-10" 1 35 28 31 33 15'-5" 1 35 28 31 33 14'-30" 1 35 28 31 33 14'-3" 1 36 27 30 32 <br /> Double 12 G Steel C MU114 21'-11" 1 35 31 34 36 21'-6" 1 35 30 34 36 21'-2" 1 47 30 34 36 20'-9" 1 36 30 33 35 20'-5" 1 48 30 33 35 20'-2" 1 37 30 33 35 19'-10" 1 37 30 33 35 19'-6" K 38 30 33 35 10-9" K 38 29 33 35 18'-1" K 39 29 32 34 <br /> Steel Lockseam MU89 4'4" C 20 23 25 27 4'-2" C 20 23 26 27 4'-0" C 27 23 26 28 3'-10" C 21 24 26 28 3'-9" C 27 24 27 28 3'-7" C 21 24 27 29 3'-6" C 21 25 27 29 3'-5" D 21 25 28 29 _3'-2" D 21 25 28 30 3'-0" D 21 26 29 30 <br /> 0.120"x3x3 Alum MU96 6'-5" D 23 23 25 27 6'-3" D 23 23 26 27 6'-2" D 31 23 26 28 6'-1" D 24 24 26 28 5'-11" D 32 24 27 28 5'-10" D 24 24 27 29 5'-9" D 25 25 27 29 5'-8" D 25 25 28 29 5'-7" E 25 25 28 30 5'-5" E 26 26 29 30 <br /> 0.120"x4x4 Alum MU50 8'-7" E 26 23 25 27 8'-6" E 26 23 26 27 8'4" E 34 23 26 28 8'-2" E 26 24 26 28 8'-0" E 35 24 27 28 7'-11" E 27 24 27 29 7-10" E 27 25 27 29 7,8" F 28 25 28 29 7-5" G 28 25 28 30 7,1" G 28 26 29 30 <br /> DBL Steel Lockseam MU120 8'-3" E 25 23 25 27 8'-0" E 25 23 26 27 7-10" E 33 23 26 28 7'-7" E 26 24 26 28 7-5" E 34 24 27 28 7-3" E 26 24 27 29 7'4" E 26 25 27 29 6'-11" E 27 25 28 29 6'-8" E 27 25 28 30 6'-5" E 27 26 29 30 <br /> D B1.0.120"u3x3 Alum MU120 8'-1" D 25 23 25 27 7'-11" E 25 23 26 27 7-9" E 33 23 26 28 7-8" E 26 24 26 28 7'-6" E 34 24 27 28 7'-5" E 26 24 27 29 7'-3" E 27 25 27 29 7'-2" E 27 25 28 29 7,0" E 27 25 28 30 6'-10" G 28 26 29 30 <br /> DBL 0.120"x4x4 Alum MU120 10'-11" F 28 23 25 27 10'-8" G 28 23 26 27 10'-6" G 37 23 26 28 104" G 29 24 26 28 10'-2" H 38 24 27 28 10'-0" H 29 24 27 29 9'-10" H 29 25 27 29 9'-8" H 30 25 28 29 9'-5" H 30 25 28 30 9'-3" I 31 26 29 30 <br /> Samson Beam MU99 6'-9" D 24 23 25 27 6'-6" D 24 23 26 27 6'-3" D 31 23 26 28 6'-0" D 24 24 26 28 5'-10" D 31 24 27 28 5'-8" 0 24 24 27 29 S'-6" D 24 25 27 29 5'4" D 24 25 28 29 5'-0" D 25 25 28 30 4'-9" D 25 26 29 30 <br /> 3.5"03"I beam MUGS 6'-11" D 24 23 25 27 6'-9" D 24 23 26 27 6'-6" D 32 23 26 28 6'-3" D 24 24 26 28 6'-1" D 32 24 27 28 5'40" D 24 24 27 29 5'-8" D 25 25 27 29 S'-6" D 25 25 28 29 5'-2" D 25 25 28 30 4'-11" D 25 26 29 30 <br /> 4"x3"I beam MU56 6'-3" D 23 23 25 27 5'-11" D 23 23 26 27 5'-8" D 30 23 26 28 5'-5" D 23 24 26 28 5'-3" D 30 24 27 28 5'-0" D 23 24 27 29 4'40" D 23 25 27 29 4'-8" D 23 25 28 29 4'-5" D 23 25 28 30 4'-1" D 24 26 29 30 <br /> 5"0.3"I beam MU57 7-8" D 25 23 25 27 7'4" 0 25 23 26 27 7-0" D 32 23 26 28 6'-9" D 25 24 26 28 6'-5" D 32 24 27 28 6'9" D 25 24 27 29 6'-0" D 25 25 27 29 5'-9" E 25 25 28 29 5'-5" E 25 25 28 30 5'-1" E 25 26 29 30 <br /> 5"04.11"I beam MU65 9'-3" E 26 23 25 27_8'-11" E 26 23 26 27 8'-6" E 26 23 26 28 8'-2" E 26 24 26 28 7'-11" E 27 24 27 28 7-7" E 27 24 27 29 7'4" E 27 25 27 29 7'-1" E 27 25 28 29 6'-8" E 27 25 28 30 6'-3" E 27 26 29 30 <br /> 7"x4"I beam MU58 12'-10" H 29 26 29 30 12'4" H 29 26 28 30 11'-10" H 29 25 28 30 11'-5" H 30 25 28 29 11'-0" H 30 25 28 29 10'-7" H 30 25 27 29 10'-3" H 30 25 27 29 9'-11" H 30 25 28 29 9'-5" H 30 25 28 30 8'-10" H 30 26 29 30 <br /> 7"5.86"I beam MU63 10'-6" E 27 25 27 29 10,0" E 27 24 27 28 9'6" E 27 24 27 28 9'-1" E 27 24 26 28 8'-9" E 27 24 27 28 8'-5" F 28 24 27 29 8'-1" F 28 25 27 29 7'-9" F 28 25 28 29 7'-3" G 28 25 28 30 6'-9" G 28 26 29 30 <br /> 10°05.86.'1 beam MU62 21'-5" 1 34 32 36 38 20'-6" 1 35 32 35 37 _19'-8" J 35 32 35 37 18'-11" J 35 31 35 37 18'-3" 1 35 31 34 36 17'-7" 1 35 31 34 36 17'-0" 1 35 30 34 36 16'-5" J 35 30 33 35 15'-6" 1 36 30 33 35 14'-7" 1 36 29 32 34 <br /> 7"x5.5"Ibeam M115913'-2" H 29 26 29 31 12'-8" H 29 26 29 30 12'-2" H 30 25 28 30 11'-8" H 30 25 28 30 11'-3" H 30 25 28 29 10'-10" H 30 25 27 29 10'-6" H 30 25 27 29 10'-2" H 30 25 28 29_9'-7" H 30 25 28 30 9'-0" H 31 26 29 30 <br /> 10"x55"!beam MU60 20'-2" 1 34 32 35 37 19'4" 1 34 31 35 37 18'-8" 1 34 31 34 36 17'-11" 1 34 31 34 36 17-4" 1 34 31 34 36 16'-9" 1 35 30 34 35 16'-2" 1 35 30 33 35 15'-8" 1 35 30 33 35 14'-10" 1 35 29 33 34 14'-0" 1 35 29 32 34 <br /> 5"RF Fascia MU16 3'-1" B 18 23 25 27 2'-11" B 18 23 26 27 2'-10" B 18 23 26 28 2'-8" B 18 24 26 28 2'-7" B 18 24 27 28 2'-5" B 18 24 27 29 2'4" B 18 25 27 29 2'-3" B 18 25 28 29 2'-2" B 19 25 28 30 2'-0" B 19 26 29 30 <br /> • 6.5"RF Fascia MU15 3'-2" B 18 23 25 27 3'-1" B 18 23 26 27 2'-11" B 18 23 26 28 2'-9" B 19 24 26 28 2'-8" B 19 24 27 28 2'-6" B 19 24 27 29 7-5" 8 19 25 27 29 2'4" B 19 25 28 29 2'-2" B 19 25 28 30 2'-0" B 19 26 29 30 <br /> 6"Extruded Fasda MU31 4'-11" D 21 23 25 27 4'-8" D 21 23 26 27 4'-6" 0 21 23 26 28 4'-3" D 21 24 26 28 4'-1" If 21 24 27 28 3'-11" D 21 24 27 29 3'-10" D 22 25 27 29 3,8" D 22 25 28 29 3'9" 0 22 25 28 30 3'-3" D 22 26 29 30 <br /> Samson Fascia MU20 5'-6" D 22 23 25 27 5'-3" D 22 23 26 27 5'-0" D 22 23 26 28 4'-10" D 22 24 26 28 4'-8" D 22 24 27 28 4'-6" D 22 24 27 29 4'4" D 22 25 27 29 4'-3" D 23 25 28 29 4'-0" D 23 25 28 30 3'-9" D 23 26 29 30 <br /> 5"and 55"Ext Fascia MUO7 3'-8" C 19 23 25 27 3'-6" C 19 23 26 27 3'-4" C 19 23 26 28 3'-3" C 19 24 26 28 3'.' C 19 24 27 28 3'-0" C 20 24 27 29-2'-10" C 20 25 27 29 2'-9" C 20 25 28 29 `2'-7" C 20 25 28 30 2'-5" C 20 26 29 30 <br /> 4.5"Ex Alum Fascia MU32 3'-3" 0 18 23 25 27 3'-1" B 18 23 26 27 2'-11" B 19 23 26 28 `2'- " B 19 24 26 28 -8" 6 19 24 27 28 -2'-7" B 19 24 27 29 2'-6" B 19 25 27 29 2'-S" B 19 25 28 29 7-3" B 19 25 28 30 2'-1" B 19 26 29 30 <br /> 6"RF Fascia MU29 1'-8" A 15 23 25 27 1'-7" A 15 23 26 27 1'-6" A 15 23 26 28 1'- ' A 15 24 26 28 r 1'-4" A 15 24 27 28 1'-3" A 15 24 27 29 1'-3" A 15 25 27 29 1'-2" A 15 25 28 29 1'-1" A 15 25 28 30 1'-0" A 15 26 29 30 <br /> 5"Magnum Gutter MU36 3'4" B 19 23 25 27 3'-2" B 19 23 26 27 3'-0" B 19 23 26 28 2'-1' 8 19 24 26 2: 2'-8" B 9 24 27 28 2'-7" B 19 24 27 29 2'-6" 8 19 25 27 29 2'4" 8 19 25 28 29 2'-2" B 19 25 28 30 2'-0" 8 19 26 29 30 <br /> 6"Magnum Gutter MU37 7'-2" D 24 23 25 27 6'-11" D 24 23 26 27 6'-8" D 24 23 • 28 6'-3 D 24 24 26 : 6'-3" D '5 24 27 28 6'-1" D 25 24 27 29 5'41" D 25 25 27 29 5,9" D 25 25 28 29 5'-5" E 25 25 28 30 5'-2" E 25 26 29 30 <br /> 6"Smooth Gutter MU38 6'-0" D 23 23 25 27 5'-9" D 23 23 26 . ' 0 23 23 • 28 5'-1 D 23 24 26 8 5'-3" D '3 24 27 28 5'-1" D 23 24 27 29 4'-11" D 23 25 27 29 4'40" D 24 25 28 29 `4'-7" D 24 25 28 30 4'-4" D 24 26 29 30 <br /> Four Seasons Building Products Carl Putnam,P.E. `�Q`,'0 jHOFFss <br /> 5005 Veteran's Memorial Hwy 3441 Ivylink Place <br /> Holbrook,NY 11741 Lynchburg,VA 24503 >. c1GIN /0 ANAL �1„ �, r'Ur�; <br /> (631)563-4000 (434)384-2514 w� E .A. 2 ��, i-tj <br /> cadputnamecomcastmet 72580P \ 9f p `� SNS, t. w�sEr/f. <br /> Q�` • ^,- .� <br /> \\ d <br /> •-1 t 211 'trim, f\� <br /> OREG8N 7�y <br /> v 3 <br /> .0 )'3i, ,00t A 0f ,?FSI t t Feb 14 2017 ( 'a ,,,?) <br /> SRC PU P OF0 �5.,s, vAL�`"c,\ <br /> Four Seasons ICC ESR 1953(2015 IBC) 1/26/2017 EXPIRES:DEC 31,2►18 'age 75 of 98 <br />