My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
917 112TH ST SE Geotech Report 2022-10-25
>
Address Records
>
112TH ST SE
>
917
>
Geotech Report
>
917 112TH ST SE Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 11:39:22 AM
Creation date
8/20/2019 11:18:10 AM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SE
Street Number
917
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Habitat for Humanity of Snohomish County ES-5168 <br /> April 26, 2017 Page 8 <br /> Retaining walls should be backfilled with free-draining material that extends along the height of <br /> the wall, and a distance of at least 18 inches behind the wall. The upper one foot of the wall <br /> backfill can consist of a less permeable soil, if desired. A perforated drain pipe should be <br /> placed along the base of the wall, and connected to an approved discharge location. A typical <br /> retaining wall drainage detail is provided on Plate 3. <br /> Excavations and Slopes <br /> The Federal Occupation Safety and Health Administration (OSHA) and the Washington <br /> Industrial Safety and Health Act (WISHA) provide soil classification in terms of temporary slope <br /> inclinations. Based on the soil conditions encountered at the test pit locations, the weathered <br /> native soils encountered in the upper approximately three to four feet at the test pit locations <br /> and where fill and/or groundwater seepage is exposed are classified as Type C by <br /> OSHA/WISHA. Temporary slopes over four feet in height in Type C soils must be sloped no <br /> steeper than 1.5H:1V (Horizontal:Vertical). Dense to very dense unweathered native glacial till <br /> soils encountered below about three to four feet where no groundwater seepage is exposed <br /> would be classified as Type A by OSHA/WISHA. Temporary slopes over four feet in height in <br /> Type A soils must be sloped no steeper than 0.75H:1V. The presence of perched groundwater <br /> may cause caving of the temporary slopes due to hydrostatic pressure. ESNW should observe <br /> site excavations to confirm the soil type and allowable slope inclination are appropriate for the <br /> soil exposed by the excavation. If the recommended temporary slope inclination cannot be <br /> achieved, temporary shoring may be necessary to support excavations. <br /> Permanent slopes should maintain a gradient of 2H:1V, or flatter, and should be planted with <br /> vegetation to enhance stability and to minimize erosion. A representative of ESNW should <br /> observe temporary and permanent slopes to confirm the slope inclinations are suitable for the <br /> exposed soil conditions, and to provide additional excavation and slope recommendations, as <br /> necessary. <br /> Seismic Desgn <br /> The 2015 International Building Code recognizes the American Society of Civil Engineers <br /> (ASCE) for seismic site class definitions. In accordance with Table 20.3-1 of the ASCE <br /> Minimum Design Loads for Buildings and Other Structures manual, Site Class D should be <br /> used for design. <br /> The referenced liquefaction susceptibility map indicates the subject site maintains very low <br /> liquefaction susceptibility. Liquefaction is a phenomenon where saturated and loose soils <br /> suddenly lose internal strength and behave as a fluid. This behavior is in response to <br /> increased pore water pressures resulting from an earthquake or other intense ground shaking.; <br /> In our opinion, site susceptibility to liquefaction may be considered negligible. The relatively <br /> consistent densities of the native soils and the absence of a uniformly established, shallow <br /> groundwater table were the primary bases for this consideration. <br /> Earth Solutions NW,LLC <br />
The URL can be used to link to this page
Your browser does not support the video tag.