Laserfiche WebLink
Y + <br /> net intemet connection. Requires compatible Teldat Visorslarm 4.0"(10.16 cm.)box.Includes plastic cover plate and end-of-line <br /> Central Station Receiver.Can use DHCP or static IR (See data resistor.Module may be configured for either a Style B(Class B) <br /> sheet df-52424 for more information.) or Style D(Class A)IDC. <br /> IPBRKT:Mounting kit for IPDACT2/2UD in common enclosure. MDF-300: Dual Monitor Module. Same as MMF-300 except it <br /> IPSPLT:Y adaptor option allows connection of both panel dialer provides two Style B(Class B)only IDC5. <br /> outputs to one IPDACT.2/2UD cable input. MMF-301: Miniature version of MMF-300. Excludes LED and <br /> AC-TRMBLK:AC Terminal Block mounts to a metal bracket,in Style D option.Connects with wire pigtails.May mount in device <br /> turn,mounts to the FACP chassis.Use AC-TRMBLK when wire backbox. <br /> nuts are not allowed for AC connections to the transformer. MMF-302A:Similar to MMF-300A.Addressable Monitor Module <br /> MODULES for one zone of conventional two-wire detectors.Requires reset- <br /> OPTIONALtable 24 VDC power. Refer to the Device Compatibility Docu- <br /> 4XTMF Reverse Polarity Transmitter Module: Provides a ment for listed compatible devices and quantity limitation. <br /> supervised output for local energy municipal box transmitter, CMF-300:Addressable Control Module for one Style Y2(Class <br /> alarm and trouble.Includes a disable switch and disable trouble B/A) zone of supervised polarized Notification Appliances. <br /> LED. Mounts directly to a 4.0" (10.16 cm.)electrical box. Notification <br /> ANN-SEC: Optional secondary ANN-BUS interface module. Appliance Circuit option requires external 24 VDC to power noti- <br /> Note:Used only with firmware 3.0 or higher. fication appliances. <br /> COMPATIBLE ANNUNCIATORS CRF-300: Addressable relay module containing two isolated <br /> sets of Form-C contacts, which operate as a DPDT switch. <br /> ANN-80(-W): Remote LCD annunciator mimics the information Mounts directly to a 4.0" (10.16 cm.)box, surface mount using <br /> displayed on the FACP LCD display.Recommended wire type is the SMB500. <br /> un-shielded.(Basic model is red;order-W version for white;see BG-12LX:Addressable manual pull station with interface mod- <br /> DF-52417.) ule mounted inside. <br /> ANN-I/O: LED Driver Module provides connections to a user 1300:This module isolates the SLC loop from short circuit condi- <br /> supplied graphic annunciator. (See DF-52430.) tions(required for Style 6 or 7 operation). <br /> ANN-LED: Annunciator Module provides three LEDs for each SMB500: Used to mount all modules except the MMF-301 and <br /> zone: Alarm,Trouble, and Supervisory. Ships with red enclo- M301. <br /> sure.(See DF-60241.) <br /> ANN-BLED: Provides alarm (red) indicators for up to 30 input MMF-300-10:Ten-input monitor module.Mount one or two mod- <br /> zones or addressable points. (See DF-60241.) ules in a BB-2F cabinet(optional).Mount up to six modules on a <br /> CHS-6 chassis in a BB-6F cabinet. <br /> ANN-RLY: Relay Module provides 10 programmable Form-C MMF-302-6: Six-zone interface module.Mount one or two mod- <br /> relays. Can be mounted inside the cabinet.(See DF-52431.) ules in a BB-2F cabinet(optional).Mount up to six modules on a <br /> ANN-S/PG: Serial/Parallel Printer Gateway module provides a CHS-6 chassis in a BB-6F cabinet. <br /> connection for a serial or parallel printer.(See DF52429.) CMF-300-6:Six-circuit supervised control module.Mount one or <br /> ADDRESSABLE DEVICES two modules in a BB-2F cabinet(optional).Mount up to six mod- <br /> All feature a polling LED and rotary switches for addressing. ules on a CHS-6 chassis in a BB-6F cabinet. <br /> CP355: CRF-300.6: Six-relay control module (Form-C relays). Mount <br /> Addressable low-profile ionization smoke detector. <br /> one or two modules in a BB-2F cabinet(optional). Mount up to <br /> SD355:Addressable low-profile photoelectric smoke detector. six modules on a CHS-6 chassis in a BB-6F cabinet. <br /> SD355T: Addressable low-profile photoelectric smoke detector NOTE:For more information on Compatible Addressable Devices <br /> with thermal sensor. for use with the MS-9050UD,see the following data sheets(docu- <br /> SD355R: Remote test capable addressable photoelectric ment numbers):AD355(DF-52386),BG-12LX(DF-52013), CMF- <br /> smoke detector for use with DNR(W)duct detector housing. 300-6(DF-52365),CRF-300-6(DF-52374),CMF/CRF Series(DF- <br /> 52130), CP355(DF-52383), H355 Series (DF-52385), 1300(DF- <br /> H355:Fast-response,low-profile heat detector. 52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 <br /> H355R: Fast-response, low-profile heat detector with rate-of- (DF-52347), MMF-302-6 (DF-52356), SD355/SD355T (DF- <br /> rise option. 52384). <br /> H355HT:Fast-response,low-profile heat detector that activates ADDRESSABLE DEVICE ACCESSORIES <br /> at 190°F/88°C. End-of-LIne Resistor Assembly (R-47K and R-3.9K): The <br /> AD355: Low-profile, intelligent, "Adapt" multi-sensor detector 47k ohm assembly supervises the MMF-300, MDF-300, MMF- <br /> (B350LP base included). 301, and CMF-300 module circuits. The 3.9k ohm assembly <br /> BEAM355:Intelligent beam smoke detector. supervises the MMF-302 module circuit. These resistors are <br /> BEAM355S: Intelligent beam smoke detector with integral sen- included with each module. <br /> sitivity test. Power Supervision Relay: Supervises the power to 4-wire <br /> D355PL:InnovairFiex low-flow non-relay duct-detector housing; smoke detectors and notification appliances. <br /> includes SD355R. <br /> DNR: lnnovairFlex low-flow non-relay duct-detector housing. Wiring Requirements <br /> (Order SD355R separately.) While shielded wire is not required, it is recommended that all <br /> DNRW lnnovairFlex low-flow non-relay duct-detector housing, SLC wiring be twisted-pair to minimize the effects of electrical <br /> with NEMA-4 rating. Watertight.(Order SD355R separately.) interference.Refer to the panel manual for wiring details. <br /> MMF-300: Addressable Monitor Module for one zone of nor- <br /> mally-open dry-contact initiating devices. Mounts in standard <br /> OF-52418:E1•1/27/12—Page 3 of 4 <br />