ESICL <br /> E'rntunrlOh <br /> SERVICE Most Widely Accepted and Trusted <br /> awn <br /> ICC-ES Evaluation Report ESR-1289 <br /> l/ l Reissued October 2017 <br /> �,� Revised January 2018 <br /> I <br /> 0/f This report is subject to renewal October 2018. <br /> www.icc-es.orq ( 800 423-6587 (562) 699-0543 A Subsidiary of the International Code Council® <br /> DIVISI o N: t 9 00 00—FINISHES PS 2) of nonfire-resistance-rated or screw-attached <br /> Section: 0. 22 26—Suspension Systems gypsum wall board (complying with ASTM C36 or ASTM <br /> C1396) ceiling panels of fire-resistance-rated, interior roof <br /> REPORT HOLD -. and/or floor-ceiling assemblies. <br /> WORTHINGTON ARMSTRONG VENTURE(WAVE) The XL 7936 series ceiling system is designed for interior <br /> 101 LINDENWOOD DRIVE,SUITE 350 or exterior nonfire-resistance-rated roof-ceiling and/or <br /> MALVERN,PENNSYLVANIA 19355 floor-ceiling assemblies. For exterior ceilings without <br /> (610)722-1218 weather-exposed surfaces, as defined in IBC Section <br /> wtww.armstronq.com 2502, the system is designed for screw-attached gypsum <br /> jrameen@armstrongceilings.com sheathing (complying with ASTM C79 or ASTM C1396). <br /> For exterior weather-exposed surfaces, the system is <br /> EVALUATION SUBJECT: designed for screw-attached metal lath (complying with <br /> ASTM C847) with three coats of cement (Type I or II <br /> FIRE-RESISTANCE-RATED AND NONFIRE-RESISTANCE- Portland cement complying with ASTM C150) plaster <br /> RATED SUSPENDED CEILING SYSTEMS finish. <br /> 3.2 Components: <br /> ADDITIONAL LISTEE: <br /> 3.2.1 Main Runners: Main runners used in both the <br /> ARMSTRONG WORLD INDUSTRIES 8900 series ceiling systems and XL 7936 series ceiling <br /> POST OFFICE BOX 3001 systems are the 8900 (Drywall Stucco and Plaster System) <br /> LANCASTER,PENNSYLVANIA 17604 series main runners. All main runners are classified as <br /> heavy-duty in accordance with ASTM C635. The main <br /> 1.0 EVALUATION SCOPE runners have an inverted T-shape and double web. The <br /> Compliance with the followingcode: double web section is rotary-stitched together with a <br /> p knurled lower flange for screw penetration, and is <br /> • 2015, 2012, 2009 and 2006 International Building reverse-folded over for screw retention along the entire <br /> Code®(IBC) length of the bottom flange. The runners are cold-formed <br /> • 2013 Abu Dhabi International Building Code(ADIBC)t from ASTM A653, CS Type B steel, and have a hot <br /> dipped, galvanized G-40 coating for interior ceilings or a <br /> 'The ADIBC is based on the 2009 IBC.2009 IBC code sections referenced G-90 coating for exterior ceilings. Table 1 and Figure 1 <br /> in this report are the same sections in the ADIBC. <br /> specify the dimensions, lengths and allowable transverse <br /> Properties evaluated: loads. <br /> ■ Exterior and interior finish The HD 8906, HD89061IC and HD890610 main <br /> • Fire-resistance runners for fire-resistance-rated systems have an <br /> • Structural added end-coupling for temperature expansion relief, and <br /> additional routs for added cross-runner spacing to <br /> 2.0 USES accommodate field assembly of NEMA Type F lighting <br /> The suspended ceiling systems described in this report in nonfire-rated installations. <br /> are suspended or direct-hung, concealed framing, The SP-135 main runners for stucco systems are <br /> ceiling assemblies used in fire-resistance-rated and non-fire-resistance-rated systems. SP-135 main runner <br /> nonfire-resistance-rated construction for both exterior and rout spacing is designed for cross runner spacing of <br /> interior applications. 131/2 inches (343 mm) on center to accommodate stucco <br /> 3.0 DESCRIPTION lathing. <br /> 3.1 General: The main runner has lengths and routing that allow the <br /> The 8900 series ceiling system is designed for ceiling framing system to be assembled in the field without <br /> screw-attached wood panels(complying with DOC PS 1 or field-cutting or screw fastening. <br /> KV-ES Evaluation Reports are not 10 he construed as representing aesthetics or any other attributes not specifically addressed nor are they 10 he construed �;y� <br /> as an endorsement of the subject o1'the report ora recommendation for its use.There is no warranty by!('C Evaluation Service,LL(',express or implied,as lir /' <br /> to msf ruling or other matter in tens report or as to any prodiw1 covered by the report. I <br /> Copyright©2018 ICC Evaluation Service,LLC.All rights reserved. Pag�*j <br />