Design Build 5ervice5 , I nc. <br />Engineering & Gonstruction Management <br />28119 -120th 5t. S.E., Monroc, WA 98272 <br />August 20, 1997 <br />Duane Sterley <br />14824 W. Lake Goodwin Road <br />Stanwood, WA 98292 <br />(360) 652-0894 <br />Subject: Dreinage Review - Sterley Development -#12 Everett Mall Way <br />Phone /Faz: (360j 793-9659 <br />Pager.(425)290•U768 <br />E-Mail: rheide�premierl.net <br />�/rn ��irc� �: S6 y�S <br />As requested I have reviewed the proposed new building you plan to build @ the above address. I <br />talked to Kirk Brooks at the City of Everett and he believed it would be possible to run the drainage <br />lines under the buiiding as long as the pipe was ductile iron. <br />In accordance with the City of Everett drainage design standards, as long as you are not creating or <br />adding 5,000 s.f. of impervious area, no retention or water quality measures sre required. Based on <br />the proposed site plan you are proposing to add 4,644 s.f. of new impervious area. This does not <br />inciude the existing gravel area as impervious. As such the attached engineering addresses flow <br />capaciry only. It was de signed for the 25 and 100 yr. storms since the amount of drainage area was so <br />small. <br />Your existing sewer and water connections should be adequate for the proposed construction. <br />If you have any questions or I can be of any further assistance please call me at the above numbers. <br />� <br />Rick Heide, P.E. <br />President <br />Attachment <br />