Laserfiche WebLink
, „ <br /> // \\ <br /> covER ,N4HEEiT & PRojEc .7,-i INFO, <br /> 0 1., t <br /> STATEMENT OF USE 4 LIABILITY w tp Z'''v 6 --e_i- (/) <br /> THESE PLANS ARE FOR THE EXCLUSIVE USE OF SOUNDLINE CONSTRUCTION BCIE ASSUMES NO oc �w`, .. ',,.�, O <br /> RESPONSIBILITY OR LIABILITY FOR USE OF THESE PLANS BY OTHERS. ALL INFORMATION ON ass``is, , �w� v <br /> oosTHESE PLANS IS NE EXCLUSIVE PROPERTY OF BCIE AND DOES NOT EXPRESS NOR IMPLY �� -T - -� <br /> ANY WARRANTY OF NE INFORMATION ON THESE PLANS. <br /> B yv0002 � <br /> •o DESCRIPTION OF DAMAGE /SCOPE k <br /> 1. INTERIOR REMODEL INCLUDING BATHROOM, KITCHEN, EAST SIDE ATTIC BEDROOM, AND k� <br /> ALL WINDOWS AND INTERIOR DOORS. MUD ROOM FLOOR REPLACED DUE TO WATER <br /> DAMAGE. SUB FLOOR (SHEATHING) REPLACED FOR NEW FLOORING, PARTIAL • <br /> RELEVELING OF FLOOR AND RANDOM WATER DAMAGE TO FLOOR FRAMING. <br /> O k <br /> 2. ELECTRICAL 4 PLUMBING PERMITS OBTAINED FOR REMODEL. NEW BATHROOM AND q �, CV <br /> KITCHEN. NEW WINDOWS 4 INTERIOR DOORS. NEW MUD ROOM FLOOR NEW SUB FLOOR O Of) C <br /> OVER EXISTING FLOOR FRAMING W/ REPAIRS AS REQUIRED USING LIKE KIND 4 QUALITY <br /> MATERIALS. SEE PLANS FOR ADDITIONAL INFORMATION. k W <br /> ARCHITECTURAL/STRUCTURAL REPAIRS E� k E� <br /> PROVIDE (N) INTERIOR 4 EXTERIOR ARCHITECTURAL 4 STRUCTURAL CONSTRUCTION AS Cf) Ci) k <br /> NOTED PER THE PLANS. ALL (N) CONSTRUCTION SHALL COMPLY WIN THE 2015 IRC AS W <br /> AMENDED 4 ADOPTED BY NE LOCAL JURISDICTION. N W <br /> ELECTRICAL, MECHANICAL, 4 PLUMBING: ( W N <br /> PROVIDE (N) ELECTRICAL,MECHANICAL, 4 PLUMBING FIXTURES 4 SERVICES WITHIN THE <br /> DAMAGED AREAS AND AS OTHERWISE NOTED PER NE PLANS. ALL (N) CONSTRUCTION WILL <br /> BE BACK TO NE (E) ROUGH-INS. <br /> w <br /> J <br /> r <br /> BUILDING DESIGN NOTES <br /> t is owners responsibility to establish and s • <br /> property, lines. ARCHITECTURAL op <br /> O N <br /> NE CONTRACTOR AND SUBCONTRACTORS PERFORMING NE ARCHITECTURAL WORK, WHICH k ao O <br /> IF BUILDING IS NOT POSITIONED AS INCLUDES: EXTERIOR AND INTERIOR FINISHES, EXTERIOR FLASHING 4 CAULKING, INTERIOR <br /> INDICATED ON APPROVEDSHALL <br /> SITE PLAN, FLOORING, TRIM, ETC. DAMAGED BY NE Value Value SHALL REMOVE AND REPLACE NE <br /> A NEW SITE PLAN BE SUBMiT- ARCHITECTURAL ITEMS TO MATCH ORIGINAL CONDITIONS. NE ARCHITECTURAL WORK SHALL <br /> TED. NO FURTHER INSPECTIONS WILL <br /> BE MADE ON THIS PROJECT UNTIL THE BE PER THE 2015 lR AS AMMENDED 4 ADOPTED BY CITY OF EVERETT AND THE STATE OF Cf) O k <br /> REVISED SITE PLAN HAS BEEN APPROV® <br /> WASHINGTON. <br /> ED BY THE BUILDING/PUBLIC WORKS <br /> DEPTS. ° L.ELECTRICAL, MECHANICAL, 4 PLUMBING: <br /> NE CONTRACTOR AND SUBCONTRACTORS PERFORMING NE ELECTRICAL, MECHANICAL, 4 k <br /> GRADING Ali D Aliv.^G.E PLUMBING WORK SHALL INSTALL NEW ITEMS TO MATCH THE ORIGINAL ITEMS. SEPARATE "� N <br /> Y, Provisions shall be made for the control and drainage of surface <br /> PERMITS FOR ELECTRICAL AND MECHANICAL SHALL BE SUBMITTED TO CITY OF EVERETT 8Y N <br /> NE ELECTRICAL AND MECHANICAL CONTRACTORS. THE ELECTRICAL <br /> water around buildings by: gutters, drain lines, inlets and catch BUILDING DATA ' <br /> MECHANICAL <br /> basins or other necessary drainage structures and shall be installer! <br /> PROPANE TANKS, HEAT PUMPS AND CONTRACTORS ARE R 7SSF'ONSIBLE FOR SPECIFICATIONS OF ELECTRICAL SERVICES (AS 0 <br /> where storm water disposal cannot be obtained without their use (.. OTHER EQUIPMENT OR APPURTENANCES ADDRESS: 2411 STATE ST, EVERETT, WA 98201 REQ'D),MECHANICAL._ (AS REQ'D), 4 PLUMBING FIXTURES (AS REQ'D). ALL WORK C? <br /> MAY NOT BE LOCATED IN THE FRONT <br /> where erosion cannot be prevented by finish grading and planting. AND SIDE SETBACKS. PROPANE TANKSSHALL COMPLY WIN CURRENT ELECTRICAL, MECHANICAL, AND PLUMBING CODES AS <br /> Dry wells shall not be installed in areas where the soil is not well REQUIRE ADDITIONAL PERMITS ISSUED PARCEL NO: 00515653600800 0 <br /> AMMENDED 4 ADOPTED BY CITY OF EVERETT AND NE STATE OF WASHINGTON. <br /> `` � <br /> drained andjor porous. BY THE EVERETT FIRE DEPARTMENT LEGAL DESCRIPTION: MILEY LAND CO S 1ST ADD BLK 536 D-00 - <br /> PRIOR TO INSTALLATION. LOTS 8 4 9 O <br /> IN,2. Grading shall be provided to insure: PROJECT TEAM rn w <br /> i of water awayfrom buildings. BUILDING: TYPE V-B <br /> o � <br /> (a) Diversion OCCUPANCY: R-3 cn <br /> (b) Prevention of standing water and soil saturation detrimental co structures <br /> and lot use. o <br /> to Additional Permits Are Required MAIN FLOOR: 920 SgFt GARAGE: 600 SgFt <br /> c That natural drainage channels or basins are not blocked or CONTRACTOR: INVESTIGATIVE/RESTORATION ENGINEER � � � <br /> ATTIC: 396 SgFt SOUNDLINE CONSTRUCTION BC INVESTIGATIVE ENGINEERS �' �' oo <br /> For This Project Include: CONTRACTORS LICENSE°SOUNDC=866B2 L _ <br /> filled. <br /> (d) Provisions for the disposal of water from a lots Plumbing Sprinkler <br /> TOTAL SF.: 1�16 SgFt <br /> Le) Protection of adjoining property. p <br /> LOT: .14 Acres CONTACT: JESSE BINFORp, PE ►� �--� CD L-L1 <br /> Mechanical Fire AlarmYEAR BUILT: 1905 CONTACT: BRIAN LEWANDOWSKI PRINCIPAL F✓ 0_4 O t k <br /> 206.118.5895 (C) 253.610.9513 0 L. )., <br /> EA Electrical SEE THIS SHEET 4 PLANS FOR ADDITIONAL CODE ANALYSIS E -4 o <br /> ABBREVIATIONS LEGEND SHEET INDEX _ . <br /> o AB(s) ANCHOR BOLT(e) FT FOOT, FEET PNL PANEL PLAN TITLE Wl = SW DESIGNATION PER GENERAL H1T1No <br /> N ADEQ ADEQUATE FIG FOOTING PT POINT SW TABLE ON S10 C� Q o w <br /> N AD I. ADDITIONAL GA GAUGE FWD PLYWOOD SCALE: 1'=IID'-ID' PLAN TITLE UNDERLINE CS COVER SHEET [Ti c <br /> c ALUM ALUMINUM GALV GALVANIZED REINF REINFORCEMENT a <br /> o <br /> N BLDG BUILDING GCB GYPSUM CEILING BOARD RQD REQUIRED <br /> il BLKG BLOCKING GLB GLULAM BEAM SI SQUARE INCHES /N A I = REVISION NUMBER ARCHITECTURAL: STRUCTURAL Z n 0, <br /> o BM BEAM GLIB GYPSUM WALL BOARD SC SOLID CORE _AlORTH ARROW <br /> A1.0 DESIGN NOTES S1.0 TYPICAL STRUCTURAL NOTES • w <br /> • BOT BOTTOM HC HOLLOW CORE SHI SHEET — 0 INDICATES AREA WITH A REVISION O <br /> 0AI.1 MAIN FLOOR 4 ATTIC FLOOR PLANS 52.0 PARTIAL FOUNDATION 4 CRAWL SPACE <br /> BRCx BEARING Hp(s) HOLpOWN(s) SHTG SHEATHING 4 TYPICAL EXTERIOR WALL SECTION FRAMING PLAN 4 DETAILS Uj �a � <br /> o i GMN CEENTE LINE NDWR) HARDWARE SIM <br /> SIMILAR <br /> LAB ON GRADE A DETAIL TITLE DETAIL/SECTION TITLE UNDERLINE SMOKEDETECTOR <br /> o GTR(d) CENTER, CENTERED HF HEM FIR SPCG SPACING SXX SCALE: 1'=1'-ID' SXx = SHEET WHERE DETAIL/SECTION ON <br /> N= NEW E = EXIST OZ wN CLG CEILING HORIZ HORIZONTAL SO SQUARE — IS DRAWN5 TOTAL SHEETS, THIS SET • <br /> W CLR CLEAR IBC INTERNATIONAL BUILDING CODE SgFt SQUARE FEET CARBON MONOXIDE ALARM (i" <br /> wCOL COLUMN I/F INSIDE FACE STRUCT STRUCTURALI = DETAIL NUMBER N N= NEW E = ExlsT VICINITY MAP <br /> COMP COMPOSITION, COMPOSITE INSUL INSULATION SW SHEAR WELL 0 SX.X = REFERENCE WHERE DETAIL �° Cij <br /> z CONC CONCRETE INT INTERIOR T4G TOUNGE 4 GROOVE ® IS TAKEN C) EXHAUST FAN SOcfm BATH <br /> Q CONT CONTINUOUS IRC INTERNATIONAL RESIDENTIAL CODI: TYP TYPICAL N N= NEW E = EXIST 100cfm KITCHEN <br /> o CONIR CONTRACTOR JT JOINT UNO UNLESS NOTED OTHERWISE �. <br /> CIV CONTRACTOR TO VERIFY LAM(s) LAMINATION(s) VERT VERTICAL 1 = SECTION NUMBER l 3 , <br /> o NOT WATER HEATER q L. <br /> („ DEMO DEMOLISH, DEMOLITION lbs POUNDS W/ WITH 0 SX.X = REFERENCE WHERE SECTION <br /> Z IS TAKEN ri:N N= NEW E = EXIST IF - .- q > L <br /> a DF DOUGLAR FIR MAX MAXIMUM W/O WITHOUT <br /> DI $ DIAMETER A, MFR MANUFACTURER WIN WINDOW EXISTING WALLS TO REMAIN O <br /> f' <br /> a DIST DISTANCE MIN MINIMUM WSEC WASHINGTON STATE ENERGY CODE <br /> r, <br /> 8 OIL DETAIL (N) NEW XFR TRANSFER 0 1 = ELEVATION NUMBER <br /> SX.X = REFERENCE WHERE ELEVATION <br /> EXISTING WALLS TO BE REMOVED Permit#: BW2002-005 <br /> o (E) EXISTING NOM NOMINAL <br /> o EA EACH O.G. ON CENTER IS TAKEN Site Address: 2417 STATE ST (N <br /> EQ EQUAL O/F OUTSIDE FACE Qwner. SOUNDLINE CONSTRUCTION LLC O •� O <br /> QI DOOR MARK PER SCHEDULE %/////- NEW 2x�/2x6 WALLS/SNEAK WALLS Tenant: [TenName] W <br /> m ES EA SIDE OSB ORIENTED STRAND BOARD App. Date: 2/19/2020 o O <br /> i EW EACH WAY OH OVERHANG O WINDOW MARK PER SCHEDULE Proposed Use: SFR O <br /> X EXT EXTERIOR PE PRE ENGINEERED m DEDICATED EXHAUST ROOF PENIS Description: REMOVE/REPLACE PEST DAMAGED AND <br /> ROTTED FRAMING N Li) <br /> hi FF FLUSHED FRAMED, FINISHED FLOOR lE PLATE <br /> Reviewed By: sV Date: z0 I <br /> Z FLR FLOOR PLCS PLACES <br /> . FND FOUNDATION P-NAILS PNEUMATIC NAILS office Set Job Site Set Fire/Planning Set <br />