My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6003 23RD DR W 2021 VIGILANT Plans 2022-11-08
>
Address Records
>
23RD DR W
>
6003
>
VIGILANT
>
Plans
>
6003 23RD DR W 2021 VIGILANT Plans 2022-11-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 10:47:18 AM
Creation date
12/15/2021 8:42:06 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
6003
Tenant Name
VIGILANT
Permit
B2103-044
Year
2021
Notes
Partial demo of interior walls to create future suites
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
01 <br />l <br />A <br />SHEETINDEX <br />GENERAL <br />01 Cover Sheet, Project Information & Code Analysis <br />ARCHITECTURAL <br />A1.00 Demo Plan ® Floor Plan <br />A1.01 Second Floor RCP ® Demo <br />US: <br />" <br />VI m <br />6003 23rd Drive West, Ste. 200 <br />Everett, WA 98203_ <br />Contact: Brandon Dion <br />Phone: (50) 6201710 <br />Fax: <br />Email: BrandonD@vigilant.org <br />D keman <br />1716 West Marine View Drive <br />Everett, WA <br />98201 -2098 <br />Contact: <br />Tim Jewett <br />Phone: <br />(425) 870 5121 <br />Fax: <br />(425) 259 5242 <br />Email: <br />tirnjdykeman.net <br />Address: 6003 23RD DRIVE WEST, Everett, WA 96206 <br />Zoning: BIVIU-65 <br />Use: COMMERCIAL <br />WSEC <br />Existing Building is heated and fully insulated as per WSEC standard. <br />APPLICABLE CODES AND REF EFRENCES <br />Automatic Fire Detection & Suppression Systems Ordinance No. 1902-92 <br />International Building Code (IBC),2015 Edition & WAC 51-50 <br />® International Exiting Building Code (IEBC),2015 Edition & WAC 51-50 <br />® International Property Maintenance Code (IPMC), 2015 Edition & WA 51-50 <br />® Accessible and Usable Building Facilities, ANSI Al17.1-2009 & WAC 51-50-005 <br />® International Fire Code (IFC), 2015 Edition & VVAC51-54 <br />International Mechanical Code (IMC), 2015 Edition & WAC 51-52 <br />• National Electric Code (NEC), 2017 Edition & WAC 296-4613-010 <br />m Uniform Plumbing Code (UPC), 2015 Ediyion & WAC 51-56 &51-57 <br />® Washington State Energy Code (WSEC), 2015 Edition, WAC 51-11 (C, R, Appendix) <br />Everett Municiple Code, Title 19 Zoning <br />DEFERRED SUBMITTALS <br />Plumbing and Electrical Components of this project are bidder design, deffered submittal under a <br />separate permit. Design intent is as shown on the drawings. <br />JAN <br />JANITOR <br />AND <br />JT <br />JOIST <br />AID <br />ANCHOR BOLT <br />JST <br />JOLT <br />ACT <br />ACOUSTICAL CEILING TILE <br />ADD <br />ADDENDUM <br />L. <br />LENGTH <br />A.F.F. <br />ABOVE FINISH FLOOR <br />LAV <br />LAVATORY <br />ALS <br />AREA LIGHT STANDARD <br />LB <br />LAG BOLT <br />ALUM <br />ALUMINUM <br />LKR <br />LOCKER <br />ANOD <br />ANODIZED <br />LS <br />LANDSCAPING <br />LVR <br />LOUVER <br />BC <br />BOTTOM OF CURB <br />BD <br />BOARD <br />MAT'L <br />MATERIAL <br />BLDG <br />BUILDING <br />MAX <br />MAXIMUM <br />BLKG <br />BLOCKING <br />MB <br />MARKERBOARD <br />B.M. <br />BENCH MARK <br />MECH <br />MECHANICAL <br />BM <br />REAM <br />MED <br />MEDIUM <br />BOT <br />BOTTOM <br />MEZZ <br />MEZZANINE <br />BTU <br />BRITISH THERMAL UNIT <br />MFR <br />MANUFACTURER <br />BTWN <br />BETWEEN <br />MH <br />MANHOLE <br />MIS <br />MINIMUM <br />OR C CHANNEL <br />MIR <br />MIRROR <br />CB <br />CATCH BASF! <br />M <br />MISCELLANEOUS <br />CCTV <br />CLOSED CIRCUIT TV <br />MTD <br />MOUNTED <br />CG <br />CORNER GUARD <br />MTL <br />METAL <br />C.I.P. <br />CAST IN PLACE <br />CLG <br />CEILING <br />NA <br />NOT APPLICABLE <br />CLR <br />CLEAR <br />NIC <br />NOT IN CONTRACT <br />CJ <br />CONTROL JOINT <br />NOM <br />NOMINAL <br />CMU <br />CONCRETE MASONRY UNIT <br />NS <br />NELSON STUD <br />CONT <br />CONTINUOUS <br />NTS <br />NOT TO SCALE <br />CORR <br />CORRIDOR <br />CS.J <br />CONSTRUCTION JOIST <br />OA <br />OVERALL <br />CSMT <br />CASEMENT <br />OC <br />ON CENTER <br />CT <br />CERAMIC TILE <br />O.D. <br />OVERFLOW DRAIN <br />CTR <br />CENTER <br />OD <br />OUTSIDE DIAMETER <br />CENTERLINE <br />OFCI <br />OWNER FURNISHED CONTRACTOR <br />DBL <br />DOUBLEINSTALLED <br />OFOI <br />OWNER FURNISHED OWNER <br />DTL <br />DETAIL <br />ISSTAI�LED <br />DF <br />DRINKING FOUNTAIN <br />OH <br />OVERHEAD <br />DIA <br />DIAMETER <br />OPNG <br />OPENING <br />DIAL <br />DIAGONAL <br />OPP <br />OPPOSITE <br />DIM <br />DIMENSION <br />OS <br />OUTSIDE <br />DISP <br />DISPENSER <br />DN <br />GOWN <br />PIP <br />POURED IN PLACE <br />DP <br />DAMPROOFING <br />PL <br />PROPERTY LINE <br />DR <br />DOOR <br />PLAS <br />PLASTER <br />DS <br />DOWN SPOUT <br />PLYWD PLYWOOD <br />DT <br />DRAIN TILE <br />PSF <br />PER SQUARE FOOT <br />DWG <br />DRAWING <br />P.T. <br />PRESSURE TREATED <br />PVMT <br />PAVEMENT <br />EA <br />EACH <br />EF <br />EXHAUST FAN <br />R. <br />RADIUS <br />EJ <br />EXPANSION JOINT <br />R.D. <br />ROOF DRAIN <br />EL <br />ELEVATION <br />REF <br />REFERENCE <br />ELEC <br />ELECTRICAL <br />REFR <br />REFRIGERATOR <br />E.O.S. <br />EDGE OF SLAB <br />REQ'D <br />REQUIRED <br />ENGR <br />ENGINEER <br />REV <br />REVISE OR REVISION <br />EP <br />ELECTRICAL PANEL <br />RM <br />ROOM <br />EQ <br />EQUAL <br />R.O. <br />ROUGH OPENING <br />EQUIP <br />EQUIPMENT <br />RCP <br />REFLECTED CEILING PLAN <br />ES <br />EACH SIDE <br />EW <br />EACH WAY <br />SB <br />SMART BOARD <br />EXST <br />EXISTING <br />SC <br />SOLID CORE <br />(E) <br />EXPANSION <br />SECT <br />SECTION <br />EXT <br />EXTERIOR <br />SF <br />SQUARE FOOT <br />SHTG <br />SHEATHING <br />FA <br />FIRE ALARM <br />SH <br />SHOWER <br />FBO <br />FURNISHED BY OTHERS <br />SM T <br />SHEET <br />FD <br />FLOOR DRAIN <br />SI <br />SIMILAR <br />FDN <br />FOUNDATION <br />SJ <br />SEISMIC JOINT <br />FE <br />FIRE EXTINGUISHER <br />SPi <br />SHEET METAL <br />FEC <br />FIRE EXTINGUISHED CABINET <br />SPEC <br />SPECIFICATION <br />FF <br />FINISH FLOOR <br />SQ <br />SQUARE <br />FFE <br />FINISH FLOOR ELEVATION <br />SS <br />STAINLESS STEEL <br />FIN <br />FINISH <br />STD <br />STANDARD <br />FIO <br />OWNER FURNISHED OWNER <br />STL <br />STEEL <br />INSTALLED <br />STOR <br />STORAGE <br />F L <br />FLOOR <br />STRUCTSTRUCTURAL <br />FL <br />FACE OF <br />SUSPENDED <br />FOIL <br />OWNER FURNISHED CONTRACTORSUS <br />INSTALLED <br />T <br />TEMPERED GLAZING <br />FOC <br />FACE OF CONCRETE <br />TC <br />TOP OF CURB <br />FOF <br />FACE OF FINISH <br />TEL <br />TELEPHONE <br />FOM <br />FACE OF MASONRY <br />T&G <br />TONGUE AND GROOVE <br />FOS <br />FACE OF STUD <br />THK <br />THICK <br />FRT <br />FIRE RETARDANT TREATED <br />TJ <br />TOOL JOINT <br />FTG <br />FOOTING <br />TP <br />TOP OF PAVEMENT <br />FURR <br />FURRING <br />TYP <br />TYPICAL <br />TOD <br />TOP OF (MATERIAL) <br />GA <br />GAUGE <br />TOP <br />TOP OF PARAPET <br />GALV <br />GALVANIZED <br />TOS <br />TOP OF STRUCTURE <br />GB <br />GRAB BAR <br />GC <br />GENERAL CONTRACTOR <br />UNFIN <br />UNFINISHED <br />GL <br />GLASS <br />UNO <br />UNLESS SATED OTHERWISE <br />GND <br />GROUND <br />GVP <br />GYPSUM VENEER PLASTER <br />VB <br />VAPOR BARRIER <br />GWB <br />GYPSUM WALL BOARD <br />VERT <br />VERTICAL <br />VEST <br />VESTIBULE <br />HB <br />HOSE BIB <br />VFY <br />VERIFY <br />HC <br />HANDICAP <br />HDWR <br />HARDWARE <br />W/ <br />WITH <br />HM <br />HOLLOW METAL <br />WC <br />WATER CLOSET <br />HW <br />HOT WATER <br />WD <br />WOOD <br />HVAC <br />HEATING, VENTILATION AND <br />WF <br />WIDE FLANGE <br />AIR CONDITIONING <br />WG <br />WIRE GLASS <br />WH <br />WATER HEATER <br />INSUL <br />INSULATION <br />W/O <br />WITHOUT <br />INT <br />INTERIOR <br />WP <br />WATERPROOFING <br />WT <br />WEIGHT <br />SYMBOLSLEGEND <br />North Arrow <br />NORTH <br />Dimensional Control <br />Q }— + — Grid <br />A P0 i .isIE ,✓ 3 i iS,.n A74C E 0F <br />® P U18L I C �M1) R KS, ?1 1 ,(J H A N CAI , FIRE- <br />'ELECTMAL OR <br />Dame 0 Level Datum <br />Elevation <br />Centerline Mark <br />Spot Elevation - Crosshair <br />Spot Elevation - Target Filled <br />User Noce Location & Label <br />Drawing Callout Types <br />Exterior Elevation Callout <br />Ty OF EVERETT <br />REVIEWED IE DR PERMIT <br />Interior Elevation Callout <br />1 / A101 <br />1 SIM <br />A101 <br />IM <br />S <br />1 <br />',A101 Building Section <br />SIM <br />41 <br />A Wall Section <br />1 \ SIM <br />ORMIL1 Detail Section <br />A101 <br />Building Element Tags <br />_00 00 00.00-J Keynote Reference <br />150 Area Name & Square Footage <br />ROOM NAME <br />101 <br />WS00 <br />GA <br />Wall Type <br />1 11 Door Number <br />Storefront Type <br />RA <br />Mark <br />WHD <br />00 <br />Window Type <br />Ceiling Elevation from Floor Level <br />Roof Assembly Type <br />Casework Type <br />Revisions <br />:o <br />Material Mark <br />Revision Number <br />Permit#: <br />B2103-044 <br />Site Address: <br />6003 23RD DR W <br />Owner: <br />TOC MANAGEMENT SERVICES <br />Tenant: <br />NETALLY/ VIGILANT <br />App. date: <br />3/W2021 <br />Proposed Use: <br />COMMERCIAL ALTERATIONS <br />Description: <br />PARTIAL DEMO OF INTERIOR WALLS TO <br />CREATE FUTURE SUITES <br />� 6 ° <br />Reviewed By: <br />Date-0 <br />Office Set <br />Jab Site Set Fire%Planning Set <br />6467 REGISTERED <br />ARCHITECT <br />. ..,. } <br />TI 10� yY JAU EUJETT <br />S ATE 'OF 'NASHI GTON <br />§ e P s - <br />y4 $ <br />This drawing is: <br />1. Copyright 2017 Dykeman, Inc. <br />2. The Architect's Instrument of Professional Service, <br />3. For use on this project only. Obtain Architect's <br />written permission for any other use or reproduction. <br />01 <br />�I <br />3 4 I 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.