|
OPTIONS LIST
<br />INTERIOR OPTIONS
<br />ElL PROJECT= OPTION NOT INCLUDED IN SET ®= OPTION INCLUDED IN SET WENDY'S ADDITION & EXTERIOR REMODE
<br />EXTERIOR OPTIONS
<br />DESCRIPTION
<br />DESCRIPTION
<br />DESCRIPTION
<br />DESCRIPTION
<br />DESCRIPTION
<br />DESCRIPTION
<br />DESCRIPTION
<br />NEW STATIC MENU BOARD
<br />NEW CEILING TILES
<br />MUSIC W/ CEILING MOUNTED SPEAKERS
<br />FREESTANDING FIREPLACE
<br />■
<br />NEW BUILDING SIGNAGE
<br />❑
<br />ACM BLADE WALL
<br />NEW STATIC QUEUING BOARD
<br />NEW CEILING GRID
<br />SEPARATE ORDER/PAY FROM PICK-UP
<br />ACCESSIBLE BAR SEATING
<br />❑
<br />REMOVE DIRECTIONALS
<br />N
<br />NEW STATIC RHR
<br />NEW PENDANT LIGHTS
<br />REPLACE WINDOW SILLS W/ SOLID SURFACE
<br />❑
<br />LANDSCAPING
<br />SELF SERVE DRINK - ONE FREESTYLE
<br />REPLACE SERVICE COUNTER BACK WALL FINISHES
<br />REPLACE RESTROOM FINISHES & FIXTURES
<br />■
<br />RED FLAG BLADE
<br />AUG 0 2 2022
<br />CONDIMENT STAND
<br />ARTPACK
<br />ONE FREESTYLE IN DT
<br />■
<br />NEW CORRUGATED PANELS
<br />NEW DRINK STAND (SMALL, PLUMBED)
<br />WIFI SERVICE
<br />(1) - 55" TV
<br />■
<br />PAINT (E) WALL SCONCES
<br />ARCHIV
<br />NEW DRINK STAND (LARGE, PLUMBED)
<br />ALL WOOD LOOK PORCELAIN PLANK TILE
<br />❑
<br />PAINT (E) STOREFRONT
<br />GENERAL NOTES
<br />1. DISCREPANCIES BETWEEN THESE DOCUMENTS AND THE ACTUAL FIELD
<br />CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE
<br />ARCHITECT BEFORE PROCEEDING WITH WORK.
<br />2. REVIEW DOCUMENTS AND VERIFY DIMENSIONS AND FIELD
<br />CONDITIONS AND CONFIRM THAT WORK IS CONSTRUCTIBLE AS
<br />SHOWN. CONFLICTS OR OMISSIONS, ETC., SHALL BE IMMEDIATELY
<br />REPORTED TO THE ARCHITECT FOR CLARIFICATION PRIOR TO THE
<br />PERFORMANCE OF WORK IN QUESTION.
<br />3. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN PARTITION
<br />LOCATIONS. IN CASE OF CONFLICT, NOTIFY THE ARCHITECT OF
<br />RECORD. FLOOR PLAN BY ARCHITECT OF RECORD SUPERSEDES
<br />OTHER PLANS. DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED
<br />AND SHALL ALLOW FOR THICKNESS OF FINISHES INCLUDING CARPET,
<br />PAD, CERAMIC TILE, V.C.T., ETC.
<br />4. INTERIOR DIMENSIONS ARE TO THE FACE OF NEW STUD, UNLESS
<br />NOTED OTHERWISE.
<br />5. COLUMN CENTER LINE (OR GRID LINES) ARE SHOWN FOR
<br />DIMENSIONING. VERIFY EXACT LOCATIONS IN FIELD.
<br />6. MARK LOCATIONS OF PARTITIONS AND DOORS FOR REVIEW BY THE
<br />OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. REVIEW WILL BE
<br />FOR DESIGN INTENT. COORDINATE AND VERIFY CONDITIONS TO
<br />ENSURE PROPER FIT.
<br />7. CONTRACTOR IS REQUIRED TO SCHEDULE A PRE -CONSTRUCTION
<br />MEETING WITH THE OWNER'S REPRESENTATIVE TO REVIEW SPECIFIC
<br />REQUIREMENTS. CONTRACTOR IS RESPONSIBLE TO FOLLOW THE
<br />WENDY'S COMPANY RULES AND REGULATIONS.
<br />8. WHEN CONTRACTOR ACCEPTS DELIVERY OF ALL ITEMS NOTED ON
<br />PLANS WHETHER IN CONTRACT OR NOT IN CONTRACT, HE SHALL BE
<br />RESPONSIBLE FOR LOSS AND/OR DAMAGE TO THESE ITEMS.
<br />9. THE CONTRACTOR SHALL MAINTAIN, FOR THE ENTIRE DURATION OF
<br />THE WORK, ALL EXITS, EXIT/ EGRESS LIGHTING, FIRE PROTECTION
<br />DEVICES AND ALARMS IN CONFORMANCE WITH ALL APPLICABLE
<br />CODES AND ORDINANCES.
<br />10. EXISTING WORK: WITH PRIOR APPROVAL OF THE OWNER'S
<br />REPRESENTATIVE AND RETURN OF PROPER CREDIT, EXISTING WORK
<br />WHICH FITS THE SCHEME MAY BE RE -USED.
<br />11. DEMOLITION: REMOVE INTERIOR PARTITIONS, CASEWORK,
<br />STOREFRONTS, CEILING, FINISHED FLOORING AND OTHER ITEMS NOT
<br />USED IN NEW SCHEME. REMOVE UTILITIES, ELECTRICAL, PLUMBING,
<br />PIPING AS REQUIRED BACK TO EXISTING CONSTRUCTION AND
<br />TERMINATE AND/OR CAP AS REQUIRED BY LOCAL AUTHORITIES.
<br />12. SAW CUTTING AND CORING LOCATIONS SHALL BE REVIEWED IN FIELD
<br />AND COORDINATED WITH THE OWNER'S REPRESENTATIVE PRIOR TO
<br />CUTTING/CORING.
<br />13. DURING ALL PHASES OF WORK, DO NOT DISTURB THE DELIVERIES AND
<br />FUNCTIONS OF ADJACENT AND NEIGHBORING TENANTS.
<br />14. 'TYP.' MEANS THAT THE CONDITION IS REPRESENTATIVE FOR SIMILAR
<br />CONDITIONS THROUGHOUT, UNLESS OTHERWISE NOTED.
<br />15. PROVIDE PORTABLE FIRE EXTINGUISHER(S) IN ACCORDANCE WITH
<br />NFPA 10, WITH U.L. LABEL AND A RATING OF NOT LESS THAN 2-A WITH
<br />75 FT. TRAVEL DISTANCE TO ALL POSITIONS OF RESTAURANT OR AS
<br />DIRECTED BY THE FIRE DEPARTMENT FIELD INSPECTOR. PROVIDE
<br />CLASS K FIRE EXTINGUISHER WITHIN 20 FT. OF COMMERCIAL FOOD
<br />HEAT -PROCESSING EQUIPMENT.
<br />16. EXTERIOR BUILDING SIGNS SHALL BE SUBMITTED UNDER SEPARATE
<br />PERMIT APPLICATION FOR REVIEW AND APPROVAL AS REQUIRED BY
<br />w LOCAL AUTHORITIES. EXTERIOR SIGNS ARE NOT WITHIN THE SCOPE OF
<br />BUILDING DEPARTMENT APPROVAL.
<br />0 17. PRIOR TO COMMENCEMENT OF WORK, AS REQUIRED BY GOVERNING
<br />JURISDICTION, OBTAIN A COPY OF THE BUILDING CONSTRUCTION
<br />a PERMIT FROM THE AUTHORITY HAVING JURISDICTION (AHJ) AND A
<br />COPY OF THE SET OF CONSTRUCTION DOCUMENTS SIGNED AND
<br />co
<br />SEALED BY A LICENSED DESIGN PROFESSIONAL FOR ALL DISCIPLINES
<br />Q� AS REQUIRED AND USED TO OBTAIN THE BUILDING PERMIT.
<br />18. IF REQUIRED BY LOCAL JURISDICTION - SPRINKLER, LIFE SAFETY, AND
<br />W FIRE ALARM SYSTEMS ARE TO BE DESIGNED AND SUBMITTED FOR
<br />a� REVIEW AND APPROVAL BY LOCALLY LICENSED DESIGN
<br />c PROFESSIONAL. THE DESIGN OF SYSTEM(S) MUST COMPLY TO LOCAL,
<br />STATE, AND NATIONAL CODES.
<br />i
<br />9 19. EXISTING ENERGY MANAGEMENT SYSTEM (VERIFY IN FIELD) TO REMAIN
<br />a IN STORE AND BE FULLY FUNCTIONAL AND OPERATIONAL AT
<br />co
<br />COMPLETION OF PROJECT.
<br />co
<br />UI 20. COORDINATE SALVAGE AND REUSE OF EXISTING FIXTURES AND
<br />EQUIPMENT WITH OWNER'S REPRESENTATIVE.
<br />CONSTRUCTION / PRODUCT WARRANTIES
<br /><I THESE CONSTRUCTION DOCUMENTS NOTE SPECIFIC PRODUCTS, DETAILS
<br />AND SPECIFICATIONS THAT WILL PROVIDE CONSTRUCTION / PRODUCT
<br />W WARRANTIES FOR THE FOLLOWING AREAS OF CONSTRUCTION:
<br />04
<br />ROOFING (DURO-LAST)
<br />INTERIOR TILE (LATICRETE)
<br />a EIFS (STO-CORP)
<br />ALTERING THESE DOCUMENTS MAY ALTER THE WARRANTY GUIDELINES.
<br />DURO-LAST AND LATICRETE WILL BE REQUIRED TO APPROVE THE
<br />DRAWINGS TO MAINTAIN THE WARRANTIES. THE CONTRACTOR IS ALSO
<br />o RESPONSIBLE FOR CONTACTING, DURO-LAST, LATICRETE AND STO FOR
<br />ON -SITE INSTALLATION INSPECTIONS OF EACH OF THE AREAS OF WORK.
<br />a
<br />FRANCHISEES HAVE THE OPTION OF NOT FOLLOWING WENDY'S
<br />Cd CORPORATE WARRANTY RECOMMENDATIONS OUTLINED IN THE THESE
<br />N DOCUMENTS.
<br />N
<br />co
<br />ABBREVIATIONS
<br />CENTERLINE
<br />I.D.
<br />INSIDE DIAMETER
<br />ACM
<br />ALUMINUM COMPOSITE PANEL
<br />INSUL.
<br />INSULATION
<br />ACT
<br />ACOUSTICAL CEILING TILE
<br />JT.
<br />JOINT
<br />ADJ.
<br />ADJUSTABLE
<br />KED
<br />KITCHEN EQUIPMENT DISTRIBUTOR
<br />A.F.F.
<br />ABOVE FINISH FLOOR
<br />LAM
<br />LAMINATE
<br />A.H.J.
<br />AUTHORITY HAVING JURISDICTION
<br />LB(S).
<br />POUND(S)
<br />ALUM.
<br />ALUMINUM
<br />MAX.
<br />MAXIMUM
<br />A.O.R.
<br />ARCHITECT OF RECORD
<br />MECH.
<br />MECHANICAL
<br />ARCH.
<br />ARCHITECTURAL
<br />MFR.
<br />MANUFACTURER
<br />BD.
<br />BOARD
<br />MGR.
<br />MANAGER
<br />BLDG.
<br />BUILDING
<br />MIN.
<br />MINIMUM
<br />BLKG.
<br />BLOCKING
<br />MISC
<br />MISCELLANEOUS
<br />BM.
<br />BEAM
<br />MTL.
<br />METAL
<br />BOT.
<br />BOTTOM
<br />N.
<br />NORTH
<br />CAB.
<br />CABINET
<br />N.I.C.
<br />NOT IN CONTRACT
<br />CER.
<br />CERAMIC
<br />N.T.S.
<br />NOT TO SCALE
<br />CLG.
<br />CEILING
<br />(N)
<br />NEW
<br />CLKG.
<br />CAULKING
<br />NO.
<br />NUMBER
<br />CLR.
<br />CLEAR
<br />NOM.
<br />NOMINAL
<br />COL.
<br />COLUMN
<br />O.D.
<br />OUTSIDE DIAMETER
<br />CONC.
<br />CONCRETE
<br />OPNG.
<br />OPENING
<br />CONT.
<br />CONTINUOUS
<br />OPP.
<br />OPPOSITE
<br />COORD.
<br />COORDINATE
<br />P.LAM.
<br />PLASTIC LAMINATE
<br />DBL.
<br />DOUBLE
<br />PL.
<br />PLATE
<br />DET.
<br />DETAIL
<br />PLAS.
<br />PLASTER
<br />DIA.
<br />DIAMETER
<br />PLYWD.
<br />PLYWOOD
<br />DIM.
<br />DIMENSION
<br />PR.
<br />PAIR
<br />DND
<br />DO NOT DISTURB
<br />PT.
<br />POINT
<br />DR.
<br />DOOR
<br />P.T.
<br />PRESSURE -TREATED
<br />IDS.
<br />DOWNSPOUT
<br />P.U.W.
<br />PULL UP WINDOW
<br />DWG.
<br />DRAWING
<br />RAID.
<br />RADIUS
<br />(E)
<br />EXISTING
<br />REF.
<br />REFERENCE
<br />EA.
<br />EACH
<br />REG.
<br />REGISTER
<br />ELEV.
<br />ELEVATION
<br />REQ'D.
<br />REQUIRED
<br />ELEC.
<br />ELECTRICAL
<br />RM.
<br />ROOM
<br />EMER.
<br />EMERGENCY
<br />S.
<br />SOUTH
<br />EQ.
<br />EQUAL
<br />S.C.
<br />SOLID CORE
<br />F/MAS
<br />FACE OF MASONRY
<br />S.F.
<br />SQUARE FOOT
<br />F.D.
<br />FLOOR DRAIN
<br />S.S.
<br />STAINLESS STEEL
<br />F.D.N.
<br />FOUNDATION
<br />SCHED.
<br />SCHEDULE
<br />F.E.
<br />FIRE EXTINGUISHER
<br />SHT.
<br />SHEET
<br />F.O.
<br />FACE OF
<br />SHTHG.
<br />SHEATHING
<br />F.O.F.
<br />FACE OF FINISH
<br />SIM.
<br />SIMILAR
<br />F.O.S.
<br />FACE OF STUDS
<br />S.O.W.
<br />SCOPE OF WORK
<br />F/F
<br />FINISH TO FINISH
<br />SPEC.
<br />SPECIFICATION
<br />F.R.
<br />FIRE RETARDANT
<br />SQ.
<br />SQUARE
<br />FIN.
<br />FINISH
<br />STD.'
<br />STANDARD
<br />FL.
<br />FLOOR
<br />STL.
<br />STEEL
<br />FLUOR.
<br />FLUORESCENT
<br />STOR.
<br />STORAGE
<br />FT.
<br />FOOT, FEET
<br />SUSP.
<br />SUSPENDED
<br />F.V.
<br />FIELD VERIFY
<br />T.C.
<br />TIME CLOCK
<br />G.B.
<br />GRAB BAR
<br />T.O.
<br />TOP OF
<br />G.C.
<br />GENERAL CONTRACTOR
<br />TEL.
<br />TELEPHONE
<br />GA.
<br />GAUGE
<br />THK.
<br />THICK
<br />GL.
<br />GLASS
<br />TYP.
<br />TYPICAL
<br />GYP.
<br />GYPSUM
<br />U.N.O.
<br />UNLESS NOTED OTHERWISE
<br />H.
<br />HIGH
<br />VERT.
<br />VERTICAL
<br />H.C.
<br />HOLLOW CORE
<br />V.I.F.
<br />VERIFY IN FIELD
<br />H.M.
<br />HOLLOW METAL
<br />W.
<br />WEST
<br />HC.
<br />HANDICAPPED
<br />W/
<br />WITH
<br />HDWD.
<br />HARDWOOD
<br />W/C
<br />WATER CLOSET
<br />HORIZ.
<br />HORIZONTAL
<br />W/O
<br />WITHOUT
<br />HGT.
<br />HEIGHT
<br />W/R
<br />WATER RESISTANT
<br />H.T.
<br />HANGER -TIGHT UNIT
<br />WD.
<br />WOOD
<br />HVAC
<br />HEATING, VENTILATION,
<br />AIR CONDITIONING
<br />SYMBOLS LEGEND
<br />x.x
<br />NEW GRID LINE
<br />DETAIL REFERENCE
<br />SHEET NUMBER
<br />DOOR MARK
<br />q
<br />ELEVATION NUMBER &
<br />0
<br />WINDOW MARK
<br />II 6A �12
<br />DIRECTION
<br />10
<br />SHEET NUMBER
<br />KEY NOTE
<br />ELEVATION HEIGHT TARGET
<br />T .PARAPET
<br />O.
<br />LOCATION IN SPACE
<br />XXX EQUIPMENT NOTE
<br />cILlt�
<br />4 ELEVATION REFERENCE I FLOOR
<br />FINISH CODE (SEE
<br />SCHEDULE)
<br />wAu
<br />I BASE
<br />SHEET NUMBER
<br />0
<br />REVISION SYMBOL
<br />SECTION DETAIL REFERENCE
<br />,G SHEET NUMBER
<br />O
<br />REVISION CLOUD
<br />NAME ROOM NAME
<br />i01A
<br />ROOM NUMBER
<br />DESCRIPTIVE SUMMARY OF WORK
<br />THE WORK INCLUDES ALL LABOR, MATERIALS, AND EQUIPMENT TO
<br />REPLACE EXISTING PRE -FABRICATED FASCIA FOR A PROPOSED REFRESH
<br />OF AN EXISTING RESTAURANT FOR THE "OWNER". ADD NEW 250 SF
<br />WALK-IN BOX TO REAR OF BUILDING, MINOR REMODEL OF KITCHEN
<br />RELOCATING THE 2 & 3 COMPARTMENT SINKS AND MOP SINK
<br />THE WORK SHALL INCLUDE ALL ITEMS REQUIRED AS SHOWN ON THE
<br />DRAWINGS. ALL ELECTRICAL SYSTEMS ARE TO BE INCLUDED FOR A
<br />COMPLETE OPERATING SYSTEM WITH COORDINATION AND INSTALLATION
<br />INCLUDED.
<br />REFER TO SITE PLAN FOR UPGRADES REQ'D AT THE ACCESSIBLE PATH
<br />CODE DATA AND SQUARE FOOTAGE
<br />STORE TYPE: 3076 EXTERIOR IMAGE & REFRESH UPGRADE
<br />LOCATION: 2510 BROADWAY
<br />BUILDING LEVEL: 11 OF 1
<br />2015 VERSION BUILDING: INTERNATIONAL BUILDING CODE
<br />OF APPLICABLE EXISTING BUILDING: INTERNATIONAL EXISTING BUILDING CODE
<br />CODES: PLUMBING: UNIFORM PLUMBING CODE
<br />ELECTRICAL: NATIONAL ELECTRICAL CODE
<br />MECHANICAL: INTERNATIONAL MECHANICAL CODE
<br />FIRE: INTERNATIONAL FIRE CODE
<br />GAS: INTERNATIONAL FUEL GAS CODE
<br />ENERGY: WASHINGTON STATE ENERGY CODE
<br />ACCESSIBILITY: ADA STANDARDS/ANSI Al 17.1.2009
<br />ZONING BMU
<br />CLASSIFICATION
<br />OCCUPANCY A-2 (RESTAURANT) WITH NO MIXED USE OCCUPANCIES
<br />CLASSIFICATION
<br />EXISTING
<br />CONSTRUCTION VB
<br />TYPE:
<br />AREA / HEIGHT ALLOWED: ONE STORY, 40' HIGH, MAXIMUM 6,000 SQ.FT.
<br />LIMITATIONS: PROVIDED: ONE STORY, 20'-0" HIGH, 2,911 SQ.FT.
<br />EXIST. BUILDING: 2661 SF
<br />WALK IN ADDITION: 250 SF
<br />TOTAL BUILDING: 2911 SF
<br />BUILDING SUMMARY:
<br />EXISTING: 2,911 SQ.FT.
<br />THE SQUARE FOOTAGE REMAINS UNCHANGED
<br />OCCUPANCY CALCULATIONS:
<br />SQUARE OCCUPANT NUMBER OF NUMBER
<br />FLOOR USE FOOTAGE LOAD OCCUPANTS OF SEATS
<br />FACTOR
<br />1 OF: 1 DINING 1069 SQ.FT. 1:15 71 78
<br />(UNCONCENTRATED)
<br />1 OF: 1 DINING (STANDING) 33 SQ.FT. 1:5 7 -
<br />1 OF: 1 KITCHEN 815 SQ.FT. 1:200 4 -
<br />1 OF: 1 RESTROOMS 112 SQ.FT. - - -
<br />1OF: 1 UNOCCUPIED
<br />AREAS* 882 SQ.FT. - - -
<br />TOTAL NUMBER OF OCCUPANTS: 89 -
<br />* UNOCCUPIED AREAS INCLUDE: FREEZER/COOLER, WALLS, CLOSET, HALL, AND VESTIBULE
<br />** BOOTH (FIXED SEATING CALCULATIONS BASED ON LENGTH OF BOOTHS: 1 PER 24" OF BOOTH LENGTH.
<br />TOTAL INCH PER EGRESS EGRESS
<br />EGRESS CALCULATION: OCCUPANTS OCCUPANT WIDTH WIDTH
<br />REQUIRED: PROVIDED:
<br />89 0.20" 18" 108" TOTAL
<br />TOTAL EXITS REQUIRED: 2 1 TOTAL EXITS PROVIDED: 3
<br />EGRESS WIDTH PROVIDED PER EXIT: 36"
<br />THE LOSS OF ONE REQUIRED MEANS OF EGRESS SHALL NOT REDUCE THE EGRESS CAPACITY TO LESS
<br />THAN 50% OF REQUIRED.
<br />FIRE RESISTIVE
<br />REQUIREMENTS:
<br />EXTERIOR BEARING WALL ........(0 HOUR)
<br />ROOF CONSTRUCTION ....... (0 HOUR)
<br />CEILING......................................(0 HOUR)
<br />FIRE SPRINKLERS:
<br />NO
<br />FIRE ALARM:
<br />NO
<br />SYSTEM
<br />REQUIRED
<br />MAX. TRAVEL DISTANCE:
<br />200'-0"
<br />RESTROOM REQUIREMENTS:
<br />WATER CLOSETS: 1 REQUIRED FOR MALE, 1
<br />REQUIRED FOR FEMALE, (1 PROVIDED)
<br />LAVATORIES: 1 REQUIRED FOR MALE, 1 REQUIRED
<br />FOR FEMALE
<br />URINALS ........................1 PROVIDED
<br />DRINKING FOUNTAINS..... NOT REQUIRED
<br />PUBLIC ACCESS.............PROVIDED
<br />UNISEX IS PERMITTED ... NO
<br />SPECIAL INSPECTIONS:
<br />KITCHEN HOODS
<br />TYPE 1
<br />HOOD SUPPRESSION
<br />ANSUL SYSTEM
<br />SHEET INDEX
<br />Permit#:
<br />B1808-035 , n
<br />Site Address:
<br />2510 BROADWAY
<br />Owner
<br />SEAWEND LTD
<br />Tenant:
<br />WENDY'S
<br />App.Date:
<br />8/27/2018
<br />Proposed Use:
<br />COMMERCIAL
<br />Description:
<br />REPLACE UPPER METAL SIDING, INSTALL
<br />NEW BLADE
<br />Reviewed By:
<br />Date: foe1 ��
<br />?(Office Set
<br />11
<br />Job Site Set Fire/Planning Set
<br />PROJECT TEAM DIRECTORY
<br />REVISION
<br />1
<br />2
<br />3
<br />4
<br />5
<br />CLIENT
<br />WTC VENTURES
<br />G1.1
<br />COVER SHEET
<br />1820 E. CHOCTAW DRIVE
<br />LONDON, OH 43130
<br />AS1.1
<br />SITE PLAN
<br />CONTACT: DAVID ANTIS
<br />A1.1
<br />FLOOR PLAN
<br />TEL: -
<br />A1.2
<br />REFLECTED CEILING PLAN
<br />FAX: -
<br />A2.1
<br />EXTERIOR ELEVATIONS - N-S
<br />A2.2
<br />EXTERIOR ELEVATIONS - E-W
<br />A3.1
<br />WALL SECTIONS & DETAILS
<br />ARCHITECT
<br />HG KIMURA ARCHITECT PLLC
<br />A3.2
<br />WALL SECTIONS & DETAILS
<br />PO BOX 59415
<br />A3.3
<br />COOLER FOUND. PLAN; DETAILS
<br />RENTON, WA 98058
<br />A3.4
<br />SECTIONS THRU COOLER
<br />CONTACT: HOWARD KIMURA, AIA
<br />TEL: 425-271-1875
<br />A4.1
<br />SECTION DETAILS
<br />FAX:
<br />A4.2
<br />SECTION DETAILS
<br />A5.0
<br />ROOF PLAN
<br />A5.1
<br />FINISH DETAILS
<br />RESTAURANT DESIGN
<br />THE WENDY'S COMPANY
<br />ONE DAVE THOMAS BLVD.
<br />A6.1
<br />FINISH SCHEDULE
<br />DUBLIN, OH. 43017
<br />A6.2
<br />SUPPLIER LIST
<br />CONTACT: DAN BRUBAKER
<br />TEL:
<br />SP-1
<br />SPECIFICATIONS
<br />FAX:
<br />SP-2
<br />SPECIFICATIONS
<br />SP-3
<br />SPECIFICATIONS
<br />MEP ENGINEER
<br />-
<br />SP-4
<br />SPECIFICATIONS
<br />_
<br />CONTACT: -
<br />TEL: -
<br />FAX: -
<br />STRUCTURAL ENGINEER
<br />-
<br />CONTACT: -
<br />TEL: -
<br />FAX: -
<br />SITE NUMBER:
<br />1535
<br />BASE MODEL:
<br />SPEC
<br />ASSET TYPE: COMPANY/FRANCHISE
<br />CLASSIFICATION:
<br />REFRESH
<br />OWNER:
<br />OWNER NAME
<br />BASE VERSION:
<br />2016 JUL.
<br />UPGRADE CLASSIFICATION:
<br />N/A
<br />PROJECT YEAR:
<br />2016
<br />FURNITURE PACKAGE:
<br />2016
<br />DRAWING RELEASE: MARCH 2O17
<br />ti00
<br />a)
<br />N
<br />J
<br />N
<br />M
<br />N
<br />Ln O
<br />�
<br />M �
<br />a+
<br />w E
<br />.m
<br />v
<br />4)
<br />w
<br />■
<br />s
<br />v
<br />Lu
<br />■
<br />co
<br />°�' Ln
<br />O
<br />i
<br />a
<br />L
<br />00
<br />M
<br />C
<br />a� O
<br />o �
<br />Y )
<br />m U'
<br />J j
<br />N O
<br />o
<br />c
<br />PROJECT TYPE:
<br />SPEC
<br />REFRESH
<br />D
<br />�v
<br />SEP 24 2018
<br />/ Y
<br />r OF
<br />Se RFTT
<br />vies
<br />m -I-0
<br />O �
<br />O
<br />N W
<br />
|