Laserfiche WebLink
Permit#: B1910-028 <br />- Sit¢ AddrPss- ;1707 RROADWAY AVF <br />NS <br />IONS <br />Owner: NAT SQUARED LLC <br />Tenant: KFC <br />App. Date: 10/16/2019 <br />KFC Eve rett E080010■ Proposed Use: COMMERCIAL <br />Co m m e rG i a' Te n a n t I m rove m e n ROOF AREA DINING AREA REMODEL, DEMO &REVISE <br />p <br />Reviewed By Date ' <br />�'Office Set Job Site Set Fire/Planning Set <br />2702 Broadway Subject To Field Inspection <br />By The FI a Marshal � <br />EEverettXWA 98291 W roL <br />� �ro <br />• <br />N <br />•. • • •11111 L 1 <br />AB ANCHOR BOLT GA GAUGE NORTH • DO NOT SCALE DRAWINGS EVERETT PLAT OF BLK 629 D-00 - ALL LOT 28 & s1/2 OF LOT 29 OWNER: NORTHWEST RESTAURANTS INC ARCHITECTURAL <br />AC AIR CONDITIONING GALV GALVANIZED II TRUE NORTH • CONSULT THE ARCHITECT REGARDING ANY 18815 139th AVE NE, SUITE C <br />I�1 <br />ACC ACCESS GC GENERAL CONTRACTOR ERRORS, OMISSIONS OR CHANGES ON PLANS WOODINVILLE, WA 98072 A-001 COVER SHEET / VICINITY MAP /GENERAL NOTES <br />ADDL ADDITIONAL GND GROUND PROJECT BEFORE PROCEEDING WITH THE WORK. PHONE: (206) 851-5095 A-101 SITE PLAN <br />ADH ADHESIVE GR GRADE NORTH 9 COMPLY WITH ALL APPLICABLE CODES, i CONTACT: ADAM SIBERT A-201 DEMO PLAN / FLOOR PLAN / FURNITURE <br />ADJ ADJUSTABLE, ADJACENT GWB GYPSUM WALL BOARD ORDINANCES, REGULATIONS, LAWS, STANDARDS, T Y.s k 4 ARCHITECT: DIMENSIONS INC. SCHEDULE <br />PROJECT NORTH � _ �.� 3- ARCHI EC � A-202 DEMO CEILING PLAN /NEW CEILING PLAN / <br />ACST ACOUSTICAL , I( 6 CUSTOMS AND CRITERIA. .= a`l k xz" <br />I � � .. � 2820 NORTHUP WAY #140 <br />ACT ACOUSTICAL CEILING TILE HB HOSE BIB UNLESS OTHERWISE NOTED, PLAN DIMENSIONS 00439162902800 (PRIMARY ADDRESS) BELLEVUE, WA. 98004 LIGHTING SCHEDULE <br />ABV ABOVE HC HOLLOW CORE ARE TO NOMINAL SURFACE OF MASONRY, FACE OF 00439162902900 A-203 FINISH FLOOR PLAN <br />PHONE: (425) 827-9293 <br />AF ABOVE FLOOR HDR HEADER X X BUILDING SECTION CONCRETE WALLS FACE OF STUDS AT INTERIOR 00439162902600 A-204 DEMO ROOF PLAN / NEW ROOF PLAN <br />CONTACT: MIKE PERRY, AIA <br />AFF ABOVE FINISHED FLOOR HDW, HDWR HARDWARE AX•X AX.X AND EXTERIOR WALLS. A-301 DEMO ELEVATIONS / BUILDING ELEVATIONS <br />AL ALUMINUM HORIZ HORIZONTAL VERIFY DIMENSIONS BEFORE PROCEEDING WITH Q' "��000"K' <br />A-302 BUILDING ELEVATIONS/ PAINT SCHEDUL <br />��� h ��ALT ALTERNATE HT HEIGHT X WORK. (NOTIFY ARCH ITECT OF ANY r� A-401 INTERIOR ELEVATIONS <br />FULL WALL SECTIONA-610 ADA PRESCRIPTIVE STANDARDS <br />ANOD ANODIZED HTR HEATER. � X DISCREPANCIES). PROJECT LOCATION: 2702 BROADWAY <br />APT APARTMENT HVAC HEATING, VENTILATING AND • VERIFY ALL ROUGH DIMENSIONS. EVERETT, WA <br />ARCH ARCHITECT, ARCHITECTURAL AIR CONDITIONING X • VERIFY ALL SIZE AND LOCATION OF AND PROVIDE PRIMARY ZONING: UM (URBAN MIXED) <br />ATTN ATTENTION HW HOT WATER PARTIAL WALL SECTION ALL OPENING THROUGH FLOORS AND WALLS, UNDERLAY: NONE <br />AVG AVERAGE HWT HOT WATER TANK X FURRING, CURBS, ANCHORS, INSERTS AND ROUGH OCCUPANCY: A-2 <br />i — — BUCKS/BACKING FOR SURFACE -MOUNTED ITEMS. OCCUPANT LOAD: 300 <br />B/ BOTTOM (OF) INSL INSULATION X • VERIFY GRADES SHOWN ON DRAWINGS CONSTRUCTION: VB <br />BDRM, BR BEDROOM INT INTERIOR AX X I DETAIL CALLOUT e VERIFY ALL LOCATION OF ALL UTILITIES BEFORE SPRINKLERED: Y/N <br />BEL BELOW I\ �� PROCEEDING WITH WORK. <br />BTW BETWEEN JST JOIST 0 VERIFY WITH OWNER ALL LANDSCAPING TO NO FINAL <br />BLDG BUILDING JT JOINT X REMAIN, TO BE REMOVED OR TO BE RELOCATED. APPROVAL <br />BLK / BLKG BLOCK / BLOCKING ELEVATION TAG . REPETITIVE FEATURES ARE OFTEN DRAWN ONLY WATER CITY OF EVERETT <br />BLT-IN BUILT-IN KIT, KITCH KITCHEN AX.X ONCE AND SHALL BE COMPLETELY PROVIDED AS IF SEWER CITY OF EVERETT OCT 14 2022 <br />BM BEAM, BENCH MARK DRAWN IN FULL ELECTRICAL PUGET UTILITY DISTRICT <br />BOT BOTTOM LA, LARCH LANDSCAPE ARCHITECT B • COORDINATE ALL NON INDICATED OR SPECIFIED GAS PUGET SOUND ENERGY ARCHIVED <br />BS BOTH SIDES LAM LAMINATE o ITEMS WITH OWNER INCLUDING BUT NOT LIMITED <br />BSMT BASEMENT LAV LAVATORY D Ao.o A INTERIOR ELEVATION TAG TO FINISHES, COLORS, HARDWARE, FIXTURES, <br />LOC LOCATE, LOCATION C SWITCHES, OUTLETS, PHONE JACKS AND CABLE _ } <br />CAB CABINET LR LIVING ROOM OUTLETS. <br />CB CATCH BASIN LWC LIGHT WEIGHT CONCRETE • WINDOW HEADERS TO MATCH HEIGHT OF DOORS. SNOW LOAD: 25 PSF MIN (UNIFORM, <br />CIR CIRCLE ROOM NON -REDUCIBLE) <br />CL CENTER LINE MATL MATERIAL 000 ROOM TAG SEISMIC CATEGORY: D1 <br />0000 SF WIND SPEED: 110 MPH (ULTIMATE) <br />CLG CEILING MECH MECHANICAL <br />ASSUMED SOIL BEARING: 1500 PSF APPROVED <br />CLO CLOSET MTD MOUNTED FROST DEPTH: 18" (12" DECKS/PORCHES) PLANNING & CoIU{MUhliTY <br />COL COLUMN MTL METAL 1 ELEVATION KEYNOTE CRITICAL AREA: N DEVELOPMENT & COMMUNITY <br />CONIC CONCRETE <br />CPT CARPET (N) NEW HISTORIC DISTRICT: N <br />BY <br />STEEP SLOPE: N <br />CMU CONCRETE MASONRY UNIT NIC NOT IN CONTRACT X WALL AND FLOOR KEYNOTE <br />DATE I 10 <br />CONTR CONTRACTOR NO, # NUMBER CLIMATE ZONE: 4 <br />CW COLD WATER NTS NOT TO SCALE <br />DBL DOUBLE 0/ OVER0--KEYNOTE <br />DEG DEGREE OC ON CENTER x <br />THESE DOCUMENTS HAVE NOT BEEN <br />DEMO DEMOLISH OH OVERHEAD PRESCRIPTIVE 11 JURISDICTION: CITY OF EVERETT APPROVED FOR THE 'sSSNANC � RE <br />OF <br />DH DOUBLE HUNG OPNG OPENING <br />DOOR TAG o PtJBt�lC VyQRK5, MECHANICAL, , <br />DIA DIAMETER OPP OPPOSITE 001 MAX. GLAZED AREA. 30 /0 2015 INTERNATIONAL BUILDING CODE cUPPREISSION, ELECTRICAL O <br />DIM DIMENSION <br />MAX. GLAZED U-VALUE: .30 2015 INTERNATIONAL RESIDENTIAL CODE! +,It�,t?Ih' a� PERMITS• <br />DN DOWN PL PLATE, PROPERTY LINE MAX. OVERHEAD: .45 2015 INTERNATIONAL MECHANICAL CODE <br />DR DOOR PLAM POLY LAMINATE A WINDOW TAG MAX. DOOR U-VALUE: .37 2015 INTERNATIONAL FIRE CODE <br />Additional Permits Are Required <br />DS DOWN SPOUT PLY, PLYWD PLYWOOD MIN. INSULATION CEILING: R-49/R-38ci 2015 INTERNATIONAL EXISTING BUILDING CODE <br />DTL DETAIL PT PRESSURE TREATED MIN. INSULATION WALLS: R-21 2015 UNIFORM PLUMBING CODE For This Project To Include; <br />DWG DRAWING MIN. INSULATION FLOORS: R-38 2009 ICC A117.1, BARRIER -FREE STANDARD FOR (� Plumbing ® Sprinkler <br />DWP DRYWALL PAINTED QTY QUANTITY wD� FINISH TAG MIN. INSULATION SLAB ON GRADE: R-10 ACCESSIBLE AND USABLE BUILDINGS AND <br />� Mechanical Fire Alarm <br />FACILITIES <br />EA EACH RD ROOF DRAIN 2015 WSEC WASHINGTON STATE ENERGY CODE Electrical <br />EJ EXPANSION JOINT REV REVISION REVISION CLOUD <br />1 <br />EL ELEV ELEVATOR RO ROUGH OPENING ELEVATION <br />ELEC ELECTRICAL REQ D REQUIRED rtIN <br />EM 400' NEW <br />EMER EMERGENCY ..N <br />ENT, ME R ENTRY, ENTRANCE S&V STAIN AND VARNISH SPOT ELEVATION NORTH PROJECT SITE SITE AREA: ±21,000 SF 1) DEMOLISH EXISTING SIGNAGE, CEILING, <br />E EQUAL S&S STAIN AND SEAL 250' (EXIST) EXTERIOR FINISH AND FLOOR FINISH PER PLAN. Q DATE DESCRIPTION <br />Q i ' 2) REMOVE EXISTING SEATING FURNITURE <br />EXIST, (E) EXISTING SCT SECTION <br />FAR: NOT REQUIRED , 10.10.2019 DESIGN UPDATES &LIGHTING <br />IM SIMILAR (PER EMC 19.20.220) INCLUDING BOOTHS, TABLES AND CHAIRS. <br />S <br />FAR FLOOR AREA RATIO Sim SOUND TRANSMISSION — — — PROPERTY LINE 3) DEMOLISH PORTION OF EXISTING ROOF & PREP <br />26thSt o SURFACES FOR NEW FINISH. <br />FD FLOOR DRAIN COEFFICIENT LOT COVERAGE (MAX): 85 /o (±17,850 SF) <br />FE FIRE EXTINGUISHER STRL STRUCTURAL (PER EMC 19.20.230) 4) CONSTRUCT, ASSEMBLY AND/OR INSTALL NEW <br />FFE FINISH FLOOR LINE A GRID LINES SIGNAGE, CEILING, EXTERIOR FINISH AND <br />FIN FINISH TC, TOC TOP OF CURB, CONCRETE PROPOSED COVERAGE: NO CHANGE FLOOR FINISH PER PLAN. <br />_ <br />a a 5) CONSTRUCT NEW ROOF INCLUDING PARAPET <br />FIX, FIXT FIXTURE TP TOP PLATE <br />I MAX HEIGHT: 7 TO 11 FLOORS WALLS AT DEMOLISHED ROOF LOCATION. <br />FL, FLR FLOOR TW, TOW TOP OF WALL <br />FND, FNDN FOUNDATION TYP TYPICAL a (PER EMC 19.20.410) <br />FOC FACE OF CONCRETE 2 Everett Ave o <br />FOF FACE OF FINISH UNF UNFINISHED rik ELEVATION ELEVATION CALLOUT E g EXISTING HEIGHT: 1 FLOOR <br />FOS FACE OF STUD UNO, UON UNLESS NOTED OTHERWISE 000.00 � m <br />FR FIRE RESISTANT PROPOSED HEIGHT: NO CHANGE <br />FPL FP FIREPLACE W/ WITH TEXT —� TEXT LEADER <br />FDIC FURNISHED BY OWNER W/0 WITHOUT a <br />INSTALLED BY CONTRACTOR WH WATER HEATER <br />FUR, FURR FURRING WD WOOD <br />FURN FURNITURE, FURNISH WDW WINDOW California St <br />WP WATER ROOFRj <br />WR WATER RESISTANT <br />0 N <br />z OD <br />o� <br />® co N N <br />N � <br />V5REGISTERED <br />ARCHITECT <br />AEL C. PER <br />STATE OF WASHINGT <br />2 <br />�a <br />a> <br />�y <br />r <br />�a <br />CD <br />Oo <br />N <br />- _ <br />W <br />E <br />(6 <br />�o <br />�o <br />c6 <br />_ <br />}� <br />6 <br />0 <br />E <br />c m t? <br />U <br />m <br />L� <br />N <br />CVO <br />s <br />> <br />E <br />N <br />> <br />c z <br />-N <br />Wo <br />W <br />=-2o <br />U <br />zz <br />zi <br />0 <br />ZE E <br />LL <br />o § 5 <br />N§ <br />E .To <br />Job #: <br />2019-16 <br />Drawn: <br />KJH JRS <br />Checked: <br />MCP <br />Issue Date. <br />10.14.2019 <br />Submittal <br />10.15.2019 <br />10.14.2019 <br />W <br />06 <br />z <br />O <br />w <br />Cover Sheet, Project <br />N <br />Information, Vicinity <br />Map & Sheet Index <br />