My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6600 EVERGREEN WAY LUNA MEXICAN GRILL 2025-04-28
>
Address Records
>
EVERGREEN WAY
>
6600
>
LUNA MEXICAN GRILL
>
6600 EVERGREEN WAY LUNA MEXICAN GRILL 2025-04-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2025 11:23:30 AM
Creation date
3/14/2025 1:01:39 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6600
Tenant Name
LUNA MEXICAN GRILL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
217
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Commercial Kitchen Hood System <br /> EVERETT EVERETT Acceptance Test Checklist <br /> WASHINGTON INFORMATION HANDOUT C-10 4.29.2020 <br /> General <br /> This document's intent is to provide contractors with guidelines outlining the expectations and <br /> procedures for how the Everett Fire Marshal's Office will conduct an acceptance test of a commercial <br /> kitchen hood system.This document addresses the most common aspects of a commercial kitchen hood <br /> system acceptance tests, in cases where this document does not address a device or operation used <br /> with your system IFC, NFPA 17A&96, and/or Manufacturer Specifications will be used to determine <br /> testing criteria. <br /> General <br /> PASS FAIL N/A <br /> 1. Fire Alarm Tech?- In buildings that are equipped with a fire alarm system,the ❑ ❑ ❑ <br /> system installer as well as the fire alarm tech shall be present during acceptance <br /> testing. <br /> 2. Approved Plans-The installing contractor shall have the approved/stamped set of ❑ ❑ ❑ <br /> plans and the specific system installation manual located at the job site. <br /> 3. Check Plans-Verify that the suppression system, piping, and cooking equipment ❑ ❑ ❑ <br /> are the same type/style identified on the approved plans. <br /> 4. NFPA 17A Report- Prior to final approval the installing contractor shall complete, ❑ ❑ ❑ <br /> sign, and provide a copy of the NFPA 17A acceptance test report. <br /> 5. Appliance Signage-Signage shall be provided on the exhaust hood or system ❑ ❑ ❑ <br /> cabinet, indicating the type and arrangement of cooking appliances protected by <br /> the automatic fire-extinguishing system. Signage shall indicate appliances from left <br /> to right, be durable, and the size, color, and lettering that allows it to be legible <br /> from where an inspector may be standing to view the sign. <br /> Building Fire Alarm System <br /> PASS FAIL N/A <br /> 1. Fire Alarm - In buildings that are equipped with a fire alarm system,the ❑ ❑ ❑ <br /> suppression system shall be interconnected so that the actuation of the <br /> extinguishing system will sound the fire alarm and all notification devices. <br /> Fire Marshal's Office 1 425.257.8100 1 everettwa.gov/fire <br />
The URL can be used to link to this page
Your browser does not support the video tag.