� (5, � <br /> o � <br /> ID o <br /> ID <br /> Permit#: FA2407-004 z <br /> 11012024 <br /> FIRE ALARM TENANT IMPROVEMENT Site Address 0717 Everett Way STE 3 X <br /> EVERETT Applicant: Charity Odushkin a <br /> Everett Fire Dept.Permit Review Application Date:Tie Kitchen <br /> Status:Approved Description: Tie Kitchen hood to existing FACP w <br /> Reviewed By:KBrown Review Date: 07/12/2024 <br /> EVERETT WAS H I N G TO N 07/12/2024 80248 <br /> AM w <br /> ' O � <br /> Q � � <br /> N <br /> SHEET No. DESCRIPTION 'a <br /> FOR POTTER SYSTEM: Q <br /> QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT <br /> FA-01 SYSTEM INFORMATION DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED <br /> WITH DEVICES ADDRESS. F RE <br /> E(1) FACP CIONTROLR PANEL AFC-50 POTTER PROVIDED 66" A.F.F. <br /> FA-02 TYPICAL WIRING DETAIL, RISER DIAGRAM & CALCULATIONS E (EXISTING) TO TOP <br /> 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS SINGLE INPUT POTTER 4S DEEP <br /> FA-03 FLOOR PLAN - FIRE ALARM T.I DEVICE 1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. a'M MODULE PAD1oo-sIM W/ 1G RING cElLlvc <br /> 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. ®F KITCHEN HOOD EXISTING m E SUPPRESSION SYSTEM <br /> 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL U <br /> BRANCHING IS PERMISSIBLE <br /> 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL <br /> SHEET INDEX ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. <br /> 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, <br /> STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) z <br /> ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. zo <br /> 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT <br /> AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 a w <br /> wo <br /> 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, z <br /> INSTALL(1) NEW MONITOR MODULE FOR NEW KITCHEN HOOD SUPPRESSION SYSTEM. TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, <br /> AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. o <br /> 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED 0 <br /> SCOPE OF WORK DRAWINGS FOR "AS BUILT" PURPOSES. SYMBOLS LEGEND N <br /> 9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT w <br /> SHEETS AND/OR INSTALLATION INSTRUCTIONS. o <br /> r <br /> 10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS 0 <br /> MUST OMPLY WITH SPECIFICALLY SECTION <br /> R1-5.2.5 2TICLE 5 W REFERE AND 760 NCE TO DEDICATEDP BRANCH POWER aaQa <br /> SOURCES. 120voc POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT <br /> NORTHWEST ALARM MONITORING SERVICE (NWAMS) DIRECT SUPERVISION of FIRE ALARM TECHNICIAN. <br /> 1743 FIRST AVENUE SOUTH, SEATTLE,WASHINGTON 98134 11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT <br /> PHONE NUMBER: 206-622-6545 OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. O <br /> 12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE <br /> ACTIVATION DEVICE. <br /> NAME OF MONITORING CENTRAL STATION 13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. Isss <br /> 14. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY Q <br /> GENERATOR. F <br /> 15. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER w <br /> THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. 2 2 <br /> WIRE SCHEDULE AND C O N D U IT FILL CHART EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION <br /> FOR PROTECTION DURING CONSTRUCTION. ON <br /> WIRE DESIGNATION DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL O <br /> TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 = g LU <br /> SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE CHAPTER 7. _ U. <br /> 16. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT Q 2E� <br /> AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR V z w <br /> D DATA LINE ADDRESSABLE LOOP TWO #16 FPLP OTHER BACK BOXES OF DIFFERENT CIRCUITS. Q W� <br /> w <br /> 17. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND DC vW <br /> AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO g oo <br /> FINAL EQUIPMENT TRIM. Q <br /> LU <br /> CONDUIT FILL CHART 18. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A Cr <br /> OUTPUT LL <br /> No. of coNDucroRs voLrs WIRE SIZE TYPE DIMENSIONS AREA PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. <br /> 19. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE to W <br /> TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES 0Isss <br /> TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 AFTER COMPLETION OF THEIR INSTALLATION. /A <br /> TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 u, <br /> 20. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH a <br /> a <br /> CONDUIT FILL T S LOCATED. z <br /> CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE 21. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. ¢ v-i g W 8 /^ <br /> ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM 2 �a m a u J <br /> THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. 22. LOCKOUT SHALL BE INSTALLED ON THE MAIN POWER DISCONNECT ; o <br /> CIRCUIT BREAKER. NFPA 72.10.6.5.4 zz ¢ <br /> CONDUIT SIZE MAXIMUM FILL SCALE:NOT TO SCALE <br /> 23. THE MAIN POWER DISCONNECT CIRCUIT BREAKER SHALL HAVE A > Z Lu <br /> w Z w <br /> 1/2" .12 SQUARE INCH RED MARKING. NFPA 72.10.6.2.3 r U U DRAWN BY: <br /> 3/4" .21 SQUARE INCH INPUT ¢ C. ENGSTFELD <br /> 1" .34 SQUARE CH 24. MOUNT A SIGN STATING "FIRE ALARM CONTROL ROOM" ON OUTSIDE DESIGNED BY: <br /> IN <br /> L. ALLEN <br /> -1/4" .82 SQUARE INCH SQUARE INCH <br /> 1-1�2" .82 OF DOOR LEADING TO FIRE PANEL. IFC 509-1 ANYSMOKE/HEAT/PULL X X STEVE SENDLAKOWSKI DATE:07 08 2024 <br /> 2 1.34 SQUARE INCH NICET LEVEL III BACKROUND PLAN PROVIDED BY: <br /> ANY FIRE PANEL TROUBLE X CERT. #115442 EXP. 01/01/2027 JOB NUMBER:75437-1 <br /> SHEET <br /> WIRE DESIGNATION GENERAL NOTES SEQUENCE OF OPERATIONS MATRIX FA <br /> Proprietary & Confidential, Copyright 2012 b Guardian SecuritySystems, Inc. All Rights Reserved <br />