Permit#: K2409-007 �� �� �� HARBOR'S EDGE BLDG C NFPA z M <br /> Site Address: 3620 W Mukilteo BLVD Unit A <br /> Applicant: Moore Fire Protection o 1 3 D Z <br /> Application Date:09/03/2024 i SITE SPECIFICATIONS <br /> Description: Install residential Flow-through Q LL O <br /> system-Harbors Edge Bldg C - AHI: City of Everett OWNER/LESSEE: <br /> Review Date: 09/05/2024 A RELATED PERMIT: B2304-038 Sage Homes Northwest <br /> OCCUPANCY TYPE: Residential 9505-19th Ave SE,Suite 118 Q J <br /> WEST MUKILTEO BLVD. CONST.TYPE: V-B Everett,WA 98208 1-1 <br /> L STORIES: 3 (425)609-8074 <br /> EVERE_TT 97+00 98+00 99+00 N 76U+OOB017'08"E 1016.80 100+00 <br /> PARCEL: 00433600004700 <br /> Everett Fire Dept.Permit Review <br /> Status:Approved GENERAL DESCRIPTION: <br /> Reviewed By:kbrown New single family attached townhome.The typical and mirrored plans are both shown for <br /> 09/09/2024 10:56:02 reference.This submittal is for one plan-type only. <br /> AM o ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------' <br /> L------------------------- LEGAL DESCRIPTION: <br /> EDGEWATER BILK 000 D-00-LOT 47 <br /> r----------------� ° '0&` <br /> Everett Fire Dept.Notes: <br /> i(NFPA 13D) 340.17 FIRE FLOW <br /> HYD STATIC(PSI): 117 BOR STATIC(PSI): 104 <br /> •See Attached Fire Sprinkler RESIDUAL(PSI): 53 HYD ELEVATION(FT): 132.13 <br /> System Acceptance Test Checklist. i GRADE1.11-;.I CRAr)F=151 rZ GRADE= P FLOW(GPM): 1,331 MODEL REPORT DATE:02/03/23 <br /> •NFPA 13D Report-The installer shall i GRADE=152.5 GRADE=151.6 SYSTEM SPECIFICATIONS <br /> complete and sign the contractor's material e <br /> and test certificate prior to final approval of ii FizzO BUILDING CODE: 2018 IRC with WA State Amendments c <br /> the s stem. 152.g c <br /> y I Z PgD;75 SYSTEM TYPE: NFPA 13D 2019 Wet Sprinkler System •e <br /> �z n 0.8 Passive purge system without backflow preventer j <br /> -----------------J a <br /> Owp D <br /> OO � OO © O SPRINKLER COVERAGE: 256 ftz Der sprinkler listina <br /> o 1296 SF SF F 1525 SF 1220 SF 1220 Sp 122 12 F 16 SF <br /> APPROVED SPRINKLER SPACING: 16-0"max.between heads. <br /> PUBLIC WORKS DEPARTMENT PFo' FFi; F,? 153.7 FF;' <br /> F 8'-0"max.from any wall. <br /> i53.7 pAD•153'j P F''53.5 PA�151.1 PAD>i52.8 8'-0"min.between heads. <br /> BY:rHeman i PAD,1a1.7 *151.7 AD 751.5 150.8 <br /> DATE:09110/2024 FF� PF�7i <br /> CITY OF EVERETT REVIEWED FOR PERMIT PAD^150.3 PAD_160.3 PADd15p'9 Residential fast E response pendent sprinklers used throughout. N d <br /> �........... ............i ................ ........... .. ....... iff ......... 9 HAZARD CLASSIFICATION: <br /> rA <br /> 26 Residential use throughout. u° <br /> g � 863 SF <br /> PIPING DETAILS: o <br /> Blazemaster CPVC:Aboveground wet sprinkler system throughout except as noted on the F <br /> Submittal for riser detail. <br /> Bldg C Unit A only s <br /> a <br /> SUPPLY: C m n <br /> N 77°23'09" 6"circulating water main supplies 1"tap and tube to combined domestic/fire meter.1" u m` <br /> E 56.51 combined domestic/water meter supplies 1Yz"poly underground which runs to the system M Y u <br /> riser. a y e an d <br /> r............ ...... ............IN...........� f........... c a <br /> LL ar <br /> CPVC COMPATIBILITY: N <br /> J jq «O <br /> i A list of approved products for use with Blazemaster CPVC pipe is included with the product <br /> / r----------. 1----------- r--------- specifications booklet.For a complete and up-to-date product search, lease go to Y a i� <br /> FF I P P P <br /> I 75 F t FF'1�3.7 <http://www.moorefire.com/cpvc>Moore Fire Protection is not liable for damage to CPVC c d A <br /> $!1413PADa 3'j 4 1S, PAD,5 piping caused by any products which are not approved for contact with it.Information a i9 0. .g <br /> .4 i 15t.7 1'g1j'152 p 17 about products approved for contact can be found with the manufacturer. rn g sm,75a. PP 3s F t4 0 GENERAL NOTES AND LIABILITY ~ <br /> Z PAD>1514 /'ADcj5j4 Pqq 153.4 1241 SF 118 SF 1181 SF 1181 SF 5 = _' <br /> 4 't51. 480 <br /> Install CPVC piping in accordance with manufacturer's instructions and UL listing including y m <br /> but not limited to:hanging,vertical restraint,thermal expansion,chemical compatibility, ° n $ <br /> w a OH OG concealment,and protection. Horizontal CPVC pipe shall be concealed with a minimum of Z m C n <br /> V 7282 130 O 3/8"gypsum board. All CPVC pipe shall be concealed. y x u - <br /> SF 1 SF 1301 SF GRADE=153.4 GRADE=154.0 a E <br /> All system piping is to be supported per manufacturer's specifications and is to be secured <br /> PARCEL NO. SW GRADE=154.0 W to prevent lateral movement. Pipe is to be secured to prevent sprinkler head movement. <br /> 00433600004801 �rn� Moore Fire Protection's warranty of work does not cover any damage due to freeze related to a a <br /> GRADE=153.8 ^N problems. Wet piping shall be protected against temperatures below 50 degrees 999 <br /> e on with no insulation on the warm side of the a facing the heated interior. ' .. .' <br /> GRADE=154.8 ♦ 2 Fahrenheit. Insulation installed for this purpose shall be located on the cold side of the , <br /> SW GRADE=154.0 pipe Y P�P 9 a. I <br /> Coordinate with general and/or insulation contractor. All insulation to be by others. N <br /> GRADE=155.5 GRADE=155.9 a c <br /> Moore Fire Protection shall not be responsible for the ability of the structure to adequately y ;I t <br /> O O support the fire sprinkler system or any appurtenances thereof. <br /> F C, J ,� <br /> G - 1301 SF 7301 SF 1300 SF Owner is responsible for the periodic inspection,testing and maintenance of the water ;; 5 <br /> - based fire protection system(s)in accordance with the requirements of NFPA 13D Chapters� >6 <br /> 2oOIt. <br /> 12. � <br /> l <br /> y 118O SF 1181 118j 1241 P 158 3 PAD .3 PPf758.3 S h"Poi ore equivalent supply brought in b others.* <br /> jl PPF7572 FF S PF 157 PFaf�.6 PAq_156.3 AD;j56.3 PAD`156.3 Y q PPY 9 Y %... ... .. <br /> PAtl`75- PADJ.2 PAd,7556 PAD;1556 • 11/z"combination domestic/fire sprinkler shut off valve C:) <br /> M ..m•.#z <br /> i i by others.Must be located before the domestic tee. J s b x <br /> -------- ----- r •No monitoring is required. N ti <br /> i 0 a <br /> o es # v Ln U� <br /> Z ? ? ? ? �........ tic Ares - o ngtva v <br /> E 11/z"to nues to d by others An <br /> i domes sure redu Ives,water softeners, <br /> E 4 O <br /> ws 1 O leak detectors,or other devices that will deter water m i u a, m O <br /> G = 3 •Flow are to be on the domestic-only side of the tee. O w v o t in <br /> 8 0 U Brass tee top outlet to be female-threaded to d 00 U o to <br /> " n accommodate male threaded CPVC adapter m o -T <br /> G u connection. N o oo w <br /> Q 0 CI 7 J <br /> C a �o 1%"PEX to domestic by others. N 3 M O N <br /> g hh"CPVC adapter with 11/2xl CPVC reducing bushing. W LLl ry v Z " m <br /> O MFP scope of work to begin here. 2 E' o ¢ o <br /> 1"check valve. M Q d u ui <br /> w v <br /> .--i LU <br /> N 76°1648"E -- F ` ® 1"tee with flow switch wired to exterior bell by .-i IA o w a to o w <br /> 220.10 E isothers. Z M <br /> c e 1"x 1"x 1"tee with 1"drain valve piped to collection ` 1 <br /> 00 <br /> u cup attached to sanitary sewer,left by plumber and O U a+ <br /> m ®sized to accommodate the system flow demand of 27 ,^ ¢ <br /> \\ a O d gpm. 3 <br /> SITE PLAN UNDERGROUND NOTES m O 1"x 1"x 1/z"tee with 1h"x v4"bushing for pressure u <br /> 161 All underground to be by others. ° " gauge.Three way valve included for pressure gauge. W w <br /> SCALE:1/16"=1'-0" RISER SECTION 1 d <br /> ❑A Modelled hydrant Flow location SCALE:1/2"=V-0" KEYNOTE LEGEND O LU ,c <br /> ❑B 6-in circulating water main Part Tag Q U <br /> WARNING SIGN: STUB IN: <br /> v <br /> 6.3.4 A warning sign,with minimum 1/4 in.letters,shall be affixed adjacent to the main *Builder to Provide 12"x 12"block out to protect piping. O w rii <br /> ❑C Tap to 1-in combined domestic fire service(Typical for all units) shutoff valve and shall state the following: # Hydraulic Node Tag W FLUSH TEST: 'o <br /> Ee <br /> WARNING:The water system for this home supplies fire sprinklers that require certain Underground installer will be required to have a flush test completed and witnessed It m <br /> ❑D 1-in combined domestic/fire meter(Typical for all units) flows and pressures to fight a fire.Devices that restrict the flow or decrease the pressure before Moore Fire will hook up to the incoming supply.Underground installer to provide a O Reference Tag v <br /> or automatically shut off the water to the fire sprinkler system,such as water softeners, CMTC proving this test was done. LL O _ <br /> filtration systems,and automatic shutoff valves,shall not be added to this system without PASSIVE PURGE SYSTEM SPECIAL NOTES: ❑ M y# Underground Note Tag 1.1..1 � <br /> ❑E VA-in poly combined domestic/fire underground to riser location by others*(Typical for all units) a review of the fire sprinkler system by a fire protection specialist. This is aFlow-through("passive purge")system.A 1h"female adapter will be left at the 1:2 f <br /> remote toilet location.Plumber is to connect from adapter to toilet. <br /> Do not remove this sign. �# Remote Area Tag Q o <br /> ❑F Riser location-see this page for detail(Typical for all units) T ^� <br /> y io <br /> M <br />