Laserfiche WebLink
convergjnt' <br /> convergnit 450 Shattuck Avenue South,Renton,Washington 98057 <br /> Phone:425-272-2250 Fax:425-251-0949 <br /> This dowment and the information/depidions confainetl/shown <br /> is the exclusive property of Convergint Technologies LLC and shall <br /> be handled as propn,hUy and wnfdential information and must be <br /> returned upon request.This document cannot be reproduced by any <br /> nheans without the wditen authorization of Convergint Technologies U.C. <br /> J A C K S O N ES Permit#: FA2402-018 <br /> Site Address: 3700 Federal Ave Portable 2 <br /> Applicant: Curtis Nasalka <br /> PORTABLES P 1 -P 7 Application Date 0 22 2 0 2 4 <br /> Description: Providing fire alarm for classroom portable#2 <br /> Review Date: 0212818/2024 <br /> EVE <br /> TT <br /> 3700 FEDERAL AVE, EVERETT, WA 98201 Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 02/28/2024 2:23:49 <br /> SYMBOL LEGEND SCOPE OF WORK WIRE LEGEND MOUNTING HEIGHTS PM <br /> SYM DESCRIPTION MODEL# MANUFACTURER BACK BOX THIS SCOPE OF WORK INCLUDES: ALL WIRING AND INSTALLATION METHODS SHALL BE IN COMPLIANCE WITH CURRENT RELEVANT <br /> NAC NATIONAL AND LOCAL ELECTRICAL CODE ARTICLES AND RELATED SECTION CODE REQUIREMENTS. A/C SUPPLY DIFFUSER <br /> SIGA-CCiS MODULE 0 <br /> NAcxx POWER SUPPLY-6A EBPS6A EST INCLUDED-17"H X 13"W X 3.5"D FIRE ALARM WORK RELATED TO THE RELOCATION OF 4 EXISTING PORTABLES AND THE ADDITION IG OF 3 NEW PORTABLES. WIRING INSTALLATION NOTES: CEILING MOUNTED FLUORESCENT LIGHT <br /> EXISTING PORTABLES TO RETAIN ALL EXISTING FIRE ALARM DEVICES.NEW CONNECTION TO MAIN •LABEL ALL ZONE WIRES WITH ZONE NUMBER TAG AND DESCRIPTION. SMOKE/HEAT <br /> FaTcxx FIRE ALARM TERMINAL CABINET BY OTHERS BY OTHERS - PANEL PROVIDED. 'LABEL ALL SIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT NUMBER TAG AND DESCRIPTION. DETECTOR TYP. 3'(MIN) <br /> NEW PORTABLES PROVIDED WITH HORNSTROBE NOTIFICATION DEVICES AND FIRE DETECTION.A 'LABEL ALL NETWORK,ANNUNCIATOR AND 1/0 CONTROL CIRCUIT WIRING WITH CIRCUIT NUMBER NOTE:DIMENSIONS SHOWN <br /> DOUBLE ACTION PULL STATION A�O­F <br /> HE CLOSEST <br /> ❑F SIGA-278 EST SINGLE GANG,2-1/2"DEEP NEW POWER SUPPLY IS PROVIDED TO SUPPORT NEW NOTIFICATION DEVICES. TAG AND DESCRIPTION. EDGEHE DETEOTOR <br /> STANDARD CEILING <br /> 'VERIFY WITH OWNER AND GENERAL CONTRACTOR THAT OPEN CABLE IS ALLOWED ON SPECIFIC <br /> ADDRESSABLE FIXED HEAT DESIGN CRITERIA APPLICABLE STANDARDS AND GUIDANCE: SITE.(FPL,FPLP,RISER,OR 2 HOUR RATED) <br /> Q SIGA-HFD EST 4"OCTAGON BOX,1-1/2'DEEP <br /> SIGA-SB4-STANDARD BASE NFPA 72,2016 EDITION •WHERE REQUIRED,OUR DRAWINGS WILL NOTE WIRE OR PATHWAY REQUIRING SURVIVABILITY. <br /> 2018 INTERNATIONAL BUILDING CODES WITH EVERETT AMENDMENTS SUBSTITUTE THE RELEVANT CABLE WITH AN EQUIVALENT CABLE COMPATIBLE WITH THE MEANS OF 3' <br /> 4"SQUARE BOX,1-1/2"DEEP,SINGLE GANG ONLY DEVICES <br /> 8 VISUAL 12" <br /> }( REMOTE ALARM LED-CEILING SIGA-LED EST COVER 2018 MECHANICAL CODE SURVIVABILITY.THIS OFTEN INCLUDES;CI-C OR Cl CABLE(CIRCUIT INTEGRITY),CONCRETE ONLY DEVICES MAX <br /> R 2020 NATIONAL ELECTRICAL CODE WITH EVERETT AMENDMENTS ENCASEMENT OR OTHER MEANS AS APPROVED BY THE AHJ.REFER TO NFPA 72 FOR FURTHER S <br /> STANDARD ADDRESSABLE SMOKE INFORMATION. <br /> 0 SIGA-SB4-STANDARD BASE SIGA-OSD EST 4"OCTAGON BOX,1-1/2"DEEP OCCUPANCY/USE CLASSIFICATIONS: FIRE ALARM REMOTE MANUAL PULL <br /> HORN/STROBE-WALL MOUNT B-BUSINESS NON PLENUM: SINGLE COND.: PLENUM RATED: FIRE ALARM ANNUNCIATOR STATION <br /> COLOR:WHITE,MARKING:FIRE,LENS:CLEAR 757-4A-TW EST 4"SQUARE S-2-STORAGE CIRCUIT DESCRIPTION (FPLR,FPL) (THHN,TFFN) (FPLP) CONTROL PANEL <br /> HORN/STROBE-WALL MOUNT 4"SQUARE W/EST MODEL"GRSW-10" A ZONE/INPUT CIRCUIT BELDEN 5220UL J <br /> EllG4AVWF EST DOCUMENTATION AVAILABLE TO CONVERGINT TECHNOLOGIES (2)#16AWG BELDEN 6220UL <br /> COLOR:WHITE,MARKING:FIRE,LENS:CLEAR WIRING PLATE 80"MIN.TO BOTTOM <br /> PORTABLE LIGHTING AND FIRE ALARM FLOOR PLANS BY DYKEMAN ARCHITECTURE. 2 COND.16 AWG [3.S5Q][24pF/FTJ [3.85Q][37pF/FT] OF LENS 4 <br /> DATED 01/16/2024. C NAC CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 6120UL OR ?+ <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.43R][37pF/FT] 96"MAX.TO TOP <br /> O w <br /> D MASS.NOTIFICATION NAC CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 6120UL OF LENS 72"AFF 60"AFF z <br /> 2 COND.14 AWG r2.430][23pF/FT] [2.43Q][37pF/FT] 48 MAX(ADA) <br /> E DOOR HOLDER/CONTROL CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 6120UL 42"MIN/54"MAX(NFPA) <br /> CONTACT INFORMATION 2COND.I4 AWG [2.430][23pF/FT] [2.43Q][37pF/FT] <br /> FINIS <br /> F FAN/HVAC SHUTDOWN BELDEN 5120UL (2)#14 AWG BELDEN 6120UL HED FLOOR <br /> PROJECT MANAGER FIRE ALARM DESIGNER 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] 'DEVICES SHOWN DEPICT DEVICE TYPES ONLY. <br /> CURTIS NASATKA JACOB USHER G FUTURE ADA NAC BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> 206-406-3499 CIRCUIT 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> CURTIS.NASATKACONVERGINT.COM JACOB.USHER@CONVERGINT.COM <br /> SALES REPRESENTATIVE H PHONE CIRCUIT BELDEN 5220FL N/A BELDEN 6220FL <br /> PETER CAVALIERE 2 COND.16 AWG SHIELDED [3.90][65.5pF/FT] [3.850][77pF/FT] <br /> 206_483-5490 <br /> PETE.CAVALIERE@CONVERGINT.COM J SPEAKER CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> 2 COND.16 AWG [3.85Q][24pF/FT] [3.85Q][37pF]FTJ <br /> L ELEVATOR CONTROL BELDEN 5120UL (2)#14 AWG BELDEN 612OUL _ <br /> GENERAL NOTES 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> M AUDIO RISER BELDEN 5220FL N/A BELDEN 6220FL <br /> 2 COND.16 AWG SHIELDED [3.90][65.5pF/FT] [3.855)][77pF/FT] <br /> THE FOLLOWING NOTES ARE INTENDED TO BE GENERAL IN NATURE AND ARE NOT SPECIFIC TO EACH N NETWORK COMMUNICATIONS BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> PROJECT.THESE NOTES ARE TO BE FOLLOWED WHERE APPLICABLE TO INDIVIDUAL PROJECTS AND 2 COND.16 AWG [3.850][24pF/FT] [3.85Q][37pF/FT] <br /> SHOULD NOT BE TAKEN AS SCOPE OR DIRECTION WHERE THEY CONFLICT WITH INFORMATION FOUND <br /> ELSEWHERE IN THIS DRAWING SET. P 24VDC AUX.POWER BELDEN 5120UL (2)#14 AWG BELDEN 6120UL <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> 1. ALL WIRE AND CONDUIT SHALL BE INSTALLED IN ACCORDANCE WITH PLANS AND Q VESDA NET BELDEN 9841 N/A BELDEN 89841 <br /> SPECIFICATIONS AND SHALL MEET ALL APPLICABLE CODES. 2 COND.22 AWG [24Q][12.8pF/FT] [240][12pF/FT] <br /> 2. ALL WIRE AND CABLE SHALL BE RATED FOR FIRE ALARM USE PER THE LATEST REVISIONS OF R REMOTE LED CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> THE NATIONAL ELECTRICAL CODE(NEC)SECTION 760.THIS IS A POWER LIMITED FIRE ALARM 2 COND.16 AWG [3.85D][24pF/FT] [3.850][37pF/FT] <br /> SYSTEM.ALL CABLE MUST BE MARKED FPL,FPLP,FPLR OR Cl.FURTHER NEC,REQUIRES ALL <br /> WIRE BE RATED FOR THE ENVIRONMENT FOR WHICH IT IS INSTALLED.ANY REFERENCES TO S ADDRESSABLE DATA SLC LOOP BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> WIRE DESIGNATIONS ASSUME ELECTRICAL CONTRACTOR WILL SUBSTITUTE APPROPRIATE 2 COND.16 AWG [3.85Q][24pF/FT] [3.850][37pF/FT] <br /> WIRE TO MEET CODE. <br /> T1 ANALOG TWO-WAY COMM.CABLE N/A RATH RP66010001 <br /> 3. ALL CONDUCTORS SHALL TEST FREE OF GROUNDS AND SHORTS BEFORE MAKING ANY 2 COND.18 AWG WA [2-HOUR CIC] <br /> CONNECTION TO THE FIRE ALARM CONTROL PANEL. T2 ANALOG TWO-WAY COMM.CABLE RATH 66120 N/A N/A <br /> 4. TO RETAIN WARRANTY,THE FIRE ALARM EQUIPMENT MUST BE POWERED UP UNDER THE 2 COND.18 AWG [2-HOUR] DESIGNER OF RECORD <br /> SUPERVISION OF A QUALIFIED MANUFACTURERS TECHNICIAN. TP ANALOG TWO-WAY POWER CABLE N/A RATH R66010001 JACOB USHER <br /> 2 COND.18 AWG N/A [2-HOUR CIO] NICET III <br /> 5. THE INSTALLING ELECTRICAL CONTRACTOR SHALL COORDINATE ALL FIELD CHANGES WITH THE ` FIRE ALARM SYSTEMS <br /> FIRE ALARM CONTRACTOR.THIS INCLUDES CHANGES IN DEVICES,WIRE,CONDUIT RUNS AND U SUPPRESSION RELEASING CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 6120UL <br /> OPERATION OF THE SYSTEM.FIRE ALARM CONTRACTOR SHALL NOT BE HELD RESPONSIBLE 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> 1102 <br /> FOR UNDOCUMENTED CHANGES OR THE RESULTS OF THOSE CHANGES. W SINGLE MODE FIBER NETWORK BUDGET SMXL02/SMXHI2:15/25 dBm �l ML_ -ot-zozs <br /> H. <br /> 6. FIRE ALARM NOTIFICATION DEVICES SHALL BE AUDIBLE THROUGHOUT THE SPACE AND SHALL 8.3pSM CONNECTOR:DUPLEX SC soft Corporation © 2023 TornTorr '11 ,Y• PL�EVISIT,�`I�ANICE G <br /> HAVE A SOUND PRESSURE LEVEL NOT LESS THAN 15db ABOVE THE AVERAGE AMBIENT SOUND X MULTIMODE FIBER NETWORK BUDGET MMXVR:10 dB. <br /> LEVEL OR 5db ABOVE THE MAXIMUM SOUND LEVEL,MEASURED AT 5'0"ABOVE THE FINISHED 50/125p,62.5/125p OR 100/140p MM CONNECTOR:ST (��G <br /> FLOOR. <br /> Y TWO-WAY COMMUNICATIONS BELDEN1583A N/A BELDENi585A VICINITY MAP <br /> 7. MAIN BUILDING FIRE ALARM&SUPPRESSION SYSTEMS SHALL BE CLASS"B"WIRING. CAT5E-(4)PAIR 22 AWG <br /> PRE-ACTION&DELUGE ALARM SYSTEMS SHALL BE CLASS"A"WIRING.CLASS"A"APPLICATIONS Z FIRE/SMOKE DAMPER INTERFACE BELDEN 5120UL (2)#14 AWG BELDEN 6120UL ,'v <br /> SHALL MAINTAIN A MINIMUM SEPARATION OF 48 INCHES HORIZONTALLY&12 INCHES 2 COND.14 AWG BELD[2.43 ][23pF/FT] [2.43R][37pF/FT] <br /> VERTICALLY BETWEEN OUTGOING AND RETURN CIRCUITS. <br /> 8. ALL PULL STATIONS AND NOTIFICATION DEVICES SHALL BE MOUNTED AT HEIGHTS SPECIFIED NOTE:ALL LISTED RESISTANCE AND CAPACITANCE ARE CONDUCTOR TO CONDUCTOR.ALL <br /> PER NFPA 72 AND ADA REQUIREMENTS. RESISTANCE VALUES ARE PER 1000 FEET. ABBREVIATIONS <br /> 9. ALL DETECTOR SPACING SHALL BE PER NFPA 72&LOCAL CODES. AC-ABOVE CEILING FSD-FIRE SMOKE DAMPER(THIRD PARTY) <br /> SHEET LIST TABLE AFF-ABOVE FINISHED FLOOR HVAC-HEATING,VENTILATION,AND AIR <br /> 10. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ROUGH-IN LOCATIONS WITH OTHER ADA-AMERICAN DISABILITIES ACT CONDITIONING(THIRD PARTY) <br /> TRADES. SHEET NUMBER SHEET TITLE AHJ-AUTHORITY HAVING JURISDICTION LA-LOW AIR(THIRD PARTY) <br /> FA-0-1 COVER SHEET AHU-AIR HANDLING UNIT(THIRD PARTY) N/A-NOT APPLICABLE <br /> FA-0-2 NOTES ASO-ASPIRATION SMOKE DETECTION NAC-NOTIFICATION APPLIANCE CIRCUIT <br /> 11. ALL FIRE ALARM DEVICES SHALL BE SECURELY FASTENED TO WALLS OR CEILINGS. FA-1-1 LEVEL 1-FLOOR PLAN CD-CANDELA(EX.15CD) NFPA-NATIONAL FIRE PROTECTION ASSOCIATION <br /> FA-2-1 TYPICAL RISER CIS-COMMON INTELLIGIBILITY SCALE NIC-NOT IN CONTRACT <br /> 12. SMOKE DETECTORS SHALL NOT BE LOCATED CLOSER THAN 36"TO ANY AIR REGISTER OR FA-4-1 DEVICE DETAILS <br /> DIFFUSER. FA-5-1 I DH-DOOR HOLDER(THIRD PARTY UNO) NITS-NOT TO SCALE <br /> EF-EXHAUST FAN(THIRD PARTY) PS-POWER SUPPLY <br /> 13. HEAT DETECTORS SHALL NOT BE LOCATED CLOSER THAN 36"TO ANY AIR REGISTER OR ELEV-ELEVATOR(THIRD PARTY) RTU-ROOF TOP UNIT(THIRD PARTY) <br /> EOL-END OF LINE SLC-SIGNALING LINE CIRCUIT <br /> DIFFUSER. EPF-ELEVATOR PRESSURIZATION FAN(THIRD PARTY) SPF-STAIR PRESSURIZATION FAN(THIRD PARTY) <br /> 14. PER NFPA 72,CHAPTER 17;SMOKE DETECTORS INSTALLED PRIOR TO FINAL CLEAN MUST BE FA-FIRE ALARM STI-SPEECH TRANSMISSION INDEX <br /> CLEANED AND VERIFIED TO BE OPERATING IN ACCORDANCE WITH THE LISTED SENSITIVITY,OR FAA-FIRE ALARM ANNUNCIATOR TYP-TYPICAL <br /> THEY SHALL BE REPLACED PRIOR TO THE FINAL COMMISSIONING OF THE SYSTEM. FA -FIRE ALARM CONTROL PANEL UNO-UNLESS NOTED OTHERWISE <br /> CONVERGINT BEARS NO RESPONSIBILITY FOR LABOR OR MATERIAL ASSOCIATED WITH FACU-FIRE ALARM CONTROL UNIT VAV-VARIABLE AIR VOLUME(THIRD PARTY) <br /> CLEANING,SENSITIVITY TESTING OR REPLACEMENT OF SMOKE DETECTORS INSTALLED PRIOR FATC-FIRE ALARM TERMINAL CABINET VFD-VARIABLE FREQUENCY DRIVE(THIRD PARTY) <br /> FBO-FURNISHED BY OTHERS W/-WITH <br /> TO FINAL CLEANING. FCU-FAN COIL UNIT(THIRD PARTY) W-WATT(EX.1/2W) <br /> 15. HEAT DETECTORS SHALL NOT BE LOCATED CLOSER THAN 36"TO ANY HEAT GENERATING FFT-FIREFIGHTER'S TELEPHONE WP-WEATHERPROOF <br /> DEVICE(FUSES,BOILERS,WATER HEATERS,ETC.)IN MECHANICAL ROOMS. FM-FACTORY MUTUAL XP-EXPLOSION PROOF <br /> REV JOSH-DESCRIPDON DATE <br /> 16. HEAT DETECTORS SHALL NOT BE LOCATED CLOSER THAN 18"TO ANY PART OF ANY LIGHT FLOOR PLAN KEY ISSUED FOR PERMUT °y° 21 <br /> FIXTURE. <br /> DEVICE ADDRESS KEY DETAIL BUBBLE KEY <br /> 17. HEAT DETECTORS SHALL BE MOUNTED WITHIN 24"OF A SPRINKLER HEAD WHEN USED FOR <br /> ELEVATOR SHUNT TRIP IN ELEVATOR MACHINE ROOMS&SHAFTS. DETAIL NUMBER <br /> FIRE ALARM PANEL# <br /> 18. INITIATING AND SIGNALING CIRCUITS MAY BE RUN IN SAME CONDUIT. 0 DEVICE ADDRESS 4DETAIL <br /> 19. ALL CONDUCTORS SHALL BE LABELED BY ZONE OR SLC LOOP NUMBER. x-x-xxxx-x LOCATION(-=SAME SHEET) <br /> p 20. THESE DRAWINGS ARE INTENDED TO SHOW PROJECT SPECIFIC PANELS,DEVICES AND WIRING DATA CARD ISOLATED AB2RANCH <br /> U DEPICTED DIAGRAMMATICALLY.WIRING SHOWN IS NOT INTENDED TO DEPICT RACEWAY OR LOGICAL ADDRESS TER( ) aaON W. <br /> CI PATHWAY LOCATIONS.DEVICE AND PANEL LOCATIONS SHALL BE COORDINATED BY INSTALLING PROJECT DESIGNER: JACOB U. <br /> Ud CONTRACTOR AS PART OF THE CONSTRUCTION PROCESS. <br /> NOTIFICATION DEVICE CIRCUIT KEY DRAWING SHEET INDEX KEY <br /> U 21, ALL REFERENCES TO INTERNATIONAL BUILDING CODE(IBC)ARE FROM THE 2015 EDITION.ALL Jwstes°ATE <br /> U) REFERENCES TO NFPA 72 ARE FROM THE 2013 EDITION AS CURRENTLY ADOPTED BY IBC.THE SPEAKER CIRCUIT NUMBER FIRE ALARM i-LEVEL/FLOOR/AREA <br /> ¢ ADOPTED VERSION FOR THE PROJECT JURISDICTION MAY BE DIFFERENT AND UPON REQUEST CIRCUIT <br /> rA CONVERGINT WILL PROVIDE UPDATED REFERENCE SECTIONS TO MATCH ADOPTED VERSION. CIRCUIT NUMBER SP-X FA-x-XX JACKSON ES <br /> F THE SCOPE SECTION OF OUR DRAWINGS WILL PROVIDE THE VERSION REFERENCED FOR THE POWER SUPPLY � \ PORTABLES P1-P7 <br /> FIRE ALARM DESIGN. SUFFIX- 0=COVER SHEET <br /> v N x 1=FLOOR PLANS 3700 FEDERAL AVE <br /> x 22, AS THE FIRE ALARM VENDOR UTILIZED FOR THIS BUILDING,NFPA 72 REQUIRES WE KEEP `\ 2-RISER DIAGRAMS EVERETT,WA 98201 <br /> ACCURATE RECORD DRAWING INFORMATION.AS SUCH,IT IS NECESSARY THAT WE DEPICT `LOGICAL DEVICE NUMBER 3=FIRE PANEL DETAILS <br /> EXISTING DEVICES AND WIRING IN ADDITION TO THOSE COMPONENTS ASSOCIATED WITH YOUR 4 5-DEVICE DETAILS <br /> =CALCULATIONS <br /> � SCOPE WHERE APPLICABLE.UNLESS OTHERWISE NOTED,IT IS ASSUMED EXISTING 6=2-WAY COMMUNICATION <br /> Z NEW VS <br /> SCOPEENTS WILL REMAIN UN-DISTURBED BY YOUR EXSTNG,WEWILLTURNEXISTINGCO PONENTSTOA LIGHTER SHADE.REMOVAL F COVER SHEET <br /> U) THE EXISTING DEVICES AND WIRING MAY OTHERWISE IMPACT THE CONTEXT OF THE <br /> COMPLETE,CODE REQUIRED FIRE ALARM SYSTEM,THEREFORE THEY CANNOT BE OMITTED <br /> Z FROM OUR DRAWING PACKAGE. FIRE ALARM SYSTEM <br /> wTNG. <br /> o FA-0-1 <br /> LL <br />