Site Address: 3702 W Mukilteo Blvd Unit B �� �� �� HARBOR'S EDGE BLDG D NFPA z M <br /> Applicant: Matthew Steele r -. . -: . <br /> Application Date:06/21/2024 0 1 3 D Z LL <br /> Description: Install new residentialflow-throughsystemintownhouse 1 SITE SPECIFICATIONS LL O <br /> Review Date: 06/24/2024 ?) <br /> - AHI: City of Everett OWNER/LESSEE: Q <br /> A RELATED PERMIT: B2304-047 Sage Homes Northwest <br /> OCCUPANCY TYPE: Residential 9505-19th Ave SE,Suite 118 Q J <br /> WEST MUKILTEO BLVD. CONST.TYPE: V-B Everett,WA 98208 1-1 <br /> EVERETT 97+00 98+00 99+00 N76U+OOB017'08"E 1016.80 100+00 STORIES: 3 (425)609-8074 <br /> PARCEL: 00433600004700 <br /> Everett Fire Dept.Permit Review <br /> Status:Approved GENERAL DESCRIPTION: <br /> Reviewed By:KBrown New single family attached townhome.The typical and mirrored plans are both shown for <br /> 06/24/2024 2:00:21 reference.This submittal is for one plan-type only. <br /> ------------------------- LEGAL DESCRIPTION: <br /> EDGEWATER BLK 000 D-00-LOT 47 <br /> APPROVED <br /> PUBLIC WORKS DEPARTMENT ° FIRE FLOW <br /> 34017 <br /> BY:THerman . <br /> HYD STATIC(PSI): 117 BOR STATIC(PSI): 104 <br /> DATE:0612512024 <br /> RESIDUAL(PSI): 53 HYD ELEVATION(FT): 132.13 <br /> CITY OF EVERETT REVIEWED FOR PERMIT FLOW(GPM): 1,331 MODEL REPORT DATE:02/03/23 <br /> GRADE1.1,1-;.I rRAnF=151 rZ GRADE= P <br /> GRADE=152.5 GRADE=151.6 SYSTEM SPECIFICATIONS <br /> FF, O BUILDING CODE: 2018 IRC with WA State Amendments <br /> Z PAD,1528 SYSTEM TYPE: NFPA 13D 2019 Wet Sprinkler System 0 <br /> 150.8 Passive purge system without backflow preventer '> <br /> O <br /> O O © AO SPRINKLER COVERAGE: 256 ftz Der sprinkler listina <br /> wp D <br /> o N 1296 SF 1221 SF 1220 SF 1525 SF 1$25 SF 1220 SF 1220 SF 1220 SF 1216 SF <br /> SPRINKLER SPACING: 16-0"max.between heads. <br /> FFc' PFi 1 FF,i pF 153.1 FFc' 8'-0"max.from any wall. <br /> ' ? PAD;15j� PAD*15j.j PAD;;5j.5 AD�151.1 PADo150.8 8'-0"min.between heads. <br /> PAD`750.3 PAD>760.3 1'ADd15p'9 Residential fast E response pendent sprinklers used throughout. N d <br /> �........... ............i i.............. 4ff ......... �........... ............ .......... ............. 9 HAZARD CLASSIFICATION: <br /> y <br /> 26 Residential use throughout. u° <br /> g 663 SF <br /> PIPING DETAILS: o <br /> Blazemaster CPVC:Aboveground wet sprinkler system throughout except as noted on the F <br /> riser detail. vi <br /> / <br /> a SUPPLY: C m n <br /> N 77°23'09" 6"circulating water main supplies 1"tap and tube to combined domestic/fire meter.1" i%m` <br /> E 56.51 combined domestic/water meter supplies 1Yz"poly underground which runs to the system M Y u <br /> riser. a y e an d <br /> ............ ...... r........... ..........-� ............ u. a <br /> � MiL <br /> CPVC COMPATIBILITY: N <br /> J Iq «O <br /> i A list of approved products for use with Blazemaster CPVC pipe is included with the product <br /> / r----------. 1-----------" r--------- i i i specifications booklet.For a complete and up-to-date product search, lease go to 01 `u i� <br /> / I P P P ,- <br /> I FF'75 F I FF'1�3.7 PFi 153.g <http://www.moorefire.com/cpvc>Moore Fire Protection is not liable for damage to CPVC c u °L <br /> I I I $!153PqD_ 3, PF=1$4 0 PADotSj Ap=75j piping caused by any products which are not approved for contact with it.Informationo. .g <br /> 4i 151.7ADe152p 7 r- 3 about products approved for contact can be found with the manufacturer. yFF1753. AF 5 F�15 S 116 GENERAL NOTES AND LIABILITY <br /> Z PA 4 PADcI 14 PA 3.4 1247 118 SF 1181 SF 1181 SF 1 SF o .c <br /> 1 4 151.4 q-151.4 SF 4ti v <br /> Install CPVC piping in accordance with manufacturer's instructions and UL listing including y <br /> N a but not limited to:hanging,vertical restraint,thermal expansion,chemical compatibility, ° n a <br /> w a O O concealment,and protection. Horizontal CPVC pipe shall be concealed with a minimum of 2 m C n <br /> V 1282 130 O 3/8"gypsum board. All CPVC pipe shall be concealed. <br /> SF 1 SF 1301 SP GRADE=153.4 GRADE=154.0 > a <br /> All system piping is to be supported per manufacturer's specifications and is to be secured <br /> PARCEL NO. SW GRADE=154.0 W to prevent lateral movement. Pipe is to be secured to prevent sprinkler head movement. r•Y '^ �'d <br /> F'>A <br /> 00433600004801 �rn� Moore Fire Protection's warranty of work does not cover any damage due to freeze related o;0. am <br /> - GRADE=153.8 ^N problems. Wet piping shall be protected against temperatures below 50 degrees <br /> e only with no insulation on the warm side of the a facing the heated interior. r .. .' <br /> SW GRADE=154.0 GRADE=154.8 ♦ 2 Fahrenheit. Insulation installed for this purpose shall be located on the cold side of the , <br /> Submittal for pipe Y .p g I "' ' <br /> Bldg D Unit B Coordinate with general and/or insulation contractor. All insulation to be by others. N <br /> l =155 GRADE=155.9 a <br /> Moore Fire Protection shall not be responsible for the ability of the structure to adequately cy I C t C <br /> - O support the fire sprinkler system or any appurtenances thereof. u ( 1 <br /> J <br /> G - 1301 SF 7301 SF 1300 O SF Owner is responsible for the periodic inspection,testing and maintenance of the water ;; 5 <br /> - based fire protection system(s)in accordance with the requirements of NFPA 13D Chapter <br /> �a O O O 12. � <br /> y 1180 SF 118j 1241 F 1583 PFF` 56.3 FF758.3 Srh"Polyore equivalent supply brought in b others.* <br /> m FFa15 FF 1 F,`SF PAdz 156.3 AD;�56.3 PADr756.3 q PPY 9 Y %... ... .. <br /> PA�y, �2 Pq 5j6 PAD, -6 i i I • S1h"combination domestic/fire sprinkler shut off valve O m ..�•.�*a <br /> i'155.2 '155.6 16Q6 i i by others.Must be located before the domestic tee. O X <br /> I' -------- ----- r •No monitoring is required. N J <br /> 0 LL <br /> i : O es # N (A U w <br /> Z :: �.............• ticpressure-reducingo domestic <br /> softeners, v - m co' <br /> wsG i........... ............i i........... ............i i = e ak detectors,o other devices that II deter water m i u <br /> 0 <br /> O 9 1 <br /> 3 •Flow are to be on the domestic-only side of the tee. O w v o t n <br /> 8 U Brass tee top outlet to be female-threaded to d r-I U r= o to <br /> " O n accommodate male threaded CPVC adapter � m o v <br /> connection. N oo w <br /> O.i Q 0 Ci 7 J <br /> C a 1%"PEX to domestic by others. N 3 M O N <br /> g hh"CPVC adapter with 11/2xl CPVC reducing bushing. LU LLi ;,� v Z <br /> O 01 <br /> MFP scope of work to begin here. 2 E o ¢ o <br /> 1"check valve. V)Q d u ui <br /> w v <br /> r-I LU <br /> N 76°1648"E -- r ` ® 1"tee with flow switch wired to exterior bell by .--I tD 0. a N tj w <br /> others. <br /> 220.10 e n Z o <br /> c e 1"x 1"x 1"tee with 1"drain valve piped to collection ` N <br /> u cup attached to sanitary sewer,left by plumber and O o+ <br /> m ®sized to accommodate the system flow demand of 27 r^ 3 <br /> \\ a O d .�Si gpm. V <br /> SITE PLAN UNDERGROUND NOTES m O 1"x 1"x 1/2"tee with 1h"x v4"bushing for pressure U <br /> SCALE:1/16"=1'-0" 16 All underground to be by others. ° .r gauge.Three way valve included for pressure gauge. LW w <br /> ❑A Modelled hydrant Flow location RISER SECTION KEYNOTE LEGEND r LU r <br /> SCALE:1/2"=1'-0" O r n <br /> ❑B 6-in circulating water main • Part Tag 1 VQ p <br /> WARNING SIGN: STUB IN: <br /> v <br /> 6.3.4 A warning sign,with minimum 1/4 in.letters,shall be affixed adjacent to the main *Builder to Provide 12"x 12"block out to protect piping. O w m <br /> ❑C Tap to 1-in combined domestic/fire fire service T ) shutoff valve and shall state the following: # Hydraulic Node Tag <br /> p U (Typical for all units 9: FLUSH TEST: 'a <br /> WARNING:The water system for this home supplies fire sprinklers that require certain *Underground installer will be required to have a flush test completed and witnessed Op <br /> ❑D 1-in combined domestic/fire meter(Typical for all units) flows and pressures to fight a fire.Devices that restrict the flow or decrease the pressure before Moore Fire will hook up to the incoming supply.Underground installer to provide a O Reference Tag I' <br /> or automatically shut off the water to the fire sprinkler system,such as water softeners, CMTC proving this test was done. LL O _ <br /> filtration systems,and automatic shutoff valves,shall not be added to this system without PASSIVE PURGE SYSTEM SPECIAL NOTES: x <br /> ❑# Underground Note Tag CIO <br /> ❑E lYz-in poly combined domestic/fire underground to riser location by others*(Typical for all units) a review of the fire sprinkler system by a fire protection specialist. This is aFlow-through("passive purge")system.A 1h left"female adapter will be le at the E� <br /> remote toilet location.Plumber is to connect from adapter to toilet. 3: <br /> Do not remove this sign. �# Remote Area Tag Q N <br /> ❑F Riser location-see this page for detail(Typical for all units) = o <br /> n <br /> M <br />