Laserfiche WebLink
HARBOR'S EDGE UNIT 9 NFPA z M <br /> 1 o SITE SPECIFICATIONS 13D IZI a- LL <br /> Q � O <br /> - AHI: City of Everett OWNER/LESSEE: <br /> A RELATED PERMIT: N/A Sage Homes Northwest <br /> OCCUPANCY TYPE: Residential 9505-19th Ave SE,Suite 118 Q J <br /> WEST MUKILTEO BLVD. CONST.TYPE: V-B Everett,WA 98208 1-1 <br /> 97+00 98+00 99+00 N 76U+OOB017'08"E 1016.80 100+00 STORIES: 3 (425)609-8074 <br /> PARCEL: 00433600004700 <br /> Submittal forGENERAL DESCRIPTION: <br /> Unit 9 Only New single family attached townhome.The typical and mirrored plans are both shown for <br /> reference.This submittal is for one plan-type only. <br /> ------------------------- LEGAL DESCRIPTION: <br /> EDGEWATER ELK 000 D-00-LOT 47 <br /> FIRE FLOW <br /> 340.17 <br /> HYD STATIC(PSI): 117 BOR STATIC(PSI): 104 <br /> RESIDUAL(PSI): 53 HYD ELEVATION(FT): 132.13 <br /> GRA El�l ngAnF=15i rZ GRADE= P FLOW(GPM): 1,331 MODEL REPORT DATE:02/03/23 <br /> GRADE=152.5 GRADE=151.6 SYSTEM SPECIFICATIONS <br /> Z O8 BUILDING CODE: 2018 IRC with WA State Amendments C <br /> SYSTEM TYPE: NFPA 13D 2019 Wet Sprinkler System •e <br /> �z n Passive purge system without backfiow preventer > <br /> v <br /> o w O O1 SPRINKLER COVERAGE: 256 ftz Der sprinkler listino <br /> .o N 1221 SF 1220 SF 1525 SF 152$SF 122p F 1220 SF 1220 SF 1216 SF <br /> SPRINKLER SPACING: 16-0"max.between heads. <br /> D. FFi;1 PFci PA FFc' 8'-0"max.from any wall. <br /> FF`' PADc15j"� PAOk 157.E PAD;;Sj.S A 151.1 PAD>i52'8 8'-0"min.between heads. <br /> FF 150. <br /> Pq�$150.3 52.3 PAD,160.3 PA Z) 2.9 Residential fast responsependent sprinklers used throughout. N d <br /> L........... ............i ............... ........... ............ ...........i .......... HAZARD CLASSIFICATION: <br /> y v <br /> 26 Residential use throughout. u° <br /> 9 663 SF <br /> PIPING DETAILS: o <br /> Blazemaster CPVC:Aboveground wet sprinkler system throughout except as noted on the F <br /> riser detail. s <br /> SUPPLY: aC 2 n <br /> N 77°23'09" 6"circulating water main supplies 1"tap and tube to combined domestic/fire meter.1" LL m <br /> E 56.51 combined domestic/water meter supplies 1Yz"poly underground which runs to the system M Y u <br /> riser. L y N d y <br /> ............. ...... ............ .........._. ............ 109 <br /> LL a <br /> ML <br /> f... N <br /> J <br /> CPVC COMPATIBILITY: N <br /> i A list of approved products for use with Blazemaster CPVC pipe is included with the product <br /> / r__________• �___________� r___________ i I i specifications booklet.For a complete and up-to-date product search, lease go to i� <br /> / ° P P P ,- <br /> I FP'75 P FP'1�3.7 P -153.g <http://www.moorefire.com/cpvc>Moore Fire Protection is not liable for damage to CPVC c u °L <br /> ? '153 PqD_ 3.7 PF=1$4 0 PADc 51 Apc1g1 piping caused by any products which are not approved for contact with it.Information o. v u .g <br /> PO7514 ;75j.7 =1520 1{ .7 '10 3 about products approved for contact can be found with the manufacturer. y F d s a <br /> FF11$3 P' 5 F 1a 13 12 118 GENERAL NOTES AND LIABILITY <br /> Z PAD>151 4 PAD,�Sj 4 PAd=151.4 1241 SF 118 SF 1181 SF 1181 SF 1 SF 4y 'o= =m' <br /> Install CPVC piping in accordance with manufacturer's instructions and UL listing including y m <br /> N a but not limited to:hanging,vertical restraint,thermal expansion,chemical compatibility, ° `v $ <br /> a1 16 15 concealment,and protection. Horizontal CPVC pipe shall be concealed with a minimum of Z a n <br /> 12 3/8"gypsum board. All CPVC pipe shall be concealed. to x u <br /> 82 SF 1301 Sc 130j SF GRADE=153.4 GRADE=154.0 a <br /> All system piping is to be supported per manufacturer's specifications and is to be secured ` c <br /> PARCEL NO. SW GRADE=154.0 W to prevent lateral movement. Pipe is to be secured to prevent sprinkler head movement. w.5 '^ d <br /> F 5 A <br /> 00433600004801 �rn� Moore Fire Protection's warranty of work does not cover any damage due to freeze related ui a a <br /> GRADE=153.8 ^N problems. Wet piping shall be protected against temperatures below 50 degrees 999 <br /> e only with no insulation on the warm side of the a facing the heated interior. ' .. .' <br /> GRADE=154.8 ♦ 2 Fahrenheit. Insulation installed for this purpose shall be located on the cold side of the , I <br /> SW GRADE=154.0 pipe Y PP 9 N, i <br /> Coordinate with general and/or insulation contractor. All insulation to be by others. N <br /> GRADE=155.9 <br /> GRADE=155.5 a c p <br /> Moore Fire Protection shall not be responsible for the ability of the structure to adequately <br /> 22 ;23' support the fire sprinkler system or any appurtenances thereof. J <br /> 24G <br /> G - 1301 SF 7301 SF 1300 SF Owner is responsible for the periodic inspection,testing and maintenance of the water <br /> - based fire protection system(s)in accordance with the requirements of NFPA 13D Chapter <br /> ZQ 1g 19 20 21 12. : <br /> y 1180 SF 11 11 12 F1$ FFc SB PFf15 <br /> z- 61 SF 61 SF 41 SF PA1j; 6.3 PAD • .3 pAD` 8 3 • 11/z"Poly or equivalent supply brought in by others.* ... .-- .: <br /> 1T PFF7572 PF'FS PP^757 PF,y57g 156.3 �66.3 ;156.3 '�.. <br /> PA PA PADc�552 P'q�'1556 PADc155.6 11/z"combination domestic/fire sprinkler shut off valve O M M #z <br /> i by others.Must be located before the domestic tee. J s b x <br /> r••••---- ••••• r •No monitoring is required. N ti <br /> i 0 a <br /> o es # v N Uw <br /> Z ? ? ? ? �........ domesticdomestic <br /> v <br /> E 11/z"to continues to d by others An <br /> Y <br /> i domespressure-reducingIves,water softeners, • <br /> E 4 O <br /> ws 1 O leak detectors,or other devices that will deter water m u v m O <br /> .....-......' `........... ............. . <br /> G = 3 •Flow are to be on the domestic-only side of the tee. O w v o t in <br /> 8 U Brass tee top outlet to be female-threaded to d L o m <br /> " O n accommodate male threaded CPVC adapter m o v <br /> G connection. � N 0 oo w <br /> V rl Q 0 Ci 7 J <br /> C a �° 1%"PEX to domestic by others. N 3 M O N <br /> g hh"CPVC adapter with 11/2xl CPVC reducing bushing. W LL•l ;,� v Z O m m MFP scope of work to begin here. 2 E o ¢ o <br /> 1"check valve. V)Q d u ui <br /> w v <br /> r-i LU <br /> N 76°1648"E -- r ` ® 1"tee with flow switch wired to exterior bell by .--i o w o- in o w <br /> 220.10 e v others. <br /> a <br /> c e 1"x 1"x 1"tee with 1"drain valve piped to collection <br /> C, u ®cup attached to sanitary sewer,left by plumber and <br /> m sized to accommodate the system flow demand of 27 O M <br /> \\ a O d gpm• <br /> l- <br /> SITE PLAN UNDERGROUND NOTES A m � O 1"x 1"x 1/z"tee with 1h"x v4"bushing for pressure lU z a <br /> SCALE:1/16"=1'-0" 16 All underground to be by others. .r gauge.Three way valve included for pressure gauge. LLJ �i <br /> ❑A Modelled hydrant Flow location RISER SECTION KEYNOTE LEGEND LU v <br /> SCALE:1/2"=1'-0" ON ,^ > <br /> ❑B 6-in circulating water main • Part Tag LL `C) o; <br /> WARNING SIGN: STUB IN: n " <br /> 6.3.4 A warning sign,with minimum 1/4 in.letters,shall be affixed adjacent to the main *Builder to Provide 12"x 12"block out to protect piping. O �+ w <br /> ❑C Tapto 1-in combined domestic/fire fire service T ) shutoff valve and shall state the following: # Hydraulic Node Tag W <br /> U (Typical for all units 9: FLUSH TEST: ry a <br /> WARNING:The water system for this home supplies fire sprinklers that require certain *Underground installer will be required to have a flush test completed and witnessed L.- M <br /> ❑.1 1-in combined domestic/fire meter(Typical for all units) flows and pressures to fight a fire.Devices that restrict the flow or decrease the pressure before Moore Fire will hook up to the incoming supply.Underground installer to provide a O Reference Tag ' L.L v <br /> I <br /> or automatically shut off the water to the fire sprinkler system,such as water softeners, CMTC proving this test was done. LL O g <br /> filtration systems,and automatic shutoff valves,shall not be added to this system without PASSIVE PURGE SYSTEM SPECIAL NOTES: y <br /> ❑# Underground Note Tag <br /> ❑E VA-in poly combined domestic/fire underground to riser location by others*(Typical for all units) a review of the fire sprinkler system by a fire protection specialist. This is aFlow-through("passive purge")system.A 1h"female adapter will be left at the ,.,/ E <br /> remote toilet location.Plumber is to connect from adapter to toilet. ../ �: <br /> Do not remove this sign. Remote Area Tag Q <br /> Riser location-see this page for detail(Typical for all units) <br /> M <br />