Permit
K2404-019
Year
2024
Notes
SPRINKLER SYSTEM TENANT IMPROVEMENT COMMERCIAL PROJECT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: K2404-019 FIELD NOTE: SCOPE OF WORK: <br /> HANGER DETAILS 44'-1" Site Address: 8417 Evergreen Way Ste 3 <br /> --- Applicant: Columbia Fire LLC(GEN) SPRINKLER PIPING: 1)MODIFY THE EXISTING FIRE SPRINKLER SYSTEM TO ACCOMMODATE THE <br /> SCALE:NITS Applicant: <br /> T-2" Application Date:04/17/2024 1)ALL NEW ARM-OVER,SPRIG UP AND DROP TO BE SCH 40 BLACK FINISH 1" NEW WALLS AND CEILINGS. <br /> 2--l" 3'-6" Description: Sprinkler System Tenant <br /> HANGER NO.I4W Improvement Commercial Project SPRINKLER PLACEMENT: GENERAL NOTES: <br /> SAMMYSCREW 004 Review Date: 04/25/2024 1)ALL NEW SPRINKLER PENDENT TO BE IN CENTER OF 2'DIRECTION AND <br /> AND ROD Ex,. QUARTER POINT OF 4'DIRECTION FOR TX 4'TILES 1)MATERIALS INSTALLATION AND DESIGN PER NFPA 13 STANDARDS <br /> 2)ALL NEW SPRINKLER MINIMUM I'-O AWAY AND ALIGN WITH THE LIGHTING 2)ALL AREAS PROTECTED BY A WET PIPE SYSTEM MUST BE MAINTAINED AT 40 <br /> �dI °Nr (E)EL C7RIC ANEL DEGREE F TO PREVENT WATER IN PIPES FROM FREEZING BY OTHERS <br /> MY acREw GBT za EATEF FIXTURES FOR GWB CEILING UNO 3)STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER <br /> ITCHEL AREA <br /> EVERETT PIPING BY OTHERS. <br /> CT 9'-2 AFF „,.„"," SPRINKLER SPACING: <br /> Al P,.D„n Ha. IryIrFD Everett Fire Dept.Permit Review 4)ALL FIRE ALARMS,WIRING,MONITORING ARE BY OTHERS. <br /> P 1)STANDARD COVERAGE-225 SQ FT FOR LIGHT HAZARD <br /> Ra d•j Status:Approved 2 STANDARD COVERAGE-130 SQ.FOR ORDINARY HAZARD EXCLUSIONS: <br /> (E)11/4"GRVD BRANCH LINE Dz • b rn Reviewed By:KBrown ) <br /> HANGER P S— — — — — — D2 04/25/2024 1.55.05 1)FIRE WATCH OR TEMPORARY SPRINKLER PROTECTION DURING <br /> PM ELEVATIONS: CONSTRUCTION. <br /> 1 Fs 2)ACOUSTICAL CAULKING <br /> BOIL=1'-2 AFF 3)FIRESTOP CAULKING <br /> APPROVED BOIL=14'-2 AFF <br /> 4)HEAT TRACE OR INSULATION <br /> PUBLIC WORKS DEPARTMENT <br /> Hanger No.oaw 005 NEW WOMEN' S)UPRIGHT SPRINKLER PROTECTION ABOVE NONCOMBUSTIBLE CONCEALED <br /> Side Beam Bracket RESTROOM BY:Thad Newport SPACES. <br /> W°°da°E—B // P.�"'4df°"°' 006 GWB T-9 AFF CITY OF EVERETT REVIEWED FOR PERMIT 6)PAINTING SPRINKLER PIPE <br /> 7)REPAIRS OR MODIFICATIONS TO THE EXISTING SYSTEM BEYOND THE SCOPE <br /> HALLWAY • to OF WORK <br /> m <br /> GWB 8'-9 AFF D2 8)MODIFICATION OF EXISTING MAINS AND BRANCH LINES <br /> ad 50 D2 • co <br /> E 114"GRVD BRA CH LINE 9)STRUCTURAL ANALYSIS,SEISMIC INVESTIGATION <br /> Po (E) / 10)FIDE AND PE REVIEW <br /> HANGER M — — — 2r 4 . — M 11)UNDERGROUND WORK <br /> D2 0 <br /> v DESIGN CRITERIA: <br /> PER NFPA 13-2019 AND CITY OF EVERETT <br /> • D2 1)RESTROOM&HALLWAYS-LIGHT HAZARD <br /> om <br /> NEW MEWS 2)KITCHEN,SERVICE AREA-ORDINARY HAZARD GROUP I <br /> Gom RESTROOM <br /> 0 GWB 8'-5 AF <br /> o •D2 TENANT IMPROVEMENT:NO HYDRAULIC CALCULATION <br /> 0 <br /> � THIS PROJECT IS A TENANT IMPROVEMENT.THE FACILITY HAS ALREADY <br /> (E)11/4"GRVD BRANCH LINE INIFs BEEN PROTECTED BY AN EXISTING FIRE SPRINKLER SYSTEM. <br /> S— — — — — — — — — — — - MODIFICATION FOR NEW WALLS,CEILINGS,AND HVAC LAYOUT WILL BE <br /> DONE WITHOUT AFFECTING THE CAPABILITY OF THE EXISTING SYSTEM <br /> • HYDRAULIC DESIGN. <br /> TYP,NEW WALL UP TO CEILING HEIGHT, tz'-tt L <br /> CONSTRUCTION TYPE' <br /> 12'-11" NO OBSTRUCTION TO(E)UPRIGHT wo ss"• <br /> WOOD DECK,OPEN WEB TRUSSES,UNOBSTRUCTED UNO ON PLAN <br /> 0 <br /> 4'-1 V MACHINE <br /> CE <LL UNOBSTRUCTED CONSTRUCTION <br /> Lmo 3LL SEATING AREA rip ® 3d <br /> 1 sEalN6 0 28 _ 24 26 267(37• SPRINKLER DEFLECTOR-12"MAX.BELOW DECK CEILING <br /> mQ OTS MgCHINE ® __ NIPS i$ <br /> CLOUD CEILING 0- SANDMCH 31 LENDER" <br /> r.WR A'-R AFF I COOLER 36• HMO DUMP WARMER <br /> u y,by SERVICEAREA LL 32 30K 29 EFREERATORER P5 27 QIN. <br /> RENER COUNTER <br /> WA <br /> OTS r4 <br /> 11/4"GRVD BRANCH= — — — — — — — — — — d I — — — —' SERVICE AREAe <br /> q yc�t —'— 285 R STORAGE <br /> 160=CABINETS <br /> z <br /> S h �� UNDER STORAGE CABINETS UNDER STORAGE CABINETS 3 <br /> FLEXDROP DETAIL-D1 • CLOUD CEILING • • I ® 34 ADA COUNTER DISPLAY DONUTS IO-A GLAZE STATION <br /> SCALE:NTS D1 r VUR A'-R AFF D1 D1 O ��EIGHT W A.F.F. PICKUP 33 <br /> � I I <br /> ADACOUNTER <br /> TYP,ALL EXISTING QR SR011T WALL 3/•A.F.F. - <br /> ""°""""""°""""' HEIGHT34"AFF.—.—• SHORT WALL 34"A.ER♦— UPRIGHT TO BEREMAINED. <br /> EMERGENCY EGRESS PATH <br /> ♦� MIN 44"WIDE TYP. <br /> MOCHKR EVERETT <br /> U 1 1/4"GRVD BRANCH LINE— — — — — — — — — — — — — — —� — — — — — — — — seousoAO„m <br /> SERVICE AREA,SEE FLOOR PLAN PARTIAL FLOOR PLAN-SERVICE AREA <br /> FOR REFERENCE. SCALE:1/4"=r-0^ WIRO SIOP �DA EXPRES� <br /> IWIIr PaSsuSAINT) HONE 116RESTTIES <br /> 2 SHORT WALL34"A.F.F. <br /> O <br /> A <br /> FLEXDROP DETAIL-D2 m ? ' - <br /> SCALE:NTS N <br /> SEATING AREA KEY PLAN <br /> OTS SCALE:NTS <br /> 1 NORTH <br /> SCE — -- —1� — � C.do,Rd ECesino Rd % Caslno Rd EC. <br /> ENSEE <br /> Fien2 Pakeiy Culler.510 <br /> AREA PROTECTED BY EXISTING <br /> SYSTEM,NO CHANGE REQUIRED (id/O TEA <br /> EA- <br /> Plasma ODnaimn tamer <br /> O <br /> M 111 Fack In ah�e Box ItlO xFFed Meyer <br /> �O <br /> sur s•is Graenes Sunrise In,13s"a <br /> 001 002 15 <br /> aebro�aaP e° _ <br /> 6ur9er K'mg m <br /> 4' 3' 12'4" 4-10" 1, 1 3' OssMm,iecar <br /> p Wosn B Amo Derail <br /> 42'-6" <br /> f 9 Bush. a' ti <br /> MAIN ENTRANCE <br /> LEVEL1 SUITE 3-FIRE PROTECTION VICINITY MAP <br /> Sprinkler Legend <br /> SCALE:1/4"=1'-0" SCALE:NTS NORTH <br /> Symbol Manufacturer SIN Model!QuantityK-Factor Type Size Res Dose Finish Temperature Note <br /> • Reliable RA1414 F1FR55 101 5.6 Pendent % Quick Chrome 200*F RECESSED PENDENT <br /> Total M 10 <br /> ABBREVIATIONS DRAWING SYMBOLS DRAWING SYMBOLS FLEX DROP LEGEND SPRINKLER PIPE LEGEND WALL LEGEND CERTIFICATION OF COMPETENCY REVISIONS CUSTOMERINFORMATION <br /> wAYEGBRAONG D� EWMECHAryICALTEE(U-BOL) 4' 4'-0 FLEX DROP N—IFFI.—PPIPf ® .—FuuHDGmWAu NO. DATE MOCHINUT EVERETT <br /> p 4'EL P-0 FLEX DROP,ELBOW STYLE IN IN _ ____ SUPERINTENDENT:Vanhelen Lee 8417 Evergreen Wa <br /> DROPAVEOBRAONG D� EWMECHANiv.LTEE B' 6'-0FLEX DROP �����F EXISTING SPRINNER PIPE ® NEw Fuu EIGHrsoFFITHEADI F IN IN <br /> NININ INININ IN IN IN 4TRTE 1 CELL PHONE:360-567-9442 g y <br /> eoR HFLOORLIFE ryGER LOCATION P RELOCATE E%ISTING SPRINKLER 6'EL 6'EL FLEXDROP,ELBOWSTYLE aEIOCNfD f%IRTING NPE — E FIRE SPRINKLER BY E EMAIL:vannylee6l@gmaii.com <br /> 5 TOorrONt OFBrRVCNRE 4-BR 0'-0FLEX DROP BRACKET —I `------ BEI0.W FlNi CFI AT rTwsTfn R ES Y @Hmaii.COm Everett,WA 9B208 <br /> Wiliam <br /> unkle <br /> N1.1 <br /> uRE E + nrERunEBRANCH EREnRAINT LOCATION aas couPLrvG XISTING SYSTEM MPONEry ^ NEWxr DROP uNGI Matthew2-CLKEL3 <br /> V a 4960-0322-C LEVEL 3 E <br /> ., E Columbia Fire,LLC E JOB NO. 2404029501 AHJ:CITY OF EVERETT <br /> a nOM OF DECK EIEVATON E COLUMFL795NJ r DATE 04/14/24 FP <br /> o DRADD TDA-0DNNDDf Columbia Fire <br /> EXISTING SPRINKLER LEGEND j ,:?� I DESIGNER MANTIAN S. <br /> 04/16/2024 EP WA CL#COLUMFL785NJ A� <br /> 111 SaDO FindlayStraet Lee's Home Remodel <br /> PM BRIAN S. 1 OF 1 <br /> R RE4uiRm � SPRINKLER MAIN FAB • ExlsnxG ssP { �°�"�'� J Beattie,WA 98108 <br /> NM DNFSTO.SPRINKLER 5P <br /> uxo sxorm orHENWGE1 � ExISTING ssu (206)232-8569 SCALE SEE PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.