Laserfiche WebLink
Permit#: FA2308-012 <br /> Site Address: 202 Alder St <br /> Applicant: Convergint Technologies LLC • <br /> • Application Date:08/12/2023 cone rg;nt� <br /> convergInt Description Fire Alarm in portable ClassroomAdd Review Status: 1st Review by City&Peer Reviewers <br /> Review Date: 08/14/2023 <br /> 450 Shattuck Avenue South,Renton,Washington 98057 <br /> Phone:425-272-2250 Fax:425-251-0949 <br /> This dooument antl the information/depictions mntainedlshown <br /> VERETT Is the exduslve property of Convergint Technologies LLC and shall <br /> E <br /> r be handled as proprietary and oonfidential information and must be <br /> "Everett Fire ire ratumed upon request.This document cannot be reproduced by any <br /> Dept.Permit Review means without the carmen authorization of Convergint Technologies LLC. <br /> EVERETT SD - VIEW RIDGE ES Status:Approved <br /> Reviewed By:KBrown <br /> 08/14/2023 2:02:36 <br /> PM <br /> PORTABLES P3, P4, P5 <br /> 202 ALDER STREET, EVERETT, WA. 98203 <br /> SYMBOL LEGEND SCOPE OF WORK WIRE LEGEND <br /> SYM DESCRIPTION MODEL# MANUFACTURER BACK BOX THIS SCOPE OF WORK INCLUDES: ALL WIRING AND INSTALLATION METHODS SHALL BE IN COMPLIANCE WITH CURRENT RELEVANT <br /> NATIONAL AND LOCAL ELECTRICAL CODE ARTICLES AND RELATED SECTION CODE REQUIREMENTS. <br /> Nnc�« NAC POWER SUPPLY-6A BpS6A EST INCLUDED-17"H X 13"W X 3.5"D ADDITION OF THREE(3)SINGLE CLASSROOM PORTABLE BUILDINGS AT VIEW RIDGE ELEMENTARY <br /> a SIGA-CCiS MODULE SCHOOL.THE DESIGN WILL BE BASED ON ADDING TO THE EXISTING VIGILANT FIRE ALARM PANEL IN WIRING INSTALLATION NOTES: <br /> DOUBLE ACTION PULL STATION THE ADMIN BUILDING AND WILL CONSIST OF ONE(1)HEAT DETECTOR WITH A REMOTE LED,TWO(2) 'LABEL ALL ZONE WIRES WITH ZONE NUMBER TAG AND DESCRIPTION. <br /> ❑F STANDARD SIGA-278 EST SINGLE GANG,2-1/2"DEEP SMOKE DETECTORS,ONE(1)PULL STATION,ONE(1)POWER SUPPLY,TWO(2)INDOOR `LABEL ALL SIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT NUMBER TAG AND DESCRIPTION. <br /> HORN/STROBE,AND ONE(1)OUTDOOR HORN/STROBES FOR PORTABLES P4 AND P5 ONLY. `LABEL ALL NETWORK,ANNUNCIATOR AND 110 CONTROL CIRCUIT WIRING WITH CIRCUIT NUMBER <br /> O ADDRESSABLE ROR HEAT SIGA-HRD EST 4"OCTAGON BOX,1-1/2"DEEP TAG AND DESCRIPTION. <br /> wF SIGA-SB4-STANDARD BASE `VERIFY WITH OWNER AND GENERAL CONTRACTOR THAT OPEN CABLE IS ALLOWED ON SPECIFIC <br /> Q ISOLATOR MODULE SIGA-IM2 EST 4"SQUARE BOX,1-1/2"DEEP,DOUBLE GANG DESIGN CRITERIA APPLICABLE STANDARDS AND GUIDANCE: SITE.(FPL,FPLP,RISER,OR 2 HOUR RATED) <br /> COVER `WHERE REQUIRED,OUR DRAWINGS WILL NOTE WIRE OR PATHWAY REQUIRING SURVIVABILITY. <br /> 4"SQUARE BOX,1-1/2"DEEP,SINGLE GANG NFPA 72,2016 EDITION SUBSTITUTE THE RELEVANT CABLE WITH AN EQUIVALENT CABLE COMPATIBLE WITH THE MEANS OF <br /> }( REMOTE ALARM LED-CEILING SIGA-LED EST COVER 20181FC WITH WASHINGTON STATE AMENDMENTS. SURVIVABILITY.THIS OFTEN INCLUDES;CI-C OR Cl CABLE(CIRCUIT INTEGRITY),CONCRETE <br /> ENCASEMENT OR OTHER MEANS AS APPROVED BY THE AHJ.REFER TO NFPA 72 FOR FURTHER <br /> O STANDARD ADDRESSABLE SMOKE SIGA-OSD EST 4"OCTAGON BOX,1-1/2"DEEP OCCUPANCY/USE CLASSIFICATIONS: INFORMATION. <br /> SIGASB4-STANDARD BASE <br /> HORN/STROBE-CEILING MOUNT 4"SQUARE W/EST MODEL"GRSW-10" E-EDUCATIONAL NON PLENUM: SINGLE COND.: PLENUM RATED: <br /> COLOR:WHITE,MARKING:FIRE,LENS:CLEAR GCAVWF EST WIRING PLATE CIRCUIT DESCRIPTION (FPLR,FPL) (THHN,TFFN) (FPLP) <br /> DOCUMENTATION AVAILABLE TO CONVERGINT TECHNOLOGIES <br /> WEATHERPROOF HORN/STROBE-WALL MOUNT WG4WF- EST EST MODEL"449" A ZONE/INPUT CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> wp COLOR:WHITE,MARKING:FIRE,LENS:CLEAR HVMHC DYKEMAN ARCHITECTURE+DESIGN 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> ELECTRICAL SITE PLAN-VIEW RIDGE ES PG:E1.01 DATED 04/28/2023 C NAC CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> ELECTRICAL FLOOR PLAN PG:E2.01 DATED 04/28/2023 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] DESIGNER OF RECORD <br /> D MASS.NOTIFICATION NAC CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 6120UL ROEERT OR-RICIt3 <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] NICH N <br /> FIRF AIARM srsTFus <br /> E DOOR HOLDER/CONTROL CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> CONTACT INFORMATION 2COND.14 AWG [2.430][23pF/FT] [2.4301[37pF/FT] CERTIF e12- <br /> F FAN/HVAC SHUTDOWN BELDEN 5120UL (2)#14 AWG BELDEN 612OUL EXFWE Den oidnQ `, <br /> PROJECT MANAGER FIRE ALARM DESIGNER 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] FOR VERIFICATION, <br /> GLENN SMITH ROBERT RICKS G FUTURE ADA NAC BELDEN 5120UL (2)#14 AWG BELDEN 6120UL PLEASE wslr:l'NIw NICEr ORG <br /> GLEN(425y SMIT0 ROBE2T.RIC0 CIRCUIT 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> GLENN.SMITH@CONVERGINT.COM ROBERT.RICKS@CONVERGINT.COM <br /> SALES REPRESENTATIVE H PHONE CIRCUIT BELDEN 5220FL N/A BELDEN 6220FL �- <br /> PETER CAVALIERE 2 COND.16 AWG SHIELDED [3.90][65.5pF/FT] [3.850][77pF/FT] <br /> (425}272-2250 J SPEAKER CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> PETE.CAVALIERE@CONVERGINT.COM 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] 7_ <br /> L ELEVATOR CONTROL BELDEN 5120UL (2)#14 AWG BELDEN 612OUL � <br /> SHEET LIST TABLE 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> E SHEET NULBERI SHEET TITLE M AUDIO RISER BELDEN 5220FL N/A BELDEN 6220FL <br /> FA-0-1 COVER SHEET 2 COND.16 AWG SHIELDED [3.90][65.5pF/FT] [3.850][77pF/FT] <br /> FA-1-6 1 PARTIAL SITE PLAN <br /> FA-1-1 I PORTABLES P3-P5 N NETWORK COMMUNICATIONS BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> 0 FA-4-1 DEVICE DETAILS FA-4-2 DEVICE DETAILS 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> P 24VDC AUX.POWER BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> Q VESDA NET BELDEN N/A BELDEN 89841 <br /> View <br /> 2 COND.22 AWG [240][12.8pF/FPF/FT] [240][72pFIFT] <br /> R ttf�e R REMOTE LED CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> A£� O 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> � SS p f lem e n to ry S ADDRESSABLE DATA SLC LOOP BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> th2 COND.I6 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> 001 <br /> VIEW <br /> ( t / �` T1 ANALOG TWO-WAY COMM.CABLE N/A RATH RP66010001 <br /> Y 1 E Y< ty ti7 E 2COND.18 AWG NIA [2-HOURCIC] <br /> �S T2 ANALOG TWO-WAY COMM.CABLE RATH 66120 NIA N/A <br /> t� A �1!SON 2 COND.18 AWG [2-HOUR] <br /> 1Y1 1"l it f �/ 7P ANALOG TWO-WAY POWER CABLE N/A RATH R66011001 <br /> 2 COND.18 AWG WA [2-HOUR CIC] <br /> S` SW U SUPPRESSION RELEASING CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 6120UL <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] pAre <br /> VIEW RIDGE- MADISON aarz.aza <br /> W SINGLE MODE FIBER NETWORK BUDGET SMXL02/SMXH]2:15/25 dBm ISSUEDFORPERMIT <br /> 8.3p SM CONNECTOR:DUPLEX SC <br /> X MULTIMODE FIBER NETWORK BUDGET MMXVR:10 dB. <br /> 50/125p,62.5/125p OR 1D0/140p MM CONNECTOR:ST <br /> Y TWO-WAY COMMUNICATIONS BELDEN 1583A N/A BELDEN 1585A <br /> �(/ CAT5E-(4)PAIR 22 AWG <br /> ^ aka" Z FIRE/SMOKE DAMPER INTERFACE BELDEN 5120UL (2)#14 AWG BELDEN 6120UL <br /> C) ©2023 Micros Corporation©2023 Toni 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> EDOIEll, <br /> U NOTE:ALL LISTED RESISTANCE AND CAPACITANCE ARE CONDUCTOR TO CONDUCTOR.ALL PRaECT pEsraxae: RoeERr R <br /> a VICINITY MAP <br /> 1V, RESISTANCE VALUES ARE PER 1000 FEET. <br /> U <br /> Q <br /> U EVERETT SD-VIEW RIDGE ES <br /> F PORTABLES P3,P4,P5 <br /> 202 ALDER STREET <br /> to <br /> M EVERETT,WA.98203 <br /> x <br /> v <br /> N <br /> Oz COVER SHEET <br /> 0 FIRE ALARM SYSTEM <br /> z <br /> wlxD. <br /> o FA-0-1 <br /> tl <br />